SS-HH-OCT como uma nova modalidade de diagnóstico para distrofias retinianas de início precoce (EORDs) (SS-HH-OCT)
Tomografia de coerência óptica portátil ultracompacta de fonte varrida (SS-HH-OCT) como uma nova modalidade de diagnóstico para distrofias retinianas de início precoce (EORDs)
The goal of this observational study is to utilize a novel imaging system designed for high-resolution retinal imaging of neonates, infants and children to identify the signs of photoreceptor development and degeneration in children with early-onset inherited retinal dystrophies (EORDs). Participants will have research imaging with SS-HH-OCT at the time of clinically-indicated eye examinations or procedures. The investigators aim to establish the basis for utilization of OCT imaging in earlier diagnosis and disease monitoring in children with EORDs. This work will set data reference standards and IRD endpoints that can be used in clinical trials.
Visão geral do estudo
Descrição detalhada
What photoreceptor degenerative changes take place in children with early-onset inherited retinal dystrophies, and how is photoreceptor development in this patient population affected by genetic defects?
Our novel investigational SS-HH-OCT system features high scanning speed, long laser wavelength, and an ergonomic light-weight handheld design. The investigators hypothesize that imaging with this system will enable us to characterize early-onset retinal dystrophies (EORD)-associated PDCs in young children. To this end, the investigators propose the following specific aims:
Specific Aim 1: Optimize and demonstrate reproducibility of SS-HH-OCT imaging protocols to visualize photoreceptor development and degeneration in children with and without EORDs.
Specific Aim 2: Use SS-HH-OCT parameters to characterize biomarkers of foveal photoreceptor development and degeneration in children with EORDs versus healthy controls.
A total of 80 participants will be enrolled in this study. Participants' age between 0 through 8 years (<9 years).
For children with EORD, successful completion of this study will result in 1) a framework for reproducible OCT imaging; 2) characterization of biomarkers of retinal degeneration; 3) establishment of reference data by genetic variants 4) insights into foveal development. Additionally, this study will set pilot data of structure-function data and timeline of photoreceptor degeneration for future NIH funded studies.
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
North Carolina
-
Durham, North Carolina, Estados Unidos, 27710
- Duke University Eye Center
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
For all participants:
- Participant's age is between 0 through 8 years (<9 years)
- Parent/legal guardian gives consents for the imaging study
- No ocular media opacities that could preclude imaging
- Refractive error equal or lower than 6 diopters
For EORD participants (Groups 1-2):
Meets clinical and molecular diagnosis of EORD (clinical determined by PI). Molecular diagnosis criteria:
- Autosomal dominant gene: One pathogenic or likely pathogenic variant that meets the clinical phenotype
- Autosomal recessive gene: two pathogenic or likely pathogenic variants in-trans which meet the phenotype.
- X-linked gene: one pathogenic or likely pathogenic variant which meets the phenotype.
For Controls (Group 3): No evidence of retinal pathology
Exclusion Criteria:
For all participants:
- Parent/legal guardian unwilling or unable to provide consent
- Refractive error higher than 6.00 diopters
- Participant has media opacities that preclude imaging
- Any non-IRD ocular condition that confound results interpretation such as glaucoma, uveitis, neurologic conditions affecting the optic nerve, etc.
For EORD participants (Groups 1-2): Does not meet molecular diagnosis criteria
For Controls (Group 3): Any suspicion of IRD
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Outro
- Alocação: Não randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Comparador Ativo: Group 1 - Progressive Inherited retinal dystrophy (IRD)
100 participants with progressive IRD; the most common IRD seen at Duke Clinics. |
The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.
Outros nomes:
|
|
Comparador Ativo: Group 2 - Non-progressive Inherited Retinal Dystrophy (IRD)
20 participants with non-progressive IRD (n=20), a subset of IRDs that are less frequently referred to Duke Clinics |
The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.
Outros nomes:
|
|
Comparador Ativo: Group 3 - Control participants
50 participants with normal retinal anatomy undergoing anesthesia for strabismus surgery as part of their clinically-indicated care. |
The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.
Outros nomes:
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Number of participants with abnormal microanatomy as measured by OCT reading
Prazo: Up to 24 months
|
Presence of abnormal retinal microanatomy as measured by OCT reading |
Up to 24 months
|
|
Thickness of the participants retina at the fovea and surrounding optic nerve as measured by OCT reading
Prazo: Up to 24 months
|
Retinal thickness (microns) at the fovea and surrounding optic nerve |
Up to 24 months
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Ramiro Maldonado, MD, Duke University Eye Center
Publicações e links úteis
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- Pro00113941
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .