Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Opracowanie techniki obrazowania rezonansu magnetycznego całego ciała (MR) bez promieniowania w celu oceny stopnia zaawansowania dzieci z rakiem

28 września 2026 zaktualizowane przez: Stanford University

Opracowanie techniki obrazowania MR całego ciała bez promieniowania w celu oceny stopnia zaawansowania dzieci z rakiem.

A research study on the diagnosis of spread of disease for children who have been diagnosed with solid tumors using a new whole body imaging technique and a new MR contrast agent (ferumoxytol). Standard tests that are used to determine the extent and possible spread of a child's disease include magnetic resonance (MR) imaging, computed tomography (CT), Positron Emission Tomography (PET) as well as bone scanning, and metaiodobenzylguanidine (MIBG) scanning. The purpose of this study is to determine if newer imaging tests referred to as whole body diffusion-weighted MR and whole body PET/MR can detect the extent and spread of the disease as accurately or even better as the standard tests (CT, MR and/or PET/CT). The advantage of the new imaging test is that it is associated with no or significantly reduced radiation exposure compared to standard CT and PET/CT imaging tests. The results of whole body MR and PET/MR will be compared with that of the conventional, standard imaging studies for tumor detecting.

Przegląd badań

Szczegółowy opis

Primary Objective: To compare the sensitivity, specificity and accuracy of WB-DW-MR scans (new technique) with 18F- FDG PET or 18F- FDG PET/CT or 18F- FDG PET/MR scans.

Typ studiów

Interwencyjne

Zapisy (Rzeczywisty)

158

Faza

  • Faza 2
  • Faza 1

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

    • California
      • Stanford, California, Stany Zjednoczone, 94305
        • Stanford University Cancer Institute

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

6 lat do 40 lat (Dziecko, Dorosły)

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Wszystko

Opis

Inclusion Criteria:

  • Diagnosis of a solid extra-cranial tumor like malignant lymphoma or malignant sarcoma and
  • Scheduled for or completed a 18F-FDG-PET or 18F-FDG-PET/CT tumor staging procedure.
  • There will be no restrictions on prior treatment.
  • Very young children who need sedation or anesthesia will be excluded from the study.
  • In this pediatric & adult study, the participant or parent/guardian is consented, and the patient when a minor is given an assent form and involved in the discussion as appropriate.

Exclusion Criteria:

  • MR-incompatible metal implants,
  • need of sedation or claustrophobia.
  • Hemosiderosis/hemochromatosis (patients can still be included in 2nd branch without ferumoxytol)
  • There will be restrictions regarding use of other Investigational Agents: Pt with iron-overload will not receive Ferumoxytol
  • History of allergic reactions to similar compounds will be obtained and patients with a positive history of allergic reaction to iron compounds or other severe allergic reactions.will be excluded from the study.
  • Pregnant women and fetuses.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Diagnostyczny
  • Przydział: Nie dotyczy
  • Model interwencyjny: Zadanie dla jednej grupy
  • Maskowanie: Brak (otwarta etykieta)

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Eksperymentalny: WB-DW-MR scan

simultaneous WB-DW-MR scan and 18-F FDG PET scan

Inne nazwy:
  • Badanie PET z użyciem fludeoksyglukozy
Inne nazwy:
  • ferahem

WB-DW-MR scans will be obtained on a 3T PET-MR system

Inne nazwy:
  • Skan MR z dyfuzją całego ciała

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Area Under the Receiver Operating Characteristic Curve (ROC) of Maximum Standard Uptake Value (SUV)
Ramy czasowe: Baseline (day of scan), and 3 to 14 weeks post treatment (interval determined by tumor type and treatment protocol)

Clinical response prediction according to maximum Standard Uptake Value (SUV), assessed using receiver operating characteristic (ROC) curve analysis. Higher AUC values indicate better discrimination between responders and non-responders.

Baseline (day of scan), and 3 to 14 weeks post treatment (interval determined by tumor type and treatment protocol)
Area Under the Receiver Operating Characteristic Curve (ROC) of Minimum Apparent Diffusion Coefficient (ADC)
Ramy czasowe: Baseline (day of scan), and 3 to 14 weeks post treatment (interval determined by tumor type and treatment protocol)

Clinical response prediction according to minimum Apparent Diffusion Coefficient (ADC) values, assessed using receiver operating characteristic (ROC) curve analysis. The area under the ROC curve (AUC) measures the ability of minimum ADC values to distinguish responders from non-responders, with higher AUC values indicating better predictive performance.

Baseline (day of scan), and 3 to 14 weeks post treatment (interval determined by tumor type and treatment protocol)
Sensitivity and Specificity of WB-DW-MR Compared to 18F-FDG PET/CT
Ramy czasowe: 3 to 14 weeks post-treatment (interval determined by tumor type and treatment protocol)

Comparison of the sensitivity (true positive rate) and specificity (true negative rate) of WB-DW-MR scans versus standard 18F-FDG PET/CT scans for tumor detection and clinical response assessment, using imaging findings compared with the clinical reference standard (biopsy and/or follow-up imaging).

3 to 14 weeks post-treatment (interval determined by tumor type and treatment protocol)

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Signal-to-Noise Ratio as a Measure of Technical Optimization of Whole-Body Diffusion-Weighted MRI (WB-DW-MRI)
Ramy czasowe: Baseline (day of scan)

Signal-to-noise ratio (SNR) was assessed to evaluate and optimize pulse sequence parameters and b-values for whole-body diffusion-weighted MRI. SNR was calculated from signal intensity measurements obtained from bone marrow metastases and normal bone marrow regions on diffusion-weighted MRI images. b50 images provide higher signal-to-noise ratio and visualization of tissue perfusion/anatomy, while b800 images emphasize restricted diffusion associated with malignancy and suppress background tissue signal.

Baseline (day of scan)

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Śledczy

  • Główny śledczy: Heike Daldrup-Link, Stanford University

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

22 lutego 2012

Zakończenie podstawowe (Rzeczywisty)

8 sierpnia 2022

Ukończenie studiów (Rzeczywisty)

8 sierpnia 2022

Daty rejestracji na studia

Pierwszy przesłany

24 lutego 2012

Pierwszy przesłany, który spełnia kryteria kontroli jakości

1 marca 2012

Pierwszy wysłany (Szacowany)

2 marca 2012

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

6 października 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

28 września 2026

Ostatnia weryfikacja

1 września 2026

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • IRB-20221
  • NCI-2012-015321 (Inny identyfikator: National Cancer Institute: Clinical Trials Reporting Program)
  • 1R01CA269231-01A1 (Grant/umowa NIH USA)

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Tak

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj