Prestazioni visive con le lenti intraoculari (IOL) Clareon® Vivity®
Valutazione dell'impatto dell'astigmatismo residuo sulla prestazione visiva con Clareon Vivity
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: Alcon Call Center
- Numero di telefono: 1-888-451-3937
- Email: alcon.medinfo@alcon.com
Luoghi di studio
-
-
Michigan
-
Bloomfield Hills, Michigan, Stati Uniti, 48302
- Grosinger, Spigelman & Grey Eye Surgeons, P.C
-
-
Texas
-
Dallas, Texas, Stati Uniti, 75243
- Key-Whitman Eye Center
-
Sugar Land, Texas, Stati Uniti, 77478
- Berkeley Eye Center
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Criteri di inclusione:
- In grado di comprendere e firmare un modulo di consenso informato approvato dal Comitato di revisione dell'istituto;
- Disponibili e in grado di partecipare a tutte le visite di studio programmate come richiesto dal protocollo;
- Impiantato con le IOL dello studio in entrambi gli occhi almeno 4 mesi prima della partecipazione allo studio;
- BCDVA pari a 0 logMAR o migliore in ciascun occhio.
Criteri di esclusione:
- Astigmatismo residuo maggiore o uguale a 1,00 D;
- Condizioni oculari clinicamente significative come specificato nel protocollo;
- Storia di interventi chirurgici oculari diversi dalle incisioni rilassanti limbari
- Potrebbero essere applicati altri criteri di esclusione specificati dal protocollo.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Clareon Vivity/Vivity Toric
Precedente impianto in entrambi gli occhi con IOLs alla visione estesa estesa Torica Clareon Vivity/Vivity, con impianto precedente definito almeno 4 mesi prima della partecipazione allo studio.
|
Lente intraoculare a visione estesa impiantata nella sacca capsulare dell'occhio durante l'intervento di cataratta.
Le IOL sono destinate all'uso a lungo termine per tutta la vita del paziente affetto da cataratta.
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Mean Difference in Monocular Best Corrected Distance Visual Acuity (BCDVA) (4 Meters) Before and After Inducing 1.0 Diopter (D) Astigmatism - WTR
Lasso di tempo: Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
BCDVA was assessed with best refractive correction in place at a distance of 4 meters (m) using Early Treatment Diabetic Retinopathy Study (ETDRS) letter charts.
Trial lenses were used to induce 1.0 diopter (D) of astigmatism with-the-rule (WTR), defined as -0.50/+1.00
D at approximately 180 degrees on the optical axis.
VA was measured in the first implanted eye in logarithm minimum angle of resolution (logMAR), with a lower logMAR value indicating better visual acuity.
The change in VA before and after inducing astigmatism is reported, with a positive value representing a decline in VA.
No hypothesis testing was prespecified for this co-primary endpoint.
|
Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
|
Mean Difference in Monocular Distance Corrected Intermediate Visual Acuity (DCIVA) (66 Centimeters) Before and After Inducing 1.0 D Astigmatism - WTR
Lasso di tempo: Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
DCIVA was assessed with distance correction in place (plus or minus power) at a distance of 66 centimeters (cm) from the spectacle plane using ETDRS letter charts.
Trial lenses were used to induce 1.0 D of astigmatism with-the-rule (WTR), defined as -0.50/+1.00
D at approximately 180 degrees on the optical axis.
VA was measured in the first implanted eye in logarithm minimum angle of resolution (logMAR), with a lower logMAR value indicating better visual acuity.
The change in VA before and after inducing astigmatism is reported, with a positive value representing a decline in VA.
No hypothesis testing was prespecified for this co-primary endpoint.
|
Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
|
Mean Difference in Monocular Distance Corrected Near Visual Acuity (DCNVA) (40 cm) Before and After Inducing 1.0 D Astigmatism - WTR
Lasso di tempo: Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
DCNVA was assessed with distance correction in place (plus or minus power) at a distance of 40 cm from the spectacle plane using ETDRS letter charts.
Trial lenses were used to induce 1.0 D of astigmatism WTR, defined as -0.50/+1.00
D at approximately 180 degrees on the optical axis.VA was measured in the first implanted eye in logarithm minimum angle of resolution (logMAR), with a lower logMAR value indicating better visual acuity.
The change in VA before and after inducing astigmatism is reported, with a positive value representing a decline in VA.
No hypothesis testing was prespecified for this co-primary endpoint.
|
Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
|
Mean Difference in Monocular Best Corrected Distance Visual Acuity (BCDVA) (4 Meters) Before and After Inducing 1.0 Diopter (D) Astigmatism - ATR
Lasso di tempo: Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
BCDVA was assessed with best refractive correction in place at a distance of 4 m using ETDRS letter charts.
Trial lenses were used to induce 1.0 D of astigmatism against the rule (ATR), defined as -0.50/+1.00
D at approximately 90 degrees on the optical axis.
VA was measured in the first implanted eye in logarithm minimum angle of resolution (logMAR), with a lower logMAR value indicating better visual acuity.
The change in VA before and after inducing astigmatism is reported, with a positive value representing a decline in VA.
No hypothesis testing was prespecified for this co-primary endpoint.
|
Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
|
Mean Difference in Monocular Distance Corrected Intermediate Visual Acuity (DCIVA) (66 Centimeters) Before and After Inducing 1.0 D Astigmatism.- ATR
Lasso di tempo: Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
DCIVA was assessed with distance correction in place (plus or minus power) at a distance of 66 cm from the spectacle plane using ETDRS letter charts.
Trial lenses were used to induce 1.0 D of astigmatism ATR, defined as -0.50/+1.00
D at approximately 90 degrees on the optical axis.
VA was measured in the first implanted eye in logarithm minimum angle of resolution (logMAR), with a lower logMAR value indicating better visual acuity.
The change in VA before and after inducing astigmatism is reported, with a positive value representing a decline in VA.
No hypothesis testing was prespecified for this co-primary endpoint.
|
Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
|
Mean Difference in Monocular Distance Corrected Near Visual Acuity (DCNVA) (40 cm) Before and After Inducing 1.0 D Astigmatism - ATR
Lasso di tempo: Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
DCNVA was assessed with distance correction in place (plus or minus power) at a distance of 40 cm from the spectacle plane using ETDRS letter charts.
Trial lenses were used to induce 1.0 D of astigmatism ATR, defined as -0.50/+1.00
D at approximately 90 degrees on the optical axis.
VA was measured in the first implanted eye in logarithm minimum angle of resolution (logMAR), with a lower logMAR value indicating better visual acuity.
The change in VA before and after inducing astigmatism is reported, with a positive value representing a decline in VA.
No hypothesis testing was prespecified for this co-primary endpoint.
|
Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Direttore dello studio: Clinical Trial Lead, Surgical CRD, Alcon Research, LLC
Pubblicazioni e link utili
Collegamenti utili
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- ILE632-C003
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .