Socket-leg Interface Movements in Transtibial Amputees (SLMinTTA)
Socket-leg Interface Movements as a Measure of Dynamic Prosthetic Fit for Transtibial Amputees: An Exploratory Study
Study Overview
Status
Conditions
Detailed Description
Transtibial prosthetic fit strongly influences user comfort, gait quality, and long term functional outcomes. Current clinical assessment methods rely primarily on subjective clinical observation and user feedback. Dynamic socket-leg interface motion (SLM) offers an objective biomechanical indicator of prosthetic fit, but existing studies are limited in sample size, measurement directions, and evaluation across different suspension systems.
This study evaluates SLMs using 3D motion capture, force sensors, and a dynamometer while participants perform three standardized task categories:
isometric rotation tasks to determine rotation resistance and torque thresholds for interface rotation; turning/rotational/pivoting walking tasks to assess functional performance and transverse plane dynamics; and treadmill walking at multiple speeds to quantify proximal-distal pistoning and gait kinematics.
Each participant is tested using three suspension system conditions (pin-lock, passive vacuum, active vacuum), starting with their preferred suspension system followed by a counterbalanced order to minimize bias. A transparent "test socket" replicating the participant's own socket allows interface visualization and marker tracking without altering the intended use of the prosthesis. The investigational device consists only of CE marked components used within their intended purpose.
Participants attend one study visit with a duration of approximately 4 to 5 hours, including prosthesis adjustment and placement, marker setup, data collection across all three task categories and with all three suspension system conditions.
The primary aim is to quantify the effects of suspension system and load conditions on SLMs and gait performance. Secondary aims assess relationships between objective SLM measures and patient reported comfort, functional ability with the prosthesis, and prosthesis satisfaction. Findings will support improved understanding of dynamic fit behavior, help characterize suspension system performance, and inform future development of objective prosthetic fitting assessment methods.
Study Type
Enrollment (Estimated)
Phase
- Not Applicable
Contacts and Locations
Study Contact
- Name: Karin Roeleveld, PhD
- Phone Number: +47 48177279
- Email: karin.roeleveld@ntnu.no
Study Contact Backup
- Name: Maria J Lequerica, MSc
- Phone Number: +47 48684299
- Email: maria.j.lequerica@ntnu.no
Study Locations
-
-
-
Trondheim, Norway, 7030
- NTNU's Movement analysis laboratory at Helgasetr
-
Contact:
- Karin Roeleveld, PhD
- Phone Number: +47 48177279
- Email: karin.roeleveld@ntnu.no
-
Contact:
- Maria J Lequerica, MSc - PhD candidate
- Phone Number: +47 48684299
- Email: maria.j.lequerica@ntnu.no
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Age ≥16 years
- Unilateral transtibial amputation
- Activity level K2-K4
- Actively using a prosthesis for ≥12 months
- Ability to understand and communicate in Norwegian (oral and written)
- Digital file of current socket model available (required for test socket fabrication)
Exclusion Criteria:
- Use of a thigh corset attached to the prosthesis
- Requirement of a walker for ambulation
- Open wounds, skin ulcers, or blisters on the residual limb
- No liner
- Missing digital socket model file
- Medical advice to avoid physical activity similar to study tasks
- Other medical conditions that may worsen with activity and have not been cleared by a healthcare professional
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Single Cohort: Three Suspension Systems
Participants with unilateral transtibial amputation will attend one study visit at the research site.
During this visit, they will complete three movement tasks-treadmill walking, overground turning, and isometric leg rotation-while using three different prosthetic suspension systems in a partly randomized order (pin lock, passive vacuum, and active vacuum).
Each of the three movement tasks will be performed with each of the three suspension systems.
Biomechanical, performance, and patient-reported outcomes will be recorded for each suspension condition.
|
Participants perform all tasks using a pin-lock suspension system applied to their test socket.
Participants perform all tasks using a passive vacuum suspension system applied to their test socket.
Participants perform all tasks using an active vacuum suspension system applied to their test socket.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Socket-Liner Motion [mm]
Time Frame: Within 1 hour after fitting the suspension system
|
Socket-liner motion is quantified using a 3D optical motion-capture system to measure the relative movement between the prosthetic socket and liner during functional activities. Motion is recorded in millimeters (mm). Typical motion values are expected to fall within the range of 0-20 mm. |
Within 1 hour after fitting the suspension system
|
|
Proximal-distal Socket-Leg Motion [mm]
Time Frame: Within 1 hour after fitting the suspension system
|
Proximal-distal Socket-Leg Motion is quantified using a 3D motion-capture system to measure the relative movement between the prosthetic socket and the remaining leg during functional activities. Motion is recorded in millimeters (mm). Typical motion values are expected to fall within the range of 0-30 mm. |
Within 1 hour after fitting the suspension system
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Torque Required to Initiate Socket-Liner Rotation [Nm]
Time Frame: Within 1 hour after fitting the suspension system
|
This measure quantifies the torque at which transverse rotation begins between the prosthetic socket and liner.
Torque is measured in Newton-meters (Nm) using a dynamometer.
|
Within 1 hour after fitting the suspension system
|
|
Step length [cm]
Time Frame: Within 1 hour after fitting the suspension system
|
Step length is quantified using a 3D motion-capture system during functional activities.
Step length is recorded in centimeters (cm).
|
Within 1 hour after fitting the suspension system
|
|
Step length asymmetry index
Time Frame: Within 1 hour after fitting the suspension system
|
Step length asymmetry will be assessed using 3D motion analysis instrumentation.
Asymmetry is computed on step length (cm) of the prosthetic and intact legs, by dividing the difference between legs by the average of both legs.
0 marks perfect symmetry and greater values higher asymmetry.
There is no maximum limit, but most values are expected to be below 1.
|
Within 1 hour after fitting the suspension system
|
|
Gait velocity [m/s]
Time Frame: Within 1 hour after fitting the suspension system
|
Gait velocity is quantified using a 3D motion-capture system during functional activities.
Gait velocity is recorded in meters per second (m/s).
|
Within 1 hour after fitting the suspension system
|
|
Patient-Reported Socket Comfort Score (SCS)
Time Frame: Within 1 hour after fitting the suspension system
|
The Socket Comfort Score is a patient-reported numerical rating scale used to assess prosthetic socket comfort. Participants rate their comfort on a 0-10 scale, where 0 represents the most uncomfortable socket imaginable and 10 represents the most comfortable socket imaginable. Comfort is evaluated for each of the three suspension conditions. For every condition, the participant provides the score immediately after completing the turning task and treadmill-walking task, both performed within 60 minutes of fitting the corresponding suspension system. |
Within 1 hour after fitting the suspension system
|
|
Perceived Functional Ability
Time Frame: Within 1 hour after fitting the suspension system
|
Perceived functional ability is assessed using a patient-reported numerical rating scale that captures the participant's subjective evaluation of how well they are able to perform functional activities with the prosthesis. Participants rate their perceived functional ability on a 0-10 scale, where 0 indicates the lowest perceived functional ability and 10 indicates the highest perceived functional ability. For each of the three suspension conditions, participants provide this rating immediately after completing the turning task and treadmill-walking task, both performed within 60 minutes of fitting the respective suspension system. |
Within 1 hour after fitting the suspension system
|
|
Prosthesis Satisfaction Score
Time Frame: Within 1 hour after fitting the suspension system
|
The Prosthesis Satisfaction Score is a patient-reported numerical rating scale used to assess overall satisfaction with the prosthetic limb. Participants rate their satisfaction on a 0-10 scale, where 0 represents the lowest possible satisfaction and 10 represents the highest possible satisfaction. For each of the three suspension conditions, participants provide this rating immediately after completing the turning task and treadmill-walking task, both performed within 60 minutes of fitting the corresponding suspension system. |
Within 1 hour after fitting the suspension system
|
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Socket-Leg rotation [degrees]
Time Frame: Within 1 hour after fitting the suspension system
|
Socket-Leg rotation is quantified using a 3D motion-capture system to measure the relative movement between the prosthetic socket and the remaining leg during functional activities. Motion is recorded in angles (degrees). Typical values are expected to fall within the range of 0-15 degrees. |
Within 1 hour after fitting the suspension system
|
|
Step length [% of bodyheight]
Time Frame: Within 1 hour after fitting the suspension system
|
Step length is quantified using a 3D motion-capture system during functional ctivities activities.
Step length is recorded in centimeters (cm) and presented as percentage of bodyheight.
|
Within 1 hour after fitting the suspension system
|
|
Knee angle [degrees]
Time Frame: Within 1 hour after fitting the suspension system
|
The knee angle is quantified using a 3D motion-capture system during the functional activities and presented in degrees as a function of the gait cycle.
|
Within 1 hour after fitting the suspension system
|
|
Hip angle [degrees]
Time Frame: Within 1 hour after fitting the suspension system
|
The hip angle is quantified using a 3D motion-capture system during the functional activities and presented in degrees as a function of the gait cycle.
|
Within 1 hour after fitting the suspension system
|
|
Foot progression angle [degrees]
Time Frame: Within 1 hour after fitting the suspension system
|
The foot progression angle is quantified using a 3D motion-capture system during the functional activities and presented in degrees.
|
Within 1 hour after fitting the suspension system
|
Collaborators and Investigators
Investigators
- Principal Investigator: Karin Roeleveld, National Taiwan Normal University
Study record dates
Study Major Dates
Study Start (Estimated)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
- 938884
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Transtibial Amputation - Unilateral
-
Massachusetts Institute of TechnologyEnrolling by invitationTranstibial Amputation - UnilateralUnited States
-
Medipol UniversityCompletedTranstibial Amputation - UnilateralTurkey
-
Mayo ClinicCompletedTranstibial Amputation - UnilateralUnited States
-
University of Colorado, DenverEunice Kennedy Shriver National Institute of Child Health and Human Development...RecruitingAmputation | Osseointegration | Transtibial Amputation - Unilateral | Bone Anchored DevicesUnited States
-
Cairo UniversityCompletedAmputation | Quadriceps Muscle Strength | Transtibial Amputation - Unilateral | Timed Up and Go | Hamstring Muscle StrengthEgypt
-
Ondokuz Mayıs UniversityCompletedActivities of Daily Living | Body Image | Participation | Lower Limb Amputation Below Knee | Transtibial Amputation - Unilateral | ICFTurkey (Türkiye)
-
MuscleMetrix, LLCRecruitingTranstibial Amputation | Transtibial AmputeeUnited States
-
Henry M. Jackson Foundation for the Advancement...University of Miami; Walter Reed National Military Medical Center; Uniformed... and other collaboratorsUnknownTranstibial Amputation | Transfemoral AmputationUnited States
-
Sheba Medical CenterCompletedUnilateral Transtibial Amputee
-
US Department of Veterans AffairsUniversity of MichiganCompletedTranstibial AmputationUnited States
Clinical Trials on Pin-Lock Suspension System
-
Ohio Willow WoodOhio State UniversityUnknownLower Limb AmputationUnited States
-
Baskent UniversityHacettepe UniversityCompletedProsthesis User | Artificial Limbs | AmputeesTurkey
-
VA Office of Research and DevelopmentUniversity of WashingtonCompletedLeg Injuries | Diabetes Complications | Amputation | Traumatic AmputationUnited States
-
Xiros LtdRecruitingAcromioclavicular; DislocationUnited Kingdom
-
Erasmus Medical CenterStichting Nuts OhraCompleted
-
Med-El CorporationCompletedHearing Loss, SensorineuralCanada, United States
-
Dhaka Dental College and HospitalBangladesh University of Engineering and TechnologyRecruitingDental Implantation | Partially Edentulous MandibleBangladesh
-
Siesta Medical, Inc.Terminated
-
IRCCS Policlinico S. MatteoUnknown