Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

SS-HH-OCT som en ny diagnostisk modalitet til retinale dystrofier (EORD'er) (SS-HH-OCT)

28. september 2026 opdateret af: Duke University

Ultrakompakt håndholdt optisk kohærenstomografi (SS-HH-OCT) som en ny diagnostisk modalitet for tidligt opstået retinal dystrofier (EORDs)

The goal of this observational study is to utilize a novel imaging system designed for high-resolution retinal imaging of neonates, infants and children to identify the signs of photoreceptor development and degeneration in children with early-onset inherited retinal dystrophies (EORDs). Participants will have research imaging with SS-HH-OCT at the time of clinically-indicated eye examinations or procedures. The investigators aim to establish the basis for utilization of OCT imaging in earlier diagnosis and disease monitoring in children with EORDs. This work will set data reference standards and IRD endpoints that can be used in clinical trials.

Studieoversigt

Status

Afsluttet

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

What photoreceptor degenerative changes take place in children with early-onset inherited retinal dystrophies, and how is photoreceptor development in this patient population affected by genetic defects?

Our novel investigational SS-HH-OCT system features high scanning speed, long laser wavelength, and an ergonomic light-weight handheld design. The investigators hypothesize that imaging with this system will enable us to characterize early-onset retinal dystrophies (EORD)-associated PDCs in young children. To this end, the investigators propose the following specific aims:

Specific Aim 1: Optimize and demonstrate reproducibility of SS-HH-OCT imaging protocols to visualize photoreceptor development and degeneration in children with and without EORDs.

Specific Aim 2: Use SS-HH-OCT parameters to characterize biomarkers of foveal photoreceptor development and degeneration in children with EORDs versus healthy controls.

A total of 80 participants will be enrolled in this study. Participants' age between 0 through 8 years (<9 years).

For children with EORD, successful completion of this study will result in 1) a framework for reproducible OCT imaging; 2) characterization of biomarkers of retinal degeneration; 3) establishment of reference data by genetic variants 4) insights into foveal development. Additionally, this study will set pilot data of structure-function data and timeline of photoreceptor degeneration for future NIH funded studies.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

137

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • North Carolina
      • Durham, North Carolina, Forenede Stater, 27710
        • Duke University Eye Center

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

1 sekund til 8 år (Barn)

Tager imod sunde frivillige

Ja

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

For all participants:

  • Participant's age is between 0 through 8 years (<9 years)
  • Parent/legal guardian gives consents for the imaging study
  • No ocular media opacities that could preclude imaging
  • Refractive error equal or lower than 6 diopters

For EORD participants (Groups 1-2):

Meets clinical and molecular diagnosis of EORD (clinical determined by PI). Molecular diagnosis criteria:

  • Autosomal dominant gene: One pathogenic or likely pathogenic variant that meets the clinical phenotype
  • Autosomal recessive gene: two pathogenic or likely pathogenic variants in-trans which meet the phenotype.
  • X-linked gene: one pathogenic or likely pathogenic variant which meets the phenotype.

For Controls (Group 3): No evidence of retinal pathology

Exclusion Criteria:

For all participants:

  • Parent/legal guardian unwilling or unable to provide consent
  • Refractive error higher than 6.00 diopters
  • Participant has media opacities that preclude imaging
  • Any non-IRD ocular condition that confound results interpretation such as glaucoma, uveitis, neurologic conditions affecting the optic nerve, etc.

For EORD participants (Groups 1-2): Does not meet molecular diagnosis criteria

For Controls (Group 3): Any suspicion of IRD

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Andet
  • Tildeling: Ikke-randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: Group 1 - Progressive Inherited retinal dystrophy (IRD)

100 participants with progressive IRD; the most common IRD seen at Duke Clinics.

The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.

Andre navne:
  • Swept-source håndholdt ultrakompakt optisk kohærenstomografi (HH UC OCT)
Aktiv komparator: Group 2 - Non-progressive Inherited Retinal Dystrophy (IRD)

20 participants with non-progressive IRD (n=20), a subset of IRDs that are less frequently referred to Duke Clinics

The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.

Andre navne:
  • Swept-source håndholdt ultrakompakt optisk kohærenstomografi (HH UC OCT)
Aktiv komparator: Group 3 - Control participants

50 participants with normal retinal anatomy undergoing anesthesia for strabismus surgery as part of their clinically-indicated care.

The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.

Andre navne:
  • Swept-source håndholdt ultrakompakt optisk kohærenstomografi (HH UC OCT)

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Number of participants with abnormal microanatomy as measured by OCT reading
Tidsramme: Up to 24 months

Presence of abnormal retinal microanatomy as measured by OCT reading

Up to 24 months
Thickness of the participants retina at the fovea and surrounding optic nerve as measured by OCT reading
Tidsramme: Up to 24 months

Retinal thickness (microns) at the fovea and surrounding optic nerve

Up to 24 months

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Efterforskere

  • Ledende efterforsker: Ramiro Maldonado, MD, Duke University Eye Center

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

1. marts 2024

Primær færdiggørelse (Faktiske)

5. februar 2026

Studieafslutning (Faktiske)

5. februar 2026

Datoer for studieregistrering

Først indsendt

11. december 2023

Først indsendt, der opfyldte QC-kriterier

11. december 2023

Først opslået (Faktiske)

20. december 2023

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

29. september 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

28. september 2026

Sidst verificeret

1. september 2026

Mere information

Begreber relateret til denne undersøgelse

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ja

produkt fremstillet i og eksporteret fra U.S.A.

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .