Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Extent of ILM Removal and Its Impact on Outcomes of MH Surgery

5 gennaio 2016 aggiornato da: Samsung Medical Center

Extent of Internal Limiting Membrane Removal and Its Impact on Outcomes of Macular Hole Surgery

Eligible patients who were scheduled for surgery for idiopathic macular hole (MH) were equally randomized to small extent group or large extent group depending on the extent of internal limiting membrane (ILM) to be removed. The ILM was peeled in round shape with the radius of either 0.75-disc diameter or 1.5-disc diameter according to the group. The primary analysis was conducted to identify the difference of functional and anatomical outcomes between the two groups. Subsequent analysis was performed to reveal the relationship between the functional and anatomical outcomes.

Panoramica dello studio

Stato

Completato

Condizioni

Descrizione dettagliata

This randomized clinical trial was performed at a single center. Patients who were scheduled for surgery for idiopathic macular hole (MH) were enrolled. Eligible patients were equally randomized to small extent group or large extent group depending on the extent of ILM to be removed. Random numbers were generated through computerized block-randomization.

A standard 3-port pars plana vitrectomy was performed by a single surgeon using 23-gauge vitrectomy system, with a 1-step scleral tunnel incision. After posterior vitreous detachment was achieved, peeling of the ILM was performed by an end gripping forceps with the assistance of indocyanine green dye. The ILM was peeled in round shape with the radius of either 0.75-disc diameter or 1.5-disc diameter centering at the center of the MH according to the pre-assigned group. This was followed by a complete fluid-gas exchange, and all patients were encouraged to maintain a face-down position for at least 5 days postoperatively.

Postoperative measurements of BCVA and M-score were conducted at 2- and 6-month follow-up visits by independent masked observers. The first postoperative SD-OCT scanning was usually conducted at 1 to 2 weeks after operation according to the intraocular gas status. Then, OCT scans were conducted at follow-up visits 2, and 6 months postoperatively. The same experienced examiner conducted all the OCT scans on all subjects.

Comparison of anatomical closure, BCVA, M-score, Δ BCVA, and Δ M-score were primarily performed between the two groups. Then, the parameters measured from OCT scans with changes in ETDRS visual acuity and M-score were analyzed.

Tipo di studio

Interventistico

Iscrizione (Effettivo)

65

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

20 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • idiopathic macular hole

Exclusion Criteria:

  • macular hole associated with other causative diseases

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Separare

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Comparatore attivo: Small Extent Group (SG)
Patients who were scheduled for surgery for idiopathic macular hole were randomly assigned to the SG. The small-extent peeling was performed in SG.
The internal limiting membrane was peeled in round shape with the radius of 0.75-disc diameter radius (1.5-disc diameter in total) centering at the center of the macular hole.
Comparatore attivo: Large Extent Group (LG)
Patients who were scheduled for surgery for idiopathic macular hole were randomly assigned to the LG. The large-extent peeling was performed in LG.
The internal limiting membrane was peeled in round shape with the radius of 1.5-disc diameter radius (3.0-disc diameter in total) centering at the center of the macular hole.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Lasso di tempo
Degree of foveal elongation
Lasso di tempo: postoperative 6months
postoperative 6months

Misure di risultato secondarie

Misura del risultato
Lasso di tempo
metamorphopsia
Lasso di tempo: 6months
6months

Altre misure di risultato

Misura del risultato
Lasso di tempo
alterazione dell'acuità visiva
Lasso di tempo: 6 mesi
6 mesi

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Investigatore principale: Kunho Bae, MD, Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio

1 luglio 2013

Completamento primario (Effettivo)

1 ottobre 2015

Completamento dello studio (Effettivo)

1 novembre 2015

Date di iscrizione allo studio

Primo inviato

9 dicembre 2013

Primo inviato che soddisfa i criteri di controllo qualità

11 dicembre 2013

Primo Inserito (Stima)

12 dicembre 2013

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Stima)

7 gennaio 2016

Ultimo aggiornamento inviato che soddisfa i criteri QC

5 gennaio 2016

Ultimo verificato

1 gennaio 2016

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • 2013-07-083

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su small-extent peeling

Sottoscrivi