The goal of this observational study is to utilize a novel imaging system designed for high-resolution retinal imaging of neonates, infants and children to identify the signs of photoreceptor development and degeneration in children with early-onset inherited retinal dystrophies (EORDs). Participants will have research imaging with SS-HH-OCT at the time of clinically-indicated eye examinations or procedures. The investigators aim to establish the basis for utilization of OCT imaging in earlier diagnosis and disease monitoring in children with EORDs. This work will set data reference standards and IRD endpoints that can be used in clinical trials.
Przegląd badań
Szczegółowy opis
What photoreceptor degenerative changes take place in children with early-onset inherited retinal dystrophies, and how is photoreceptor development in this patient population affected by genetic defects?
Our novel investigational SS-HH-OCT system features high scanning speed, long laser wavelength, and an ergonomic light-weight handheld design. The investigators hypothesize that imaging with this system will enable us to characterize early-onset retinal dystrophies (EORD)-associated PDCs in young children. To this end, the investigators propose the following specific aims:
Specific Aim 1: Optimize and demonstrate reproducibility of SS-HH-OCT imaging protocols to visualize photoreceptor development and degeneration in children with and without EORDs.
Specific Aim 2: Use SS-HH-OCT parameters to characterize biomarkers of foveal photoreceptor development and degeneration in children with EORDs versus healthy controls.
A total of 80 participants will be enrolled in this study. Participants' age between 0 through 8 years (<9 years).
For children with EORD, successful completion of this study will result in 1) a framework for reproducible OCT imaging; 2) characterization of biomarkers of retinal degeneration; 3) establishment of reference data by genetic variants 4) insights into foveal development. Additionally, this study will set pilot data of structure-function data and timeline of photoreceptor degeneration for future NIH funded studies.
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
North Carolina
-
Durham, North Carolina, Stany Zjednoczone, 27710
- Duke University Eye Center
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
For all participants:
- Participant's age is between 0 through 8 years (<9 years)
- Parent/legal guardian gives consents for the imaging study
- No ocular media opacities that could preclude imaging
- Refractive error equal or lower than 6 diopters
For EORD participants (Groups 1-2):
Meets clinical and molecular diagnosis of EORD (clinical determined by PI). Molecular diagnosis criteria:
- Autosomal dominant gene: One pathogenic or likely pathogenic variant that meets the clinical phenotype
- Autosomal recessive gene: two pathogenic or likely pathogenic variants in-trans which meet the phenotype.
- X-linked gene: one pathogenic or likely pathogenic variant which meets the phenotype.
For Controls (Group 3): No evidence of retinal pathology
Exclusion Criteria:
For all participants:
- Parent/legal guardian unwilling or unable to provide consent
- Refractive error higher than 6.00 diopters
- Participant has media opacities that preclude imaging
- Any non-IRD ocular condition that confound results interpretation such as glaucoma, uveitis, neurologic conditions affecting the optic nerve, etc.
For EORD participants (Groups 1-2): Does not meet molecular diagnosis criteria
For Controls (Group 3): Any suspicion of IRD
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Inny
- Przydział: Nielosowe
- Model interwencyjny: Przydział równoległy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Aktywny komparator: Group 1 - Progressive Inherited retinal dystrophy (IRD)
100 participants with progressive IRD; the most common IRD seen at Duke Clinics. |
The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.
Inne nazwy:
|
|
Aktywny komparator: Group 2 - Non-progressive Inherited Retinal Dystrophy (IRD)
20 participants with non-progressive IRD (n=20), a subset of IRDs that are less frequently referred to Duke Clinics |
The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.
Inne nazwy:
|
|
Aktywny komparator: Group 3 - Control participants
50 participants with normal retinal anatomy undergoing anesthesia for strabismus surgery as part of their clinically-indicated care. |
The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.
Inne nazwy:
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Number of participants with abnormal microanatomy as measured by OCT reading
Ramy czasowe: Up to 24 months
|
Presence of abnormal retinal microanatomy as measured by OCT reading |
Up to 24 months
|
|
Thickness of the participants retina at the fovea and surrounding optic nerve as measured by OCT reading
Ramy czasowe: Up to 24 months
|
Retinal thickness (microns) at the fovea and surrounding optic nerve |
Up to 24 months
|
Współpracownicy i badacze
Sponsor
Śledczy
- Główny śledczy: Ramiro Maldonado, MD, Duke University Eye Center
Publikacje i pomocne linki
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- Pro00113941
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
produkt wyprodukowany i wyeksportowany z USA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .