Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Extent of ILM Removal and Its Impact on Outcomes of MH Surgery

5 de janeiro de 2016 atualizado por: Samsung Medical Center

Extent of Internal Limiting Membrane Removal and Its Impact on Outcomes of Macular Hole Surgery

Eligible patients who were scheduled for surgery for idiopathic macular hole (MH) were equally randomized to small extent group or large extent group depending on the extent of internal limiting membrane (ILM) to be removed. The ILM was peeled in round shape with the radius of either 0.75-disc diameter or 1.5-disc diameter according to the group. The primary analysis was conducted to identify the difference of functional and anatomical outcomes between the two groups. Subsequent analysis was performed to reveal the relationship between the functional and anatomical outcomes.

Visão geral do estudo

Descrição detalhada

This randomized clinical trial was performed at a single center. Patients who were scheduled for surgery for idiopathic macular hole (MH) were enrolled. Eligible patients were equally randomized to small extent group or large extent group depending on the extent of ILM to be removed. Random numbers were generated through computerized block-randomization.

A standard 3-port pars plana vitrectomy was performed by a single surgeon using 23-gauge vitrectomy system, with a 1-step scleral tunnel incision. After posterior vitreous detachment was achieved, peeling of the ILM was performed by an end gripping forceps with the assistance of indocyanine green dye. The ILM was peeled in round shape with the radius of either 0.75-disc diameter or 1.5-disc diameter centering at the center of the MH according to the pre-assigned group. This was followed by a complete fluid-gas exchange, and all patients were encouraged to maintain a face-down position for at least 5 days postoperatively.

Postoperative measurements of BCVA and M-score were conducted at 2- and 6-month follow-up visits by independent masked observers. The first postoperative SD-OCT scanning was usually conducted at 1 to 2 weeks after operation according to the intraocular gas status. Then, OCT scans were conducted at follow-up visits 2, and 6 months postoperatively. The same experienced examiner conducted all the OCT scans on all subjects.

Comparison of anatomical closure, BCVA, M-score, Δ BCVA, and Δ M-score were primarily performed between the two groups. Then, the parameters measured from OCT scans with changes in ETDRS visual acuity and M-score were analyzed.

Tipo de estudo

Intervencional

Inscrição (Real)

65

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

20 anos e mais velhos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  • idiopathic macular hole

Exclusion Criteria:

  • macular hole associated with other causative diseases

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Solteiro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Comparador Ativo: Small Extent Group (SG)
Patients who were scheduled for surgery for idiopathic macular hole were randomly assigned to the SG. The small-extent peeling was performed in SG.
The internal limiting membrane was peeled in round shape with the radius of 0.75-disc diameter radius (1.5-disc diameter in total) centering at the center of the macular hole.
Comparador Ativo: Large Extent Group (LG)
Patients who were scheduled for surgery for idiopathic macular hole were randomly assigned to the LG. The large-extent peeling was performed in LG.
The internal limiting membrane was peeled in round shape with the radius of 1.5-disc diameter radius (3.0-disc diameter in total) centering at the center of the macular hole.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Prazo
Degree of foveal elongation
Prazo: postoperative 6months
postoperative 6months

Medidas de resultados secundários

Medida de resultado
Prazo
metamorphopsia
Prazo: 6months
6months

Outras medidas de resultado

Medida de resultado
Prazo
alteração na acuidade visual
Prazo: 6 meses
6 meses

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Investigador principal: Kunho Bae, MD, Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo

1 de julho de 2013

Conclusão Primária (Real)

1 de outubro de 2015

Conclusão do estudo (Real)

1 de novembro de 2015

Datas de inscrição no estudo

Enviado pela primeira vez

9 de dezembro de 2013

Enviado pela primeira vez que atendeu aos critérios de CQ

11 de dezembro de 2013

Primeira postagem (Estimativa)

12 de dezembro de 2013

Atualizações de registro de estudo

Última Atualização Postada (Estimativa)

7 de janeiro de 2016

Última atualização enviada que atendeu aos critérios de controle de qualidade

5 de janeiro de 2016

Última verificação

1 de janeiro de 2016

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • 2013-07-083

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Ensaios clínicos em Buracos maculares

Ensaios clínicos em small-extent peeling

3
Se inscrever