- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07479121
Deze studies beoordelen de fysieke en ergonomische werklast van chirurgen. Studie 1 vergelijkt laparoscopische versus Hugo RAS robotbenaderingen voor rectumresectie. Studie 2 vergelijkt Hugo RAS versus Da Vinci Xi voor prostatectomie. Beide volgen fysiologische stress, chirurgische belastingsfasen en uitgeoefende kracht. (ERGOROB)
Het ERGOROB-project (ERGOnomie in Chirurgische ROBotica)
The ERGOROB (ERGOnomics in surgical ROBotics) study is an observational research project focused on the physical well-being of surgeons.Why is this study important?Surgeons perform complex, lengthy procedures that can lead to severe physical strain, awkward postures, and repetitive movements.This physical burden often causes musculoskeletal disorders, which can negatively impact a doctor's health and potentially shorten their career.By objectively measuring these physical demands, researchers aim to improve the design of surgical systems and training protocols.Preserving a surgeon's health and expertise ultimately enhances the quality of care provided to patients.What exactly is being studied?The research is divided into two comparative areas:Study 1: Compares the physical strain on doctors performing bowel surgery (Low Anterior Resection of the Rectum) using standard "keyhole" (laparoscopic) methods versus a robotic-assisted system called the Hugo RAS.Study 2: Compares the physical demands of using two different robotic surgical platforms (the Hugo RAS and the Da Vinci Xi) during prostate surgery (Radical Prostatectomy).What does this mean for patients?In this specific study, the surgeons are the subjects being evaluated, not the patients.Patients receive their standard, planned surgical treatment without any alterations.During the operation, the participating surgeon will wear specialized wireless equipment, including a 3D motion capture suit, muscle activity sensors, and sensorized gloves to measure hand force.The procedure is also video recorded to analyze the surgeon's movements and workflow.All wearable equipment has been thoroughly pre-tested in a simulated environment to guarantee it does not interfere with the surgeon's dexterity or comfort while operating.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Contacten en locaties
Studiecontact
- Naam: Matteo Rottoli, MD, PhD
- Telefoonnummer: +390512144807
- E-mail: matteo.rottoli@unibo.it
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Must be an experienced general surgeon specializing in colorectal surgery (Study 1) OR an experienced urological surgeon (Study 2).
- Age between 40 and 55 years for colorectal surgeons, or between 40 and 50 years for urological surgeons.
- For Study 1: Proficient in performing Low Anterior Resection of the Rectum using both standard laparoscopic techniques and the Hugo RAS robotic system, with over 30 robotic and laparoscopic procedures completed.
- For Study 2: Expertise in robotic-assisted Radical Prostatectomy using both the Hugo RAS and Da Vinci Xi systems, with over 20 radical prostatectomies performed on both platforms.
- Willingness to undergo extensive data collection during surgical procedures.
- Provide written informed consent.
Exclusion Criteria:
- None.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Onderzoek naar gezondheidsdiensten
- Toewijzing: Niet-gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Colorectal Surgeons
5 experienced colorectal surgeons acting as their own controls. Each surgeon will perform 10 procedures: 5 using the standard laparoscopic approach and 5 using the Hugo RAS robotic system. |
This study evaluates the ergonomic impact of different surgical platforms on operating surgeons. The "interventions" are the surgical systems used during standard procedures:Study 1: Compares the standard laparoscopic approach (control) versus the Medtronic Hugo™ RAS robotic system during Low Anterior Resection of the Rectum.Study 2: Directly compares the Medtronic Hugo™ RAS system versus the Intuitive da Vinci® Xi System during Radical Prostatectomy.Distinguishing Feature: Unlike trials focused on patient outcomes, the surgeon is the subject of investigation here. During live surgeries, surgeons are continuously monitored using wearable assessment tools: Xsens 3D Motion Capture suits for posture and kinematics , WaveX wireless sEMG sensors for muscle activity and fatigue , and GRIP VERSATEK sensorized gloves (Study 2 only) for hand force. This enables real-time, objective ergonomic data collection. |
|
Experimenteel: Urological Surgeons
5 experienced urological surgeons acting as their own controls. Each surgeon will perform 10 procedures: 5 using the Hugo RAS robotic system and 5 using the Da Vinci Xi robotic system. |
This study evaluates the ergonomic impact of different surgical platforms on operating surgeons. The "interventions" are the surgical systems used during standard procedures:Study 1: Compares the standard laparoscopic approach (control) versus the Medtronic Hugo™ RAS robotic system during Low Anterior Resection of the Rectum.Study 2: Directly compares the Medtronic Hugo™ RAS system versus the Intuitive da Vinci® Xi System during Radical Prostatectomy.Distinguishing Feature: Unlike trials focused on patient outcomes, the surgeon is the subject of investigation here. During live surgeries, surgeons are continuously monitored using wearable assessment tools: Xsens 3D Motion Capture suits for posture and kinematics , WaveX wireless sEMG sensors for muscle activity and fatigue , and GRIP VERSATEK sensorized gloves (Study 2 only) for hand force. This enables real-time, objective ergonomic data collection. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Surgeon Muscle Activity (Root Mean Square)
Tijdsspanne: Intraoperatively
|
Assessment of surgeon muscle workload measured using WaveX wireless surface electromyography (sEMG) sensors placed on the trapezius, erector spinae, biceps brachii, and forearm extensor muscles. The parameter evaluated is the Root Mean Square (RMS) value for muscle activity. Measured continuously during each of the surgical procedures per participating surgeon. Unit of Measure: Microvolts (or specify your exact electrical potential unit) |
Intraoperatively
|
|
Surgeon Posture and Upper Limb Kinematics
Tijdsspanne: Continuously during each of the 10 surgical procedures per participating surgeon (real-time acquisition)
|
Evaluation of the surgeon's physical exertion and ergonomic posture deviations. Measured using the Xsens 3D Motion Capture Suit. Specific parameters include trunk flexion and lateral bending angles, shoulder and elbow range of motion (ROM), and the frequency and amplitude of repetitive movements of the upper limbs |
Continuously during each of the 10 surgical procedures per participating surgeon (real-time acquisition)
|
|
Surgeon Hand and Finger Manipulation Forces
Tijdsspanne: Continuously during each of the 10 surgical procedures per participating urological surgeon (real-time acquisition)
|
Assessment of the physical force exerted by the surgeon's hands when interacting with the robotic consoles (Hugo RAS vs. Da Vinci Xi). Measured using GRIP VERSATEK sensorized gloves. Parameters include peak forces, average forces, and force variability. |
Continuously during each of the 10 surgical procedures per participating urological surgeon (real-time acquisition)
|
|
Surgeon Muscle Fatigue (Median Frequency)
Tijdsspanne: Intraoperatively
|
Assessment of surgeon muscle fatigue via spectral analysis, measured using WaveX wireless surface electromyography (sEMG) sensors placed on the trapezius, erector spinae, biceps brachii, and forearm extensor muscles. The parameter evaluated is the median frequency of the sEMG signals. Measured continuously during each surgical procedures per participating surgeon. Unit of Measure: Hertz (Hz) |
Intraoperatively
|
|
Surgeon Muscle Strain (Sustained Activation)
Tijdsspanne: Intraoperatively
|
Assessment of surgeon muscle strain, measured using WaveX wireless surface electromyography (sEMG) sensors placed on the trapezius, erector spinae, biceps brachii, and forearm extensor muscles. The parameter evaluated is the duration of periods of sustained muscle activation and high levels of co-contraction. Measured continuously during each surgical procedures per participating surgeon. Unit of Measure: Seconds (or minutes) |
Intraoperatively
|
Medewerkers en onderzoekers
Publicaties en nuttige links
Algemene publicaties
- Burdorf A, Naaktgeboren B, de Groot HC. Occupational risk factors for low back pain among sedentary workers. J Occup Med. 1993 Dec;35(12):1213-20.
- Epstein S, Sparer EH, Tran BN, Ruan QZ, Dennerlein JT, Singhal D, Lee BT. Prevalence of Work-Related Musculoskeletal Disorders Among Surgeons and Interventionalists: A Systematic Review and Meta-analysis. JAMA Surg. 2018 Feb 21;153(2):e174947. doi: 10.1001/jamasurg.2017.4947. Epub 2018 Feb 21.
- Aghilinejad M, Ehsani AA, Talebi A, Koohpayehzadeh J, Dehghan N. Ergonomic risk factors and musculoskeletal symptoms in surgeons with three types of surgery: Open, laparoscopic, and microsurgery. Med J Islam Repub Iran. 2016 Dec 28;30:467. eCollection 2016.
Studie record data
Bestudeer belangrijke data
Studie start (Geschat)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Andere studie-ID-nummers
- ERGOROB
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .