Lifting the Impacted Fetal Head; the Fetal Pillow and Tydeman Tube Trial (LIFT)

January 20, 2026 updated by: Guy's and St Thomas' NHS Foundation Trust
A single centre prospective observational comparison trial to compare the Tydeman Tube and Fetal Pillow, to aid delivery of the impacted fetal head at full dilatation caesarean section, and to evaluate the use of the Tydeman Tube at 7-9cm.

Study Overview

Detailed Description

An impacted fetal head is a common complication encountered in 11% of all emergency caesarean sections and 65% of those performed at full dilatation. A recent UK Obstetric Surveillance Survey (UKOSS) highlighted significant maternal and neonatal complications secondary to an impacted fetal head, with 3% of babies dying or suffering a severe injury, and 6.1% of mother's requiring admission to intensive care, emphasizing the need to evaluate techniques and new devices to aid delivery. NHS resolution's early notification scheme implicated an impacted fetal head as a contributing factor in 9% of all severe neonatal brain injuries in 2019. There is no consensus amongst clinicians on the best management of an impacted fetal head, and with exponentially rising rates of intrapartum caesarean sections, improved management tools are urgently required.

This study will compare maternal and neonatal outcomes using two devices to aid delivery of an impacted fetal head at full dilatation caesarean section (FDCS)- the Tydeman Tube, a new UK Conformity Assessed (UKCA) and European Conformity (CE) marked device, and the Fetal Pillow, an existing CE marked device used commonly in clinical practice. There will be a separate observational sub study evaluating the use of the Tydeman Tube for managing an impacted fetal head at 7-9cm dilated. The study will also explore the acceptability of both devices to women and clinicians using postnatal questionnaires.

Participants will be all women requiring a full dilatation caesarean section who meet eligibility criteria. The study will be run in two consecutive arms - firstly, obstetricians and midwives will be trained to use the Fetal Pillow. The Fetal Pillow will then be introduced into clinical practice for 3-6 months. Following this the Fetal Pillow will be removed from clinical practice. Midwives and Obstetricians will then be trained to use the Tydeman Tube, which will be introduced into clinical practice for a further 3-6 months. During the Tydeman Tube arm of the trial, women undergoing caesarean section at 7-9cm who are found to have an impacted fetal head unexpectedly at the time of caesarean section are eligible for the observational sub study. If the operating surgeon believes the Tydeman Tube is required for the clinical situation then it may be used.

The trial is a prospective observational comparison trial with an additional observational sub study. The results of this study will be used to improve understanding on the best management techniques for an impacted fetal head.

Study Type

Interventional

Enrollment (Estimated)

80

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Contact Backup

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Child
  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • Undergoing caesarean section at full dilataion for fetal pillow arm, or caesarean section at 7 or more centimetres dilated for the tydeman tube arm
  • Singleton pregnancy
  • Cephalic presentation

Exclusion Criteria:

  • Allergy to silicone rubber
  • Major congenital abnormalities
  • Major anomaly of the fetal head (i.e. large encephalocele)
  • Intrauterine death
  • Suspected chorioamnionitis
  • Active genital infection inc. Herpes Simplex Virus
  • Cervical dilatation <10cm for fetal pillow arm and <7cm for tydeman tube arm
  • Gestational age <37 weeks
  • non-cephalic presentation

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Non-Randomized
  • Interventional Model: Sequential Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Active Comparator: Fetal Pillow
The Fetal Pillow will be used for women undergoing full dilatation caesarean section who meet eligibillity criteria during the recruitment period of 3-6 months.

The Fetal Pillow is a CE marked single use sterile device. It is used in Caesarean sections performed at full dilatation. The Fetal Pillow is designed to atraumatically elevate the fetal head out of the pelvis before a caesarean section begins, making the delivery safer, easier and less traumatic. It comprises of a base plate, which is placed posteriorly in the vagina between the fetal head and the vaginal wall. It is then slowly inflated with 180mls of water via a thin tube, which aims to elevate the fetal head. It is removed at the end of the caesarean section.

Some evidence for the Fetal Pillow suggests it can reduce maternal and fetal complications from FDCS by enabling elevation of a deeply engaged head, with some studies demonstrating a reduction in uterine incision extensions, lower estimated blood lossand fewer neonatal intensinve care (NICU)admissions. However evidence is conflicting and newer randomised control trials suggest no difference in outcome when using the device.

Active Comparator: Tydeman Tube

The Tydeman tube will be used for women undergoing full dilatation caesarean section who meet eligibility criteria during the recruitment period of 3-6 months.

In addition the Tydeman Tube will be used at the discretion of the operating clinician during caesarean sections performed at 7-9cm where an impacted fetal head is encountered unexpectedly.

The Tydeman Tube is a UKCA/CE marked single use sterile device designed to aid delivery of an impacted fetal head at caesarean section. It consists of a semi-rigid wide bore silicone tube and flexible silicone cup.The tube is inserted into the vagina before or during caesarean section where an impacted fetal head is anticipated or encountered. It can be used from 7-10cm dilated. The cup fits against the baby's head. The tube is held by the assistant and used to elevate the head by pushing upwards. This disimpacts the head from the pelvis and brings it towards the surgeon's hand to enable delivery. The cup dissipates the force applied evenly over a wide area of the head which is intended to prevent fetal trauma. Once the surgeon has gained access below the head, the wide bore tube and design of the cup allows air to enter below the head during delivery to limit suction effect. Once the baby is delivered the Tydeman Tube is removed from the vagina.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Time from uterine incision to delivery
Time Frame: 4 weeks
Seconds
4 weeks

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Uterine incision to closure time
Time Frame: 4 weeks
Seconds
4 weeks
Estimated blood loss
Time Frame: 4 weeks
mLs
4 weeks
Requirement of blood products
Time Frame: 4 weeks
Yes/No
4 weeks
Volume of blood products
Time Frame: 4 weeks
Dependent on type of product
4 weeks
Presence of uterine angle extensions
Time Frame: 4 weeks
Yes/No
4 weeks
Presence of visceral injury
Time Frame: 4 weeks
Yes/No - visceral injuries may include ureter, cervix, bladder, bowel
4 weeks
Need for hysterectomy
Time Frame: 4 weeks
Yes/No
4 weeks
Presence of genital tract trauma
Time Frame: 4 weeks
Yes/No - genital tract trauma may include lacerations and haematomas
4 weeks
Admission to HDU/ITU
Time Frame: 4 weeks
Yes/No
4 weeks
Maternal death
Time Frame: 4 weeks
Yes/No
4 weeks
Length of stay
Time Frame: 4 weeks
Days
4 weeks
Wound infection
Time Frame: 4 weeks
Yes/No
4 weeks
Endometritis
Time Frame: 4 weeks
Yes/No
4 weeks
Change in maternal haemoglobin (Hb)
Time Frame: 4 weeks
Difference in measured Hb before caesarean and after caesarean
4 weeks
Presence of birth trauma to the neonate
Time Frame: 4 weeks
Yes/No - birth trauma may include intracranial haemorrhage, skull fracture, other fracture, facial nerve injury (bruising/facial nerve palsy/other nerve injury)
4 weeks
Apgar score
Time Frame: 4 weeks
Routine test taken of the newborn infant based on Appearance (colour), Pulse (heart rate), Grimace (reflexes), Activity (muscle tone) and Respiration (breathing) at 5 and 10 minutes - scored from 0-10 with lower scores indicating poor condition and need for assessment/intervention
4 weeks
Resuscitation required
Time Frame: 4 weeks
Yes/No
4 weeks
Admission to special care baby unit (SCBU) or neonatal intensive care unit (NICU)
Time Frame: 4 weeks
Yes/No
4 weeks
Length of stay in higher care
Time Frame: 4 weeks
Days
4 weeks
Arterial cord pH measurement
Time Frame: 4 weeks
Measures the acidity of a newborn's blood from the umbilical artery, reflecting fetal oxygenation and metabolic state at birth, with normal ranges around 7.18-7.38, lower values (<7.0) can signal distress, risk of neurological issues and often require neonatal observation
4 weeks
Diagnosis of hypoxic-ischaemic encephalopathy (HIE)
Time Frame: 4 weeks

Yes/No and Grading (1,2,3)

HIE is a brain injury from lack of oxygen and/or blood flow to the brain around the time of birth, affecting newborns. It is associated with potential long-term disability including cerebral palsy or developmental delay, and in severe cases death. Symptoms include seizures, poor feeding and altered alternates. It is graded as mild (Grade 1), moderate (Grade 2) and severe (Grade 3)

4 weeks
Perinatal death
Time Frame: 4 weeks
Yes/No
4 weeks
Neonatal feeding
Time Frame: 4 weeks
4 weeks
Evaluation of Fetal Pillow / Tydeman tube using Lickert scale questionnaires (clinician)
Time Frame: 4 weeks
Acceptability, ease of use, perception of impacted head and perception of ease of delivery will be assessed using Lickert scale questionnaires where participants will be asked to rate their level of agreement or feeling on a symmetrical scale, form one extreme to another (i.e. 'strongly disagree' to 'strongly agree')
4 weeks
Acceptability of Fetal Pillow / Tydeman Tube using Lickert scan questionnaires (maternal)
Time Frame: 4 weeks
Patients perception of the acceptability of the two devices will be assessed using Lickert scale questionnaires where participants will be asked to rate their level of agreement or feeling on a symmetrical scale, form one extreme to another (i.e. 'strongly disagree' to 'strongly agree')
4 weeks

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Collaborators

Investigators

  • Principal Investigator: Andrew Shennan, MD, King's College London / Guy's and St Thomas'

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

January 1, 2026

Primary Completion (Estimated)

February 1, 2027

Study Completion (Estimated)

April 1, 2027

Study Registration Dates

First Submitted

December 11, 2025

First Submitted That Met QC Criteria

January 20, 2026

First Posted (Actual)

January 28, 2026

Study Record Updates

Last Update Posted (Actual)

January 28, 2026

Last Update Submitted That Met QC Criteria

January 20, 2026

Last Verified

December 1, 2025

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Impacted Fetal Head

Clinical Trials on Fetal Pillow

Subscribe