- ICH GCP
- USA klinikai vizsgálatok nyilvántartása
- Klinikai vizsgálat NCT06177977
Az SS-HH-OCT, mint a korai kezdetű retinális disztrófiák (EORD-ok) új diagnosztikai módszere (SS-HH-OCT)
Ultrakompakt kézi söpört forrású optikai koherencia tomográfia (SS-HH-OCT), mint új diagnosztikai módszer a korai kezdetű retinális disztrófiák (EORD) kezelésére
The goal of this observational study is to utilize a novel imaging system designed for high-resolution retinal imaging of neonates, infants and children to identify the signs of photoreceptor development and degeneration in children with early-onset inherited retinal dystrophies (EORDs). Participants will have research imaging with SS-HH-OCT at the time of clinically-indicated eye examinations or procedures. The investigators aim to establish the basis for utilization of OCT imaging in earlier diagnosis and disease monitoring in children with EORDs. This work will set data reference standards and IRD endpoints that can be used in clinical trials.
A tanulmány áttekintése
Részletes leírás
What photoreceptor degenerative changes take place in children with early-onset inherited retinal dystrophies, and how is photoreceptor development in this patient population affected by genetic defects?
Our novel investigational SS-HH-OCT system features high scanning speed, long laser wavelength, and an ergonomic light-weight handheld design. The investigators hypothesize that imaging with this system will enable us to characterize early-onset retinal dystrophies (EORD)-associated PDCs in young children. To this end, the investigators propose the following specific aims:
Specific Aim 1: Optimize and demonstrate reproducibility of SS-HH-OCT imaging protocols to visualize photoreceptor development and degeneration in children with and without EORDs.
Specific Aim 2: Use SS-HH-OCT parameters to characterize biomarkers of foveal photoreceptor development and degeneration in children with EORDs versus healthy controls.
A total of 80 participants will be enrolled in this study. Participants' age between 0 through 8 years (<9 years).
For children with EORD, successful completion of this study will result in 1) a framework for reproducible OCT imaging; 2) characterization of biomarkers of retinal degeneration; 3) establishment of reference data by genetic variants 4) insights into foveal development. Additionally, this study will set pilot data of structure-function data and timeline of photoreceptor degeneration for future NIH funded studies.
Tanulmány típusa
Beiratkozás (Tényleges)
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Tanulmányi helyek
-
-
North Carolina
-
Durham, North Carolina, Egyesült Államok, 27710
- Duke University Eye Center
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
Egészséges önkénteseket fogad
Tanulmányozható nemek
Leírás
Inclusion Criteria:
For all participants:
- Participant's age is between 0 through 8 years (<9 years)
- Parent/legal guardian gives consents for the imaging study
- No ocular media opacities that could preclude imaging
- Refractive error equal or lower than 6 diopters
For EORD participants (Groups 1-2):
Meets clinical and molecular diagnosis of EORD (clinical determined by PI). Molecular diagnosis criteria:
- Autosomal dominant gene: One pathogenic or likely pathogenic variant that meets the clinical phenotype
- Autosomal recessive gene: two pathogenic or likely pathogenic variants in-trans which meet the phenotype.
- X-linked gene: one pathogenic or likely pathogenic variant which meets the phenotype.
For Controls (Group 3): No evidence of retinal pathology
Exclusion Criteria:
For all participants:
- Parent/legal guardian unwilling or unable to provide consent
- Refractive error higher than 6.00 diopters
- Participant has media opacities that preclude imaging
- Any non-IRD ocular condition that confound results interpretation such as glaucoma, uveitis, neurologic conditions affecting the optic nerve, etc.
For EORD participants (Groups 1-2): Does not meet molecular diagnosis criteria
For Controls (Group 3): Any suspicion of IRD
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Egyéb
- Kiosztás: Nem véletlenszerű
- Beavatkozó modell: Párhuzamos hozzárendelés
- Maszkolás: Nincs (Open Label)
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
|---|---|
|
Aktív összehasonlító: Group 1 - Progressive Inherited retinal dystrophy (IRD)
100 participants with progressive IRD; the most common IRD seen at Duke Clinics. |
The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.
Más nevek:
|
|
Aktív összehasonlító: Group 2 - Non-progressive Inherited Retinal Dystrophy (IRD)
20 participants with non-progressive IRD (n=20), a subset of IRDs that are less frequently referred to Duke Clinics |
The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.
Más nevek:
|
|
Aktív összehasonlító: Group 3 - Control participants
50 participants with normal retinal anatomy undergoing anesthesia for strabismus surgery as part of their clinically-indicated care. |
The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.
Más nevek:
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
Number of participants with abnormal microanatomy as measured by OCT reading
Időkeret: Up to 24 months
|
Presence of abnormal retinal microanatomy as measured by OCT reading |
Up to 24 months
|
|
Thickness of the participants retina at the fovea and surrounding optic nerve as measured by OCT reading
Időkeret: Up to 24 months
|
Retinal thickness (microns) at the fovea and surrounding optic nerve |
Up to 24 months
|
Együttműködők és nyomozók
Szponzor
Nyomozók
- Kutatásvezető: Ramiro Maldonado, MD, Duke University Eye Center
Publikációk és hasznos linkek
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete (Tényleges)
Elsődleges befejezés (Tényleges)
A tanulmány befejezése (Tényleges)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Tényleges)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
Kulcsszavak
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- Pro00113941
Terv az egyéni résztvevői adatokhoz (IPD)
Tervezi megosztani az egyéni résztvevői adatokat (IPD)?
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
az Egyesült Államokban gyártott és onnan exportált termék
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .