- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT07321769
Full 3D Eye Modeling in the Diagnosis and Treatment of Lens Diseases With Eye Structures Disorders
Study Overview
Status
Conditions
Detailed Description
In patients with complex cataracts, lens opacities are often accompanied by spatial structural disorders or abnormalities involving both the lens itself and its surrounding tissues, including the anterior and posterior ocular segments. Due to the lack of precise preoperative assessment tools and standardized surgical protocols, these cases present higher surgical complexity and technical difficulty, often resulting in suboptimal outcomes. Therefore, preoperative objective quantitative analysis of the three-dimensional morphology and spatial relationships of the anterior segment, posterior segment, and the entire globe is crucial for surgical planning, prevention of complications, and postoperative visual recovery.
This study employs a retrospective research design. Using multimodal imaging systems-including anterior segment swept-source optical coherence tomography (SS-OCT), CT, B-scan ultrasound, and ultrasound biomicroscopy (UBM)-we aim to explore methods for full-eye three-dimensional reconstruction. The goal is to construct a comprehensive 3D ocular model that includes the cornea, anterior chamber, iris, angle, lens, vitreous cavity, retina, and related fundus structures.
This model will be used to comprehensively analyze morphological and spatial alterations in lens diseases associated with ocular spatial abnormalities, providing an objective quantitative description. Furthermore, the study will validate the effectiveness of this full 3D ocular model in clinical diagnosis, surgical planning, and prognosis assessment for this broad category of conditions. Ultimately, it seeks to establish objective, quantitative reference standards for the precise diagnosis and treatment of lens diseases complicated by ocular spatial structural disorders.
Study Type
Enrollment (Estimated)
Contacts and Locations
Study Contact
- Name: Wen Xu, Phd
- Phone Number: +86-13858185223
- Email: xuwen2003@zju.edu.cn
Study Locations
-
-
Zhejiang
-
Hangzhou, Zhejiang, China, 310009
- Recruiting
- Second Affiliated Hospital, Zhejiang University School of Medicine,
-
Contact:
- Wen Xu, Phd
- Phone Number: 86+ 13858185223
- Email: xuwen2003@zju.edu.cn
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
Part I:Toward 3D Modeling for Lens Disorders Associated with Congenital Anomalies
1) Diagnosed with lens disorders such as lens subluxation or deformity via imaging (slit-lamp, UBM) or clinical examination, combined with conditions such as megalocornea, microcornea, nanophthalmos, keratoconus, or iris coloboma; 2) Presence of imageable ocular structures; 3) Able to cooperate with and complete relevant examinations including B-scan ultrasound, UBM, and anterior segment SS-OCT.
- Part II: Toward 3D Modeling for Reconstructive Management of Ocular Trauma 1) Diagnosed with previous or stabilized corneal trauma, traumatic cataract, or iris injury, with or without associated vitreous traction or retinal damage; 2) Patients with open globe injuries that have been managed, with closed wounds and no endophthalmitis; 3) Able to cooperate with and complete relevant examinations including B-scan ultrasound, UBM, anterior segment SS-OCT, and CT.
- Part III:Toward 3D Modeling for IOL Spatial Positioning 1) Patients who have undergone cataract extraction with intraocular lens (IOL) implantation (in-the-bag or scleral-fixated); 2) Stable IOL position post-implantation with clear documentation of IOL parameters; 3) Able to cooperate with and complete relevant examinations including B-scan ultrasound, UBM, and anterior segment SS-OCT.
Part IV: Toward 3D Modeling for Cataracts with Iris/Pupillary Abnormalities
- Patients with iris morphological or positional abnormalities due to previous uveitis, trauma, or developmental anomalies (e.g., iris atrophy, synechiae, iridodialysis, polycoria, pupillary membrane remnants); 2) Able to cooperate with and complete relevant examinations including B-scan ultrasound, UBM, and anterior segment SS-OCT.
Part V: Toward 3D Modeling for Cataracts with Posterior Segment Diseases
1) Patients with various posterior segment vitreoretinal diseases (e.g., vitreous traction or proliferation, macular hole, epiretinal membrane), with or without anterior segment spatial structural abnormalities; 2) Able to cooperate with and complete relevant examinations including B-scan ultrasound, UBM, and anterior/posterior segment SS-OCT.
Part VI: Normal Control Group
- No significant structural ocular diseases; 2) Healthy fellow eyes of unilateral ocular trauma patients from Part II, with no notable anterior or posterior segment abnormalities; 3) Able to cooperate with and complete relevant examinations including B-scan ultrasound, UBM, anterior/posterior segment SS-OCT, and CT.
Exclusion Criteria:
Part I: Toward 3D Modeling for Lens Disorders Associated with Congenital Anomalies
1) Concurrent open globe injury or severe ocular deformity; 2) Excessive corneal opacity or severe edema resulting in inadequate image quality; 3) Severe dry eye or tear film abnormalities affecting imaging;4) Severe ocular structural deformity preventing effective 3D model reconstruction; 5) Severe systemic disease precluding tolerance of the examination; 6) Contraindications to B-scan ultrasound or UBM, conditions impairing imaging, or allergy to coupling gel.
Part II: Toward 3D Modeling for Reconstructive Management of Ocular Trauma
1) Unmanaged open globe injury or severe ocular deformity; 2) Severe systemic disease precluding tolerance of the examination; 3) Contraindications to CT imaging (e.g., metallic implants in the head/face region, pregnancy, lactation) or history of contrast medium allergy/adverse reactions.
Part III: Toward 3D Modeling for IOL Spatial Positioning
1) Unclear IOL position or documented implantation failure; 2) Corneal opacity or severe pupillary abnormality affecting imaging; 3) IOL instability due to intra- or postoperative complications preventing imaging;4) Open globe injury or severe ocular deformity; 5) Severe systemic disease precluding tolerance of the examination; 6) Contraindications to B-scan ultrasound or UBM, conditions impairing imaging, or allergy to coupling gel.
Part IV: Toward 3D Modeling for Cataracts with Iris/Pupillary Abnormalities
1) Corneal opacity or hyphema preventing imaging; 2) Severe global ocular deformity precluding imaging; 3) Severe systemic disease precluding tolerance of examination or follow-up; 4) Contraindications to B-scan ultrasound or UBM, conditions impairing imaging, or allergy to coupling gel.
Part V: Toward 3D Modeling for Cataracts with Posterior Segment Diseases
1) Severe structural deformity of both anterior and posterior segments preventing effective 3D model reconstruction; 2) Severe systemic disease precluding tolerance of examination or follow-up; 3) Contraindications to B-scan ultrasound or UBM, conditions impairing imaging, or allergy to coupling gel.
- Part VI: Normal Control Group 1) History of severe ocular trauma or ocular surgery; 2) Conditions affecting imaging quality, including corneal opacity, severe dry eye, tear film abnormalities, anterior segment disease, or significant retinal pathology; 3) Severe systemic disease precluding tolerance of the examination; 4) Contraindications to CT imaging (e.g., metallic implants in the head/face region, pregnancy, lactation) or history of contrast medium allergy/adverse reactions.
Study Plan
How is the study designed?
Design Details
Cohorts and Interventions
Group / Cohort |
|---|
|
Toward 3D Modeling for Lens Disorders Associated with Congenital Anomalies
Part I: Exploration and research on full three-dimensional modeling in the diagnosis and treatment of lens diseases with congenital developmental anomaliesa
|
|
Toward 3D Modeling for Reconstructive Management of Ocular Trauma
Part II: Exploration and research on full three-dimensional modeling for the reconstruction and treatment of ocular trauma
|
|
Toward 3D Modeling for IOL Spatial Positioning
Part III: Exploration and research on full three-dimensional modeling for the spatial positioning of pseudophakic eyes
|
|
Toward 3D Modeling for Cataracts with Iris/Pupillary Abnormalities
Part IV: Exploration and research on full three-dimensional modeling for cataract patients with iris or pupillary abnormalities
|
|
Toward 3D Modeling for Cataracts with Posterior Segment Diseases
Part V: Exploration and research on full three-dimensional modeling for the management and treatment of cataract patients with posterior segment diseases
|
|
Normal Control Group
Exploration and research on full three-dimensional modeling for individuals with no significant structural ocular diseases served as the normal control group.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Anterior Segment SS-OCT Quantitative Results
Time Frame: Preoperatively, and postoperatively at 1 week, 1 month, and 3 months
|
Quantification of the anterior segment SS-OCT imaging results
|
Preoperatively, and postoperatively at 1 week, 1 month, and 3 months
|
|
Computed tomography
Time Frame: Preoperatively, and postoperatively at 1 week, 1 month, and 3 months
|
Quantification of ocular CT imaging results
|
Preoperatively, and postoperatively at 1 week, 1 month, and 3 months
|
|
B-scan ultrasonography
Time Frame: Preoperatively, and postoperatively at 1 week, 1 month, and 3 months
|
Quantification of the B-ultrasound imaging results of the eyes
|
Preoperatively, and postoperatively at 1 week, 1 month, and 3 months
|
|
Ultrasound Biomicroscope
Time Frame: Preoperatively, and postoperatively at 1 week, 1 month, and 3 months
|
Quantification of the results of ocular UBM examination
|
Preoperatively, and postoperatively at 1 week, 1 month, and 3 months
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
IOL tilt decentration ELP
Time Frame: Preoperatively, and postoperatively at 1 week, 1 month, and 3 months
|
Using SS-OCT to record the effective position of the IOL.
|
Preoperatively, and postoperatively at 1 week, 1 month, and 3 months
|
|
Surgical Record
Time Frame: During the operation
|
Intraoperative documentation included surgical procedures, irrigation system parameters, phacoemulsification energy, and other relevant information.
|
During the operation
|
Collaborators and Investigators
Investigators
- Principal Investigator: Wen Xu, Phd, Second Affiliated Hospital, School of Medicine, Zhejiang University
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 2025-1229
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.