Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Study of the Cell Response in the Tear Film After Overnight Contact Lens Wear (CORNWALL)

6 marca 2013 zaktualizowane przez: CIBA VISION

Polymorphonuclear Leukocyte Response During Overnight Lens Wear

The purpose of this study was to count and analyze the white blood cells in tear samples collected from study participants following sleep. The results from contact lens wearers were compared with the results from non-contact lens wearers.

Przegląd badań

Szczegółowy opis

The objective of the study was to determine and compare the relative oxidative response of polymorphonuclear neutrophils (PMNs), the relative cell adhesion response of PMNs, and the leukocyte population in tear samples collected from contact lens wearers and non-contact lens wearers. Tear samples were collected via a binocular eye-wash. The samples were processed, and a cell count was performed using a hemacytometer. Flow cytometry was used to determine the expression of different PMN cell markers before and after stimulation with bacterial lipopolysaccharide (LPS).

Typ studiów

Interwencyjne

Zapisy (Rzeczywisty)

65

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

    • Ontario
      • Waterloo, Ontario, Kanada, N2L 3G1
        • University of Waterloo Centre for Contact Lens Research

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

17 lat i starsze (Dziecko, Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Tak

Płeć kwalifikująca się do nauki

Wszystko

Opis

Inclusion Criteria:

  • 17 years of age or older.
  • Ocular examination in the last two years.
  • Has up-to-date spectacles.
  • Falls into one of the following three categories:

    • Adapted wearer of Lotrafilcon A contact lenses
    • Adapted wearer of Lotrafilcon B contact lenses
    • Does not wear contact lenses
  • Other protocol-defined inclusion criteria may apply.

Exclusion Criteria:

  • Ocular disease
  • Systemic or topical medications that may affect ocular health.
  • Known sensitivity to diagnostic pharmaceuticals used in study.
  • Uses artificial tears and/or rewetting drops.
  • Wears contact lenses on an overnight basis for more than one night per week.
  • Other protocol-defined exclusion criteria may apply.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Podstawowa nauka
  • Przydział: Nielosowe
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Pojedynczy

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Aktywny komparator: Lotrafilcon A
Lotrafilcon A contact lenses worn on a daily wear basis for 1 week, followed by 8 hours overnight wear in a replacement pair. After a 12-hour washout period, a new pair of lotrafilcon A contact lenses were dispensed for 4 weeks of daily wear, followed by 8 hours overnight wear.
Commercially marketed, silicone hydrogel, single-vision contact lens FDA-approved for daily and extended (overnight) wear for up to 30 nights.
Inne nazwy:
  • AIR OPTIX NIGHT & DAY AQUA
Hydrogen peroxide-based contact lens care system for nightly cleaning and disinfection of study lenses
Inne nazwy:
  • Clear Care®
Aktywny komparator: Lotrafilcon B
Lotrafilcon B contact lenses worn on a daily wear basis for 1 week, followed by 8 hours overnight wear in a replacement pair. After a 12-hour washout period, a new pair of lotrafilcon B contact lenses were dispensed for 4 weeks of daily wear, followed by 8 hours overnight wear.
Hydrogen peroxide-based contact lens care system for nightly cleaning and disinfection of study lenses
Inne nazwy:
  • Clear Care®
Commercially marketed, silicone hydrogel, single-vision contact lens FDA-approved for daily or extended (overnight) wear up to 6 nights.
Inne nazwy:
  • NIGHT & DAY®
Brak interwencji: No lens wear
No contact lens wear for the duration of the study. One 8-hour sleep at 1 week, followed by an 8-hour sleep 4 weeks later.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Leukocyte Population
Ramy czasowe: Week 5
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA). Different types of white blood cells (leukocytes) were identified, which included neutrophils, monocytes, and lymphocytes. The total amount of leukocytes for contact lens wearers and non-lens wearers is presented. Potential differences in leukocyte count between lens wearers and non-lens wearers may indicate a different immune response.
Week 5
Relative Cell Adhesion Response of Polymorphonuclear Leukocytes (PMNs)
Ramy czasowe: Week 5
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer. CD54 is a protein typically found in the cell membrane of leukocytes, which up-regulates during inflammation and promotes cell adhesion. Cell adhesion response is reported as a ratio of stimulated to non-stimulated samples.
Week 5
Relative Oxidative Response of Polymorphonuclear Leukocytes (PMNs)
Ramy czasowe: Week 5
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer. Oxidative response is reported as a ratio of activated to non-activated samples. DCF (dichlorofluorescein diacetate) is a molecular probe that measures the oxidative burst. Upon stimulation, the PMNs synthesize reactive oxygen species, such as superoxide or hydrogen peroxide, which is detected by the probe. Differences in the oxidative response between contact lens wearers and non-lens wearers is indicated by a shift in the ratio (stimulated/unstimulated).
Week 5
Change From Week 1 in Leukocyte Population at Week 5
Ramy czasowe: Week 1, Week 5
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA). Different types of white blood cells (leukocytes) were identified, which included neutrophils, monocytes, and lymphocytes. The difference between total leukocytes for contact lens wearers and non-lens wearers (Week 5 minus Week 1) is presented.
Week 1, Week 5
Change From 1 Week in Relative Cell Adhesion Response of PMNs at Week 5
Ramy czasowe: Week 1, Week 5
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer. Cell adhesion response is reported as a ratio of activated to non-activated samples. The difference between the ratio data for contact lens wearers and non-lens wearers (Week 5 minus Week 1) is presented.
Week 1, Week 5
Change From Week 1 in Relative Oxidative Response of PMNs at Week 5
Ramy czasowe: Week 1, Week 5
A tear sample was collected after 8 hours of sleep using an ocular surface cell collection apparatus (OSCCA) and analyzed on a flow cytometer. Oxidative response is reported as a ratio of activated to non-activated samples. The difference between the ratio data for contact lens wearers and non-lens wearers (Week 5 minus Week 1) is presented.
Week 1, Week 5

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Sponsor

Współpracownicy

Śledczy

  • Główny śledczy: Lyndon Jones, PhD FCOptom FAAO, Director, Centre for Contact Lens Research, School of Optometry, University of Waterloo

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów

1 maja 2011

Zakończenie podstawowe (Rzeczywisty)

1 stycznia 2012

Ukończenie studiów (Rzeczywisty)

1 stycznia 2012

Daty rejestracji na studia

Pierwszy przesłany

9 czerwca 2011

Pierwszy przesłany, który spełnia kryteria kontroli jakości

22 czerwca 2011

Pierwszy wysłany (Oszacować)

23 czerwca 2011

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Oszacować)

8 marca 2013

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

6 marca 2013

Ostatnia weryfikacja

1 marca 2013

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • P-373-C-102

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Badania kliniczne na Białe krwinki

Badania kliniczne na Lotrafilcon A contact lens

Subskrybuj