- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT06177977
SS-HH-OCT como nueva modalidad de diagnóstico para las distrofias de retina de aparición temprana (EORD) (SS-HH-OCT)
Tomografía de coherencia óptica de fuente de barrido portátil ultracompacta (SS-HH-OCT) como una nueva modalidad de diagnóstico para las distrofias retinianas de aparición temprana (EORD)
The goal of this observational study is to utilize a novel imaging system designed for high-resolution retinal imaging of neonates, infants and children to identify the signs of photoreceptor development and degeneration in children with early-onset inherited retinal dystrophies (EORDs). Participants will have research imaging with SS-HH-OCT at the time of clinically-indicated eye examinations or procedures. The investigators aim to establish the basis for utilization of OCT imaging in earlier diagnosis and disease monitoring in children with EORDs. This work will set data reference standards and IRD endpoints that can be used in clinical trials.
Descripción general del estudio
Descripción detallada
What photoreceptor degenerative changes take place in children with early-onset inherited retinal dystrophies, and how is photoreceptor development in this patient population affected by genetic defects?
Our novel investigational SS-HH-OCT system features high scanning speed, long laser wavelength, and an ergonomic light-weight handheld design. The investigators hypothesize that imaging with this system will enable us to characterize early-onset retinal dystrophies (EORD)-associated PDCs in young children. To this end, the investigators propose the following specific aims:
Specific Aim 1: Optimize and demonstrate reproducibility of SS-HH-OCT imaging protocols to visualize photoreceptor development and degeneration in children with and without EORDs.
Specific Aim 2: Use SS-HH-OCT parameters to characterize biomarkers of foveal photoreceptor development and degeneration in children with EORDs versus healthy controls.
A total of 80 participants will be enrolled in this study. Participants' age between 0 through 8 years (<9 years).
For children with EORD, successful completion of this study will result in 1) a framework for reproducible OCT imaging; 2) characterization of biomarkers of retinal degeneration; 3) establishment of reference data by genetic variants 4) insights into foveal development. Additionally, this study will set pilot data of structure-function data and timeline of photoreceptor degeneration for future NIH funded studies.
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
North Carolina
-
Durham, North Carolina, Estados Unidos, 27710
- Duke University Eye Center
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
For all participants:
- Participant's age is between 0 through 8 years (<9 years)
- Parent/legal guardian gives consents for the imaging study
- No ocular media opacities that could preclude imaging
- Refractive error equal or lower than 6 diopters
For EORD participants (Groups 1-2):
Meets clinical and molecular diagnosis of EORD (clinical determined by PI). Molecular diagnosis criteria:
- Autosomal dominant gene: One pathogenic or likely pathogenic variant that meets the clinical phenotype
- Autosomal recessive gene: two pathogenic or likely pathogenic variants in-trans which meet the phenotype.
- X-linked gene: one pathogenic or likely pathogenic variant which meets the phenotype.
For Controls (Group 3): No evidence of retinal pathology
Exclusion Criteria:
For all participants:
- Parent/legal guardian unwilling or unable to provide consent
- Refractive error higher than 6.00 diopters
- Participant has media opacities that preclude imaging
- Any non-IRD ocular condition that confound results interpretation such as glaucoma, uveitis, neurologic conditions affecting the optic nerve, etc.
For EORD participants (Groups 1-2): Does not meet molecular diagnosis criteria
For Controls (Group 3): Any suspicion of IRD
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Otro
- Asignación: No aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Comparador activo: Group 1 - Progressive Inherited retinal dystrophy (IRD)
100 participants with progressive IRD; the most common IRD seen at Duke Clinics. |
The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.
Otros nombres:
|
|
Comparador activo: Group 2 - Non-progressive Inherited Retinal Dystrophy (IRD)
20 participants with non-progressive IRD (n=20), a subset of IRDs that are less frequently referred to Duke Clinics |
The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.
Otros nombres:
|
|
Comparador activo: Group 3 - Control participants
50 participants with normal retinal anatomy undergoing anesthesia for strabismus surgery as part of their clinically-indicated care. |
The investigational swept source OCT systems with handheld UC handpieces used in this study were developed at Duke University. OCT systems are non-contact, in-vivo optical imaging technology. The OCT system creates real-time, non-invasive images of ocular microstructure. OCT devices held above or in front of the eye while the sweeping infrared OCT beam scans across the retina. In contrast to the visible light used in clinical eye examinations, because infrared light is not visible, the participant is not disturbed by the light. OCT imaging allows the capture of hundreds of B-scan (cross-sectional) images in seconds. These B-scans are then stacked to create a volume; the stack may be summed up to create a retinal image. These retinal images are similar to images acquired during retinal photography except that they were captured with infrared light and provide depth information. Each volume and B-scan image can be viewed individually to measure and analyze ocular pathology.
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Number of participants with abnormal microanatomy as measured by OCT reading
Periodo de tiempo: Up to 24 months
|
Presence of abnormal retinal microanatomy as measured by OCT reading |
Up to 24 months
|
|
Thickness of the participants retina at the fovea and surrounding optic nerve as measured by OCT reading
Periodo de tiempo: Up to 24 months
|
Retinal thickness (microns) at the fovea and surrounding optic nerve |
Up to 24 months
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Ramiro Maldonado, MD, Duke University Eye Center
Publicaciones y enlaces útiles
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- Pro00113941
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .