Respiratory Variability in Aortic Blood Velocity Measured by Suprasternal View as an Indicator of Fluid Responsiveness (SUPRA-PAM)
1 juni 2016 bijgewerkt door: Hospices Civils de Lyon
Respiratory changes in aortic blood velocity have been described as an indicator of fluid responsiveness when measured in the left ventricular outflow tract by trans esophageal echography.
A threshold value of 12% allowed discrimination between responders and nonresponders with a sensitivity of 100% and a specificity of 89%.
The suprasternal window is already used to measure cardiac output.
The primary endpoint of this study is to determine the predictive value of the respiratory variability in aortic blood velocity measured by suprasternal view (∆VpicSS) as an indicator of fluid responsiveness.
The secondary endpoint is to compare maximum velocity and velocity time integral measured by suprasternal and transthoracic view.
Studie Overzicht
Toestand
Voltooid
Conditie
Interventie / Behandeling
Studietype
Ingrijpend
Inschrijving (Werkelijk)
62
Fase
- Niet toepasbaar
Contacten en locaties
In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.
Studie Locaties
-
-
-
Lyon, Frankrijk, 69002
- Hôpital de la Croix-Rousse, Hospices Civils de Lyon
-
-
Deelname Criteria
Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
18 jaar en ouder (Volwassen, Oudere volwassene)
Accepteert gezonde vrijwilligers
Nee
Geslachten die in aanmerking komen voor studie
Allemaal
Beschrijving
Inclusion Criteria:
- Age more than 18 years
- American Society of Anesthesiologists (ASA) score 1 or 2
- General Anesthesia with mechanical ventilation
- General Surgery
Exclusion Criteria:
- Arrhythmia
- Spontaneous breathing activity
- Significant valvular disease
Studie plan
Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Diagnostisch
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
---|---|
Experimenteel: Fluid challenge with 250 ml of Ringer Lactate
|
Fluid challenge with 250 ml of Ringer Lactate over less than 2 minutes, intra-venous, help by a syringe of 50 ml. Measure of peak velocity before and after the fluid challenge |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
---|---|---|
Percentage of cardiac flow variability
Tijdsspanne: At day 1(before surgery)
|
Percentage of cardiac flow variability between the 2 echographic measures.
Echographic measures will be realized a first time before fluid challenge by suprasternal view and a second time after the fluid challenge by suprasternal view.
|
At day 1(before surgery)
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
---|---|---|
Comparison of percentage of cardiac flow variability between transthoracic and suprasternal views
Tijdsspanne: At day 1(before surgery)
|
Echographic measures will be realized a first time before fluid challenge by transthoracic and by suprasternal view and a second time after the fluid challenge by transthoracic and by suprasternal view.
|
At day 1(before surgery)
|
Medewerkers en onderzoekers
Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.
Sponsor
Onderzoekers
- Hoofdonderzoeker: Pauline Devauchelle, MD, Hopital de la Croix-Rousse
Studie record data
Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.
Bestudeer belangrijke data
Studie start
1 april 2015
Primaire voltooiing (Werkelijk)
1 maart 2016
Studie voltooiing (Werkelijk)
1 maart 2016
Studieregistratiedata
Eerst ingediend
27 mei 2016
Eerst ingediend dat voldeed aan de QC-criteria
1 juni 2016
Eerst geplaatst (Schatting)
7 juni 2016
Updates van studierecords
Laatste update geplaatst (Schatting)
7 juni 2016
Laatste update ingediend die voldeed aan QC-criteria
1 juni 2016
Laatst geverifieerd
1 mei 2016
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Andere studie-ID-nummers
- 69HCL14-0408
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .
Klinische onderzoeken op Cardiovasculair systeem
-
Advanced BionicsVoltooidErnstig tot zeer ernstig gehoorverlies | bij volwassen gebruikers van Advanced Bionics HiResolution™ Bionic Ear SystemVerenigde Staten
-
Brigham and Women's HospitalBiohaven Pharmaceuticals, Inc.VoltooidMeervoudige systeematrofie | Multiple systeematrofie, Parkinson-variant (aandoening) | Meervoudige systeematrofie, cerebellaire variant | Multiple System Atrophy (MSA) met orthostatische hypotensieVerenigde Staten
-
Theravance BiopharmaVoltooidZiekte van Parkinson | Orthostatische hypotensie | Neurogene orthostatische hypotensie | Hypotensie, orthostatisch | Puur autonoom falen | Multiple System Atrophy (MSA) met orthostatische hypotensie | Puur autonoom falen met orthostatische hypotensie | Ziekte van Parkinson met orthostatische hypotensieVerenigde Staten
Klinische onderzoeken op Fluid challenge with 250 ml of Ringer Lactate
-
McGill University Health Centre/Research Institute...OnbekendWerkelijk verminderd vloeistofvolume