Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

ACTivating Fat OXidation Through Capsinoids (ACTIFOX)

13 décembre 2021 mis à jour par: Jonatan Ruiz Ruiz, Universidad de Granada

The ACTivating Fat OXidation Through Capsinoids (ACTIFOX) Study

Prior evidence suggests that capsinoids ingestion may increase resting energy expenditure (EE) and fat oxidation (FATox) in humans, although whether they can modulate those parameters during exercise conditions remains poorly understood. Investigators aimed to determine the effects of dihydrocapsiate (DHC) ingestion on EE and FATox during an acute bout of aerobic exercise at FATmax intensity (the intensity that elicits maximal fat oxidation [MFO] during exercise) in overweight/obese men.

A total of 24 sedentary overweight/obese men participated in this randomized, triple-blinded, placebo-controlled, crossover trial. On the first day, participants underwent a submaximal exercise test in a cycloergometer to determine their MFO and FATmax intensity during exercise. After 72 hours had elapsed, the participants returned in 2 further days (≥ 72 hours apart) and performed a 60 min steady-state test (SST, i.e., cycling at their FATmax, constant intensity) after ingesting either 12 mg of DHC or placebo; these conditions were randomized. Respiratory gas exchange was monitored by indirect calorimetry. Serum markers concentrations (glucose, triglycerides, and non-esterified fatty acids), skin temperature, thermal perception, heart rate and perceived fatigue were assessed as secondary outcomes.

Aperçu de l'étude

Description détaillée

The study protocol and design have been approved by the Human Research Ethics Committee of the University of Granada (n°839/CEIH/2019) and the Servicio Andaluz de Salud and adhered to the tenets of the Declaration of Helsinki as revised in 2013.

Participants were asked to confirm having commuted to the research center by car, bus, tram, or motorcycle, having slept, as usual, having refrained from stimulant beverages within 24 h, and having avoided any moderate or vigorous physical activity within 24 h and 48 h (respectively).

METHODS SUMMARY

Briefly, in the first visit, sociodemographic and lifestyle data were registered, and medical screening was performed, blood samples were collected, and anthropometry and body composition measures were taken. On the second visit, the MFO during exercise and cardiorespiratory fitness (peak volume of oxygen consumption, VO2 peak) were respectively assessed through a submaximal exercise test coupled to a maximal effort test. On visits third and fourth, participants performed a 60 min steady-state exercise bout on a cycle ergometer at FATmax intensity (i.e., at the intensity at which MFO is elicited) after having ingested either 12 mg of DHC or placebo. The conditions (DHC or placebo) on visits 3 and 4 were randomized. The washout period between visits 3 and 4 was ≥72 h. Of note, all exercise tests took place at a strictly controlled temperature of 22-23 ºC, given that environmental temperature largely influences EE and FATox.

EXTENDED METHODS

MEDICAL SCREENING, SOCIODEMOGRAPHIC DATA COLLECTION, AND ANTHROPOMETRY AND BODY COMPOSITION ASSESSMENTS:

On the first visit, participants arrived at the research center at 08:00 h, in fasting conditions (8 h). Participants were informed about the study protocols details and gave their oral and written informed consent to participate in the study. Sociodemographic data and data related to participants´ dietary habits (including pungent consumption), appetite, physical activity levels, sleep, and other lifestyle habits were recorded by questionnaires (some of them filled at home). Afterward, a medical doctor conducted an anamnesis to ensure that each participant was in suitable physical conditions to participate in the study and to practice exercise. Next, participants underwent an electrocardiogram in resting conditions, which was conducted by an expert medical doctor. Systolic and diastolic blood pressure were also measured with an automatic sphygmomanometer (Omron M2; Omron Healthcare, Kyoto, Japan). These measurements were repeated on 3 consecutive occasions and the average systolic and diastolic blood pressure were calculated. Only participants presenting a non-risk medical history and normal electrocardiogram were allowed to participate in the study. Blood samples were collected from the antecubital vein in the morning (8.00-9.00 am), with subjects sitting and in resting conditions. Blood samples were collected in serum Vacutainer Tubes® (Vacutainer® SST™ II Advance tubes) and centrifuged following the manufacturer's instructions. Afterward, serum samples were sent to the hospital lab for the analysis of the analytes of interest.

Anthropometry and body composition assessments also took place on the first visit. Body weight and height were measured (no shoes, light clothing) using a model 799 Seca scale and stadiometer (Seca, Hamburg, Germany). Waist circumference was measured twice at the minimum perimeter area with a measuring tape (mm precision), and the mean value was calculated. For those participants with abdominal obesity, waist circumference was measured just above the umbilicus (horizontal plane). Body fat mass and percentage, lean body mass, and visceral adipose tissue (VAT) mas were then measured by whole-body dual-energy X-ray absorptiometry (HOLOGIC, Discovery Wi, Marlborough, MA). Body mass, lean mass, and fat mass indexes were calculated as kg/m2.

SUBMAXIMAL AND MAXIMAL EXERCISE TESTS:

On the second visit, individuals arrived at the research center normally between 15:30 and 19:00. Participants confirmed having met the above-stated pre-experimental conditions, as well as arriving in fasting conditions (5-6 h) and having followed a standardized diet that participants were instructed to follow during the previous day. Then, participants urinated, dressed as above, and entered a quiet, warm (22-23 °C) room. A submaximal-graded exercise test was performed (to determine the MFO) coupled to a maximum effort test (used to determine the VO2peak) employing an Ergoselect 200 cycle ergometer (Ergoline GmbH, Lindenstrasse, Germany). More in detail, the submaximal exercise protocol coupled to indirect calorimetry started with a 3 min stage at 20 watts (W) as a warm-up, followed by increments of 20 W every 3 min, until resting exchange ratio (RER) was ≥1 at least for 30 s (as determined by indirect calorimetry). At this point, the maximal exercise protocol started (with no interruptions), and increments of 20 W took place every 1 min until volitional exhaustion was reached, or participants had to stop because of peripherical fatigue. Of note, the cycling power values (W) at which MFO happened for each individual were used as the target exercise intensity (i.e. FATmax) for the subsequent steady-state tests. Through the exercise test, participants' perceived fatigue was assessed using a rating of the reported perceived exertion (RPE) scale, and heart rate was measured using a Polar RS800 heart-rate monitor (Polar Electro Inc., Woodbury, NY, USA). Respiratory gas exchange was monitored with a CPX Ultima CardioO2 system (Medical Graphics Corp., St Paul, MN) with a facemask model 7400 (Hans Rudolph Inc., Kansas City, MO), and a preVent™ metabolic flow sensor (Medical Graphics Corp.). Oxygen consumption (VO2) was measured using a galvanic fuel cell and carbon dioxide production (VCO2) was assessed using a non-dispersive infrared sensor. According to the manufacturer's recommendations, the gas analyzer was calibrated using standard gas concentrations immediately before each test.

STEADY-STATE EXERCISE TESTS:

On the third visit (≥72 h after the second day), and again on the fourth visit (≥72 h later to avoid carry-out effects), participants came to the laboratory and underwent the steady-state tests after the ingestion of DHC or placebo, in a randomized order. Participants arrived at the same time as on the second visit and confirmed having met exactly the same pre-experimental conditions. Participants urinated, dressed in standard clothing, and entered a quiet, warm (22-23 °C) room. A Polar RS800 heart-rate monitor was placed on their chest using a chest wrap band. Then, a set of 16 DS-1922 L Button TM wireless thermometers (Thermochron, Dallas, TX, USA) were attached to the subject's skin in different places to monitor skin temperature changes through the experiment. They were put on the forehead, left pectoralis, left elbow region, left index fingertip, left forearm, rear neck central area, right clavicula, right deltoid, right shinbone, right sub-clavicular area, right supra-clavicular area, right thigh, and upper breastbone. Afterward, participants sat and stay relaxed for 10 min (resting period, timepoint -20´), and were instructed not to move nor cross their arms and legs, and their baseline skin temperature and heart rate measures were taken. The first intravenous blood sample was collected 10 min before starting the steady-state test (timepoint -10'). Immediately 3 min after the first blood collection (timepoint -7'), participants ingested either 12 mg of DHC (4 pills 3 mg each one) or placebo. Then participants sat in the cycle ergometer where the steady-state tests would be performed, and a gas mask was put on for the gases exchange measurement. The same metabolic cart as on the second visit was used. The gas collection started 1 min before the beginning of the steady-state test (timepoint -1') with the participants sitting in the cycle ergometer without pedaling. After 1 min of gases recording in resting conditions, the steady-state test at FATmax intensity started and continued until min 60, the moment at which the test was ended. Gases exchange and heart rate were continuously monitored. At time points 15', 30', 45', and 60', blood samples were collected.

TEST SUBSTANCES: DIHYDROCAPSIATE AND PLACEBO:

Investigators employed Capsiate Gold™ soft-gel capsules from Ajinomoto®. These capsules consisted of 3 mg of purified DHC vehiculated with canola oil, modified corn starch, vegetable glycerin, carrageenan, water, disodium hydrogen phosphate, and soy lecithin. Hemicellulose powder was used as a placebo. Both DHC and hemicellulose were encapsulated by independent manufacturers and put in different containers by an independent researcher (not involved in the current study). Each container was labeled with a different code (0 or 1) so that evaluators were not aware of the administered substance - therefore preventing bias. Of note, both DHC and placebo capsules looked exactly similar to unable the identification of the content by either researchers or participants.

Type d'étude

Interventionnel

Inscription (Réel)

30

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

      • Granada, Espagne, 18007
        • Instituto Mixto Universitario Deporte y Salud - iMUDS
      • Granada, Espagne, 18007
        • Instituto Mixto Universitario Deporte y Salud

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans à 55 ans (Adulte)

Accepte les volontaires sains

Oui

Sexes éligibles pour l'étude

Homme

La description

Inclusion Criteria:

  • to be male
  • to be 18-55 years old
  • to be sedentary (<20 min moderate-to-vigorous physical activity on <3 days/week)
  • to be non-smoker
  • not to be under medication
  • to have a stable body weight over the preceding three months (<3 kg change)

Exclusion Criteria:

  • having been diagnosed with diabetes, hypertension, or any medical condition(s) that can interfere with or be aggravated by exercise
  • using medication that could affect energy metabolism
  • present a family history of CVD
  • to have an abnormal electrocardiogram, regular and high consumption of spicy foods
  • being frequently exposed to cold temperatures (e.g., indoors/outdoors workspace with low-temperatures, such as cold-storage works, ski/snow monitors, fieldworks during the winter sessions or low-temperatures areas)

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Recherche sur les services de santé
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation croisée
  • Masquage: Tripler

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Comparateur placebo: Placebo + Exercise
Placebo pills + 60 min of aerobic exercise
60 minutes of aerobic exercise (cycle-ergometer) at FATmax intensity + placebo pills (7 min before starting the aerobic exercise)
Expérimental: Dihydrocapsiate + Exercise
12 mg of dihydrocapsiate pills + 60 min of aerobic exercise
60 minutes of aerobic exercise (cycle-ergometer) at FATmax intensity + supplementation with 12 mg of dihydrocapsiate (7 min before starting the aerobic exercise)

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Délai
Change in energy expenditure (kcal/day) by indirect calorimetry (CPX Ultima CardioO2 system)
Délai: It will be continuously measured through the 60 minutes-bout of aerobic exercise at FATmax intensity
It will be continuously measured through the 60 minutes-bout of aerobic exercise at FATmax intensity
Change in fat oxidation (g/min) by indirect calorimetry (CPX Ultima CardioO2 system)
Délai: It will be continuously measured through the 60 minutes-bout of aerobic exercise at FATmax intensity
It will be continuously measured through the 60 minutes-bout of aerobic exercise at FATmax intensity

Mesures de résultats secondaires

Mesure des résultats
Délai
Change in serum levels of glucose (mg/dL) by automated analyzer (Beckman Coulter)
Délai: It will be measured at timepoints 0, 15, 30, 45 and 60 minutes, of the 60 minutes-bout of aerobic exercise at FATmax intensity
It will be measured at timepoints 0, 15, 30, 45 and 60 minutes, of the 60 minutes-bout of aerobic exercise at FATmax intensity
Change in serum levels of triglycerides (mg/dL) by automated analyzer (Beckman Coulter)
Délai: It will be measured at timepoints 0, 15, 30, 45 and 60 minutes, of the 60 minutes-bout of aerobic exercise at FATmax intensity
It will be measured at timepoints 0, 15, 30, 45 and 60 minutes, of the 60 minutes-bout of aerobic exercise at FATmax intensity
Change in serum levels of non-esterified fatty acids (mmol/L) by automated analyzer (Beckman Coulter)
Délai: It will be measured at timepoints 0, 15, 30, 45 and 60 minutes, of the 60 minutes-bout of aerobic exercise at FATmax intensity
It will be measured at timepoints 0, 15, 30, 45 and 60 minutes, of the 60 minutes-bout of aerobic exercise at FATmax intensity
Change in skin temperature (ºC) by iButtons wireless thermometers
Délai: It will be continuously measured through the 60 minutes-bout of aerobic exercise at FATmax intensity
It will be continuously measured through the 60 minutes-bout of aerobic exercise at FATmax intensity
Change in thermal perception (unitless) by ASHRAE scales
Délai: It will be measured every 15 minutes of the 60 minutes-bout of aerobic exercise at FATmax intensity
It will be measured every 15 minutes of the 60 minutes-bout of aerobic exercise at FATmax intensity
Change in rated perceived exertion (unitless) by RPE scales
Délai: It will be measured every 5 minutes of the 60 minutes-bout of aerobic exercise at FATmax intensity
It will be measured every 5 minutes of the 60 minutes-bout of aerobic exercise at FATmax intensity

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

3 juin 2019

Achèvement primaire (Réel)

13 mars 2020

Achèvement de l'étude (Réel)

1 juillet 2020

Dates d'inscription aux études

Première soumission

12 novembre 2021

Première soumission répondant aux critères de contrôle qualité

13 décembre 2021

Première publication (Réel)

14 décembre 2021

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

14 décembre 2021

Dernière mise à jour soumise répondant aux critères de contrôle qualité

13 décembre 2021

Dernière vérification

1 décembre 2021

Plus d'information

Termes liés à cette étude

Termes MeSH pertinents supplémentaires

Autres numéros d'identification d'étude

  • 839/CEIH/2019

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

produit fabriqué et exporté des États-Unis.

Oui

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

Essais cliniques sur Surpoids et obésité

Essais cliniques sur Placebo + Exercise

3
S'abonner