DuoCor 2 DOMINATE Study
A Prospective, Multi-Center, Single-Arm Study for the Evaluation of the DuOCor 2 Ventricular Assist SysteM In Patients With AdvaNced BIventriCulAr HearT FailurE
Advanced heart failure is a life-threatening condition characterized by the inability of one or both ventricles to maintain adequate blood circulation. In such cases, medical treatments often prove ineffective, necessitating advanced treatment. Heart transplantation is the standard treatment for these patients, but it is severely limited by the shortage of donor hearts. As a result, mechanical circulatory support (MCS) devices are often employed. However, the most common form, the left ventricular assist device (LVAD), is only suitable for patients with isolated left ventricular dysfunction. This leaves a significant treatment gap for patients with biventricular failure. For this population, current options, such as total artificial hearts (TAHs) and biventricular assist devices (BiVADs), are associated with significant challenges, including high rates of adverse events and suboptimal long-term outcomes.
The DuoCor Ventricular Assist System (VAS) is a next-generation MCS device specifically developed to address this need by providing simultaneous biventricular support. It incorporates two compact, good hemocompatible blood pumps designed for implantation in both the left and right heart, controlled via a single driveline and external controller. It aims to reduce surgical complexity, improve patient mobility, and minimize complications such as thrombosis and infection.
The primary objective of this study is to evaluate the safety and efficacy of the DuoCor VAS as a treatment for advanced biventricular heart failure.
Study Overview
Status
Conditions
Intervention / Treatment
Study Type
Enrollment (Estimated)
Phase
- Not Applicable
Contacts and Locations
Study Contact
- Name: Lily Shi
- Phone Number: +86 13418601356
- Email: shixiaoli@coretechmed.com
Study Locations
-
-
-
Hanover, Germany
- Medizinische Hochschule Hannover
-
Contact:
- Jan D Schmitto
- Email: Schmitto.Jan@mh-hannover.de
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- 1. Age ≥ 18 years and ≤ 75 years
- 2. Patient is inotrope dependent, OR has a Cardiac Index (CI) < 2.2 L/min/m2, while not on inotropes
- 3. Patient has left heart failure with at least one of the following criteria:
- Left ventricular ejection fiction (LVEF) ≤ 30%;
- Pulmonary capillary wedge pressure (PCWP) > 15mmHg.
- 4. Patient has severe, irreversible biventricular heart failure and is eligible for biventricular mechanical circulatory support based on the ISHLT guideline. This includes at least two of the following hemodynamic and/or echocardiographic measurements:
- Right ventricular ejection fraction (RVEF)≤ 30%;
- Right ventricular stroke work index (RVSWI)≤ 0.25 mmHg*L/m2;
- Tricuspid annular plane systolic excursion (TAPSE)≤ 14 mm;
- Right ventricular (RV) to left ventricular (LV) end-diastolic diameter ratio> 0.72;
- Central venous pressure (CVP)> 15 mmHg;
- CVP to PCWP ratio> 0.63;
- Tricuspid insufficiency grade 2-4;
- Pulmonary artery pressure index (PAPi)< 2;
- 5. Patient or its legal representative has signed the informed consent, has full understanding of procedures and the study, and is committed to following study requirements.
Exclusion Criteria:
- 1. Known intolerance to anticoagulant or antiplatelet therapies.
- 2. Etiology of heart failure due to restrictive or constrictive physiology (e.g., hypertrophic cardiomyopathy, cardiac amyloidosis /senile or other infiltrative heart disease).
- 3. Coagulopathy defined by platelets < 100k/µl or INR ≥ 1.5 not due to anticoagulant therapy.
- 4. Technical obstacles which pose an inordinately high surgical risk, in the judgment of the investigator.
- 5. Presence of temporary mechanical circulatory support such as Impella (all types) or IABP with a duration greater than 21 days.
- 6. Presence of ECMO with a duration greater than 10 days.
- 7. Patient is implanted with durable mechanical circulatory support (LVAD or RVAD) and has refused to switch to the study device.
- 8. Patient experienced cerebrovascular accident (CVA) within 3 months of eligibility evaluation.
- 9. Presence of any one of the following risk factors for indications of severe end organ dysfunction or failure:
- Total bilirubin > 3.0 mg/dL or cirrhosis confirmed by imaging or positive biopsy;
- Glomerular filtration rate (GFR) < 30 mL/min/1.73 m2 or renal replacement therapy dependence;
- History of severe chronic obstructive pulmonary disease (COPD) defined by FEV1/FVC < 0.7, or FEV1 < 50% predicted.
- Significant peripheral vascular disease (PVD) accompanied by rest pain or extremity ulceration;
- 10. Fixed pulmonary hypertension with a most recent PVR ≥ 8 Wood units.
- 11. Severe systemic light-chain amyloidosis.
- 12. Blood stream infection within seven days. Positive blood cultures reflective of contaminants (e.g., Staphylococcus epidermidis) will not be considered an exclusion.
- 13. Sepsis
- 14. History of confirmed, untreated abdominal aortic aneurysm (AAA) or thoracic aortic aneurysm (TAA) > 5 cm in diameter.
- 15. Any condition other than HF that could limit survival to less than 24 months.
- 16. Positive pregnancy test if of childbearing potential.
- 17. Lactating mothers.
- 18. Participation in any other clinical investigation that is likely to confound study results or affect the study.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: DuoCor VAS
The DuoCor Ventricular Assist System (DuoCor VAS) to be used on patients with advanced biventricular heart failure
|
Implantation of the DuoCor Ventricular Assist System for mechanical circulatory support.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Composite of survival at 6 months post-implantation
Time Frame: 6 months
|
At 6 months post-implantation, composite of survival to transplant, recovery (defined that the removal/switch off all the pump of the DuoCor VAS due to the cardiac recovery), or survival with the device (whether with one or both pumps).
|
6 months
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Function Status as measured by Six Minute Walk Test (6MWT)
Time Frame: Baseline, Month 3, Month 6
|
The more meters a patient can walk over baseline indicates improvement in functional status.
|
Baseline, Month 3, Month 6
|
|
Functional status as measured by the New York Heart Association (NYHA) Classification
Time Frame: Baseline, Month 3, Month 6
|
NYHA class categorizes patients by the severity of their heart failure symptoms.
As the class increases, the degree of symptoms is more severe indicating worse functional status.
|
Baseline, Month 3, Month 6
|
|
Quality of Life as measured by the EuroQoL-5D-5L (EQ-5D-5L)
Time Frame: Baseline, Month 3, Month 6
|
The scores from the 5 dimensions are summed for the total score which ranges from 5 to 25 with higher scores indicating more problems and a worse quality of life.
|
Baseline, Month 3, Month 6
|
|
Quality of Life as measured by the Kansas City Cardiomyopathy Questionnaire (KCCQ)
Time Frame: Baseline, Month 3, Month 6
|
The scores range from 0 to 100.
Higher scores indicate better quality of life and fewer heart failure symptoms.
|
Baseline, Month 3, Month 6
|
|
Adverse Events
Time Frame: As they occurred, from Baseline to Month 6
|
Frequency and incidence of all anticipated Adverse Event as defined in (INTERMACS Adverse Events Definition Date: 10/11/2021)
|
As they occurred, from Baseline to Month 6
|
Collaborators and Investigators
Investigators
- Principal Investigator: Jan D Schmitto, Hannover Medical School
Study record dates
Study Major Dates
Study Start (Estimated)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
- COREMED_EU_DuoCor
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Advanced Heart Failure
-
UMC UtrechtHealth Holland; Viduet HealthNot yet recruitingAdvanced Heart FailureNetherlands
-
Tel-Aviv Sourasky Medical CenterRecruiting
-
University of MinnesotaShape Medical Systems, Inc.CompletedAdvanced Heart FailureUnited States
-
Hospital Universitario de CanariasUnknownAdvanced Heart FailureSpain
-
Abbott Medical DevicesTerminated
-
National Taiwan University HospitalUnknown
-
Carmat SASActive, not recruitingAdvanced Heart FailureFrance
-
Carmat SASuspendedAdvanced Heart FailureNetherlands, Kazakhstan
-
Abbott Medical DevicesCompletedAdvanced Heart FailureKorea, Republic of
Clinical Trials on DuoCor Ventricular Assist System
-
Shenzhen Core Medical Technology CO.,LTD.Completed
-
Abbott Medical DevicesThoratec CorporationCompletedCardiomyopathies | Ventricular Dysfunction | Heart Failure, CongestiveUnited States, Canada
-
Abbott Medical DevicesThoratec CorporationCompletedCardiomyopathies | Ventricular Dysfunction | Heart Failure, CongestiveUnited States, Canada
-
Medtronic Cardiac Rhythm and Heart FailureCompleted
-
Abbott Medical DevicesThoratec CorporationCompletedHeart FailureUnited States
-
Abbott Medical DevicesThoratec CorporationWithdrawn
-
Abbott Medical DevicesThoratec Corporation; KCRI; Center for Life Sciences; EmergoCompletedAdvanced Refractory Left Ventricular Heart FailureGermany, Australia, Austria, Canada, Czechia, Kazakhstan
-
Shenzhen Core Medical Technology CO.,LTD.RecruitingCardiogenic ShockChina
-
Shenzhen Core Medical Technology CO.,LTD.Recruiting
-
Fujian Medical UniversityRecruiting