- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT05906225
Anesthesie en EEG-discontinuïteit bij zuigelingen
De impact van elektro-encefalogram (EEG) - geleide inhalatie-anesthesiecontrole op het optreden van EEG-discontinuïteit bij zuigelingen: een prospectieve gerandomiseerde gecontroleerde studie
This study is a randomized controlled trial to evaluate whether EEG-guided calibration of inhalation agents can reduce occurrence of EEG discontinuity in infants during general anesthesia.
Studie Overzicht
Toestand
Interventie / Behandeling
Gedetailleerde beschrijving
This is a study for comparison of incidence of EEG discontinuity during general anesthesia using sevoflurane. EEG guidance group will receive calibration of fraction of inhalational sevoflurane according to components of slow wave and delta wave of raw EEG. Control group will receive conventional management of anesthesia according to vital signs.
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Contacten en locaties
Studiecontact
- Naam: Sang-Hwan Ji, M.D., Ph.D.
- Telefoonnummer: +82-2-2072-3661
- E-mail: taepoongshin@gmail.com
Studie Locaties
-
-
Other
-
Seoul, Other, Zuid -Korea, 03080
- Werving
- Seoul National University Hospital
-
Contact:
- Sang-Hwan Ji, M.D., M.S.
- Telefoonnummer: +82-2-2072-3661
- E-mail: taepoongshin@gmail.com
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Infants who were born as full-term (>37 weeks postconception) and are equal to or less than 12 month old who were scheduled to undergo surgery under general anesthesia using inhalation agents.
- Belongs to American Society of Anesthesiologists Physical Status 1 or 2
Exclusion Criteria:
- Infants who were born less than 37 weeks postconception or has history of mechanical ventilation immediately after birth
- Presence of any genetic disease, chromosomal anomaly or congenital anomaly that can affect brain development
- Presence of any disease or disability in central nervous system
- History of trauma at head or surgery on brain
- History of hypersensitivity to any anesthetic agents
- Status of sedation or endotracheal intubation before induction of anesthesia
- Inability to attach probes for EEG monitoring
- Expectation of operation time as less than 5 minutes
- Other conditions that researchers regard as inappropriate for enrollment
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Preventie
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Verdrievoudigen
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Electroencephalogram
Adjustment of concentration of sevoflurane according to EEG |
Monitoring of electroencephalogram via Sedline probe by MASIMO corporation. Adjust concentration of inhalational sevoflurane during anesthesia, according to component of slow&delta wave and alpha wave, so that slow/delta oscillation (with or without alpha oscillation) is maintained. |
|
Actieve vergelijker: Conventional
Adjustment of concentration of sevoflurane according to vital signs |
Adjust concentration of inhalational sevoflurane during anesthesia, according to vital signs, so that mean blood pressure and heart rate are maintained between 80% and 120% of baseline values measured at ward before anesthesia. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
EEG discontinuity
Tijdsspanne: From start of anesthesia to end of anesthesia, Less than 24 hours
|
Incidence of EEG discontinuity (EEG amplitudes < 25uV for more than 2 seconds) |
From start of anesthesia to end of anesthesia, Less than 24 hours
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Total duration of EEG discontinuity
Tijdsspanne: From start of anesthesia to end of study, Less than 24 hours
|
Total sum of duration of EEG discontinuity |
From start of anesthesia to end of study, Less than 24 hours
|
|
Significant isoelectric EEG
Tijdsspanne: From start of anesthesia to end of study, Less than 24 hours
|
Incidence of significant isoelectric EEG (EEG amplitudes < 10uV for more than 2 seconds) |
From start of anesthesia to end of study, Less than 24 hours
|
|
EtSev
Tijdsspanne: From start of anesthesia to end of study, Less than 24 hours
|
Mean end-tidal sevoflurane concentration during anesthesia |
From start of anesthesia to end of study, Less than 24 hours
|
|
SEF
Tijdsspanne: From start of anesthesia to end of study, Less than 24 hours
|
Mean spectral edge frequency value during anesthesia |
From start of anesthesia to end of study, Less than 24 hours
|
|
PSi
Tijdsspanne: From start of anesthesia to end of study, Less than 24 hours
|
Mean patient state index value during anesthesia |
From start of anesthesia to end of study, Less than 24 hours
|
|
Mean blood pressure
Tijdsspanne: From start of anesthesia to end of study, Less than 24 hours
|
Mean blood pressure values during anesthesia measured every 2.5 minutes |
From start of anesthesia to end of study, Less than 24 hours
|
|
Heart rate
Tijdsspanne: From start of anesthesia to end of study, Less than 24 hours
|
Heart rate values during anesthesia measured every 2.5 minutes |
From start of anesthesia to end of study, Less than 24 hours
|
Medewerkers en onderzoekers
Onderzoekers
- Hoofdonderzoeker: Ji-Hyun Lee, M.D., Ph.D., Seoul National University Hospital
Publicaties en nuttige links
Algemene publicaties
- Brown EN, Lydic R, Schiff ND. General anesthesia, sleep, and coma. N Engl J Med. 2010 Dec 30;363(27):2638-50. doi: 10.1056/NEJMra0808281. No abstract available.
- Purdon PL, Sampson A, Pavone KJ, Brown EN. Clinical Electroencephalography for Anesthesiologists: Part I: Background and Basic Signatures. Anesthesiology. 2015 Oct;123(4):937-60. doi: 10.1097/ALN.0000000000000841.
- Avidan MS, Zhang L, Burnside BA, Finkel KJ, Searleman AC, Selvidge JA, Saager L, Turner MS, Rao S, Bottros M, Hantler C, Jacobsohn E, Evers AS. Anesthesia awareness and the bispectral index. N Engl J Med. 2008 Mar 13;358(11):1097-108. doi: 10.1056/NEJMoa0707361.
- Cornelissen L, Bergin AM, Lobo K, Donado C, Soul JS, Berde CB. Electroencephalographic discontinuity during sevoflurane anesthesia in infants and children. Paediatr Anaesth. 2017 Mar;27(3):251-262. doi: 10.1111/pan.13061. Epub 2017 Feb 8.
- Cornelissen L, Kim SE, Purdon PL, Brown EN, Berde CB. Age-dependent electroencephalogram (EEG) patterns during sevoflurane general anesthesia in infants. Elife. 2015 Jun 23;4:e06513. doi: 10.7554/eLife.06513.
- Lerman J, Sikich N, Kleinman S, Yentis S. The pharmacology of sevoflurane in infants and children. Anesthesiology. 1994 Apr;80(4):814-24. doi: 10.1097/00000542-199404000-00014.
- Yuan I, Xu T, Skowno J, Zhang B, Davidson A, von Ungern-Sternberg BS, Sommerfield D, Zhang J, Song X, Zhang M, Zhao P, Liu H, Jiang Y, Zuo Y, de Graaff JC, Vutskits L, Olbrecht VA, Szmuk P, Kurth CD; BRAIN Collaborative Investigators. Isoelectric Electroencephalography in Infants and Toddlers during Anesthesia for Surgery: An International Observational Study. Anesthesiology. 2022 Aug 1;137(2):187-200. doi: 10.1097/ALN.0000000000004262.
- Yuan I, Landis WP, Topjian AA, Abend NS, Lang SS, Huh JW, Kirschen MP, Mensinger JL, Zhang B, Kurth CD. Prevalence of Isoelectric Electroencephalography Events in Infants and Young Children Undergoing General Anesthesia. Anesth Analg. 2020 Feb;130(2):462-471. doi: 10.1213/ANE.0000000000004221.
- Lee HC, Jung CW. Vital Recorder-a free research tool for automatic recording of high-resolution time-synchronised physiological data from multiple anaesthesia devices. Sci Rep. 2018 Jan 24;8(1):1527. doi: 10.1038/s41598-018-20062-4.
- Tokuwaka J, Satsumae T, Mizutani T, Yamada K, Inomata S, Tanaka M. The relationship between age and minimum alveolar concentration of sevoflurane for maintaining bispectral index below 50 in children. Anaesthesia. 2015 Mar;70(3):318-22. doi: 10.1111/anae.12890. Epub 2014 Oct 1.
- Katoh T, Kobayashi S, Suzuki A, Kato S, Iwamoto T, Bito H, Sato S. Fentanyl augments block of sympathetic responses to skin incision during sevoflurane anaesthesia in children. Br J Anaesth. 2000 Jan;84(1):63-6. doi: 10.1093/oxfordjournals.bja.a013384.
- Cornelissen L, Kim SE, Lee JM, Brown EN, Purdon PL, Berde CB. Electroencephalographic markers of brain development during sevoflurane anaesthesia in children up to 3 years old. Br J Anaesth. 2018 Jun;120(6):1274-1286. doi: 10.1016/j.bja.2018.01.037. Epub 2018 Apr 5.
- Bong CL, Long MHY. Sevoflurane requirements during electroencephalogram (EEG)-guided vs standard anesthesia care in children: A randomized controlled trial. J Clin Anesth. 2023 Jun;86:111071. doi: 10.1016/j.jclinane.2023.111071. Epub 2023 Feb 13. No abstract available.
- Pawar N, Barreto Chang OL. Burst Suppression During General Anesthesia and Postoperative Outcomes: Mini Review. Front Syst Neurosci. 2022 Jan 7;15:767489. doi: 10.3389/fnsys.2021.767489. eCollection 2021.
- Gao Z, Zhang J, Wang X, Yao M, Sun L, Ren Y, Qiu D. A retrospective study of electroencephalography burst suppression in children undergoing general anesthesia. Pediatr Investig. 2021 Aug 16;5(4):271-276. doi: 10.1002/ped4.12287. eCollection 2021 Dec.
- Chao JY, Gutierrez R, Legatt AD, Yozawitz EG, Lo Y, Adams DC, Delphin ES, Shinnar S, Purdon PL. Decreased Electroencephalographic Alpha Power During Anesthesia Induction Is Associated With EEG Discontinuity in Human Infants. Anesth Analg. 2022 Dec 1;135(6):1207-1216. doi: 10.1213/ANE.0000000000005864. Epub 2022 Nov 16.
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 2304-138-1427
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .