The Asia Primary Tube Versus Trab (TVT) Study (TVT)
Tutkimuksen yleiskatsaus
Tila
Tila
Ehdot
Ehdot
Interventio / Hoito
Interventio / Hoito
Yksityiskohtainen kuvaus
The objective of the Asia Primary Tube versus Trab (TVT) study is to compare the efficacy and safety of placement of an Ahmed Glaucoma Implant (AGI) (New World Medical Inc., Rancho Cucamonga, CA, USA) against trabeculectomy with mitomycin C in patients with uncontrolled glaucoma, who may or may not have had previous clear corneal cataract surgery with intraocular lens implantation, over 5 years. Outcome discrimination between the two treatment groups will be made using following parameters:
- Intraocular pressure
- Need for supplemental medical therapy
- Incidence of short and long term surgical complications and need for re-operation.
- Visual function (Visual acuity and Visual field)
Hypothesis: Glaucoma drainage implants have better surgical outcomes in terms of IOP lowering efficacy compared to trabeculectomy with mitomycin-C over 5 years in Asian patients with medically uncontrolled glaucoma.
Opintotyyppi
Opintotyyppi
Ilmoittautuminen (Odotettu)
Ilmoittautuminen
Vaihe
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskeluyhteys
Opiskeluyhteys
- Nimi: Natalia Porporato, Fellow
- Puhelinnumero: +6591378217
- Sähköposti: natalia.porporato@gmail.com
Tutki yhteystietojen varmuuskopiointi
- Nimi: Ya Ying Ooi
- Puhelinnumero: +658186 7051
- Sähköposti: ooi.ya.ying@seri.com.sg
Opiskelupaikat
-
-
-
Singapore, Singapore, 168751
- Rekrytointi
- Singapore Eye Research Institute
-
Ottaa yhteyttä:
- Serena Ting
- Puhelinnumero: (+65) 8113 5026
- Sähköposti: serena.ting.m.l@seri.com.sg
-
Päätutkija:
- Ching Lin Ho, A/Prof
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Open angle glaucoma including primary open angle glaucoma, pseudoexfoliative or pigmentary glaucoma.
- IOP > 18 mm Hg on 2 or more medications on at least 2 visits
- Informed consent given and consent form signed.
Exclusion Criteria:
- Unwilling or unable to give consent, unwilling to accept randomisation, or unable to return for scheduled protocol visits.
- Pregnant or nursing women
- No light perception vision
- Previous incisional intraocular surgery, other than uncomplicated clear corneal cataract surgery
- Previous ocular laser in study eye (keratorefractive surgery and cyclodestructive procedure), except for laser trabeculoplasty procedures (Argon Laser and Selective Laser Trabeculoplasty)
- Iris neovascularisation or proliferative retinopathy
- Primary angle closure or primary angle closure glaucoma
- Iridocorneal endothelial syndrome or anterior segment dysgenesis
- Epithelial or fibrous downgrowth
- Aphakia
- Chronic or recurrent uveitis
- Severe posterior blepharitis
- Unwilling to discontinue contact lens use after surgery
- Glaucoma secondary to penetrating keratoplasty, trauma, steroids, retinal disease/surgery or neovascular disease
- Conjunctival scarring from prior ocular surgery, trauma or cicatrizing disease precluding a superior trabeculectomy
- Need for glaucoma surgery combined with other ocular procedures (i.e. cataract surgery, penetrating keratoplasty, or retinal surgery) or anticipated need for urgent additional ocular surgery
- Advanced glaucoma with MD <-20dB
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Kaksinkertainen
Aseiden lukumäärä
Aseet ja interventiot
Osallistujaryhmä / ArmOsallistujaryhmä / Arm |
Interventio / HoitoInterventio / Hoito |
|---|---|
|
Kokeellinen: Tube implant
Ahmed Glaucoma Implant (AGI) surgery
|
Conjunctival Flap Scleral Exposure Insertion of Episcleral Plate Priming of the tube prior to AC entrance Insertion of Tube into the Anterior Chamber Suturing tube Coverage of tube
|
|
Active Comparator: Trabeculectomy
Trabeculectomy with mitomycin C surgery
|
Conjunctival Flap Mitomycin C Application Scleral Flap Paracentesis Excision of Limbal Tissue Peripheral Iridectomy Scleral Flap Closure Conjunctival Flap Closure
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Failure
Aikaikkuna: 6 months
|
Failure defined by ANY of the following criteria:
|
6 months
|
Toissijaiset tulostoimenpiteet
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
IOP
Aikaikkuna: 60 months
|
Intraocular pressure (mmHg)
|
60 months
|
|
Best Corrected Visual Acuity (BCVA)
Aikaikkuna: 60 months
|
ETDRS visual acuity chart (logMAR or equivalent)
|
60 months
|
|
Supplemental medication
Aikaikkuna: 60 months
|
Number of supplemental glaucoma medications used at Month 60
|
60 months
|
|
Adverse Events
Aikaikkuna: 60 months
|
Number of Adverse Events during the trial
|
60 months
|
Yhteistyökumppanit ja tutkijat
Sponsori
Sponsori
Yhteistyökumppanit
Yhteistyökumppanit
Tutkijat
Tutkijat
- Päätutkija: Ching Lin Ho, Singapore National Eye Centre
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Opiskelun aloitus
Ensisijainen valmistuminen (Odotettu)
Ensisijainen valmistuminen
Opintojen valmistuminen (Odotettu)
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Ensimmäinen Lähetetty
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin päivitys julkaistu
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
Muut tutkimustunnusnumerot
- R1293/99/2015
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Yhdysvalloissa valmistettu ja sieltä viety tuote
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .
Kliiniset tutkimukset Ahmed Glaucoma Implant
-
NCT04508881Valmis
-
NCT00858052Valmis
-
NCT02002637Lopetettu
-
NCT02608957Lopetettu
-
NCT02343705Lopetettu