Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Comparação da oximetria de pulso (SpO2) com diferentes oxímetros e saturação arterial (SaO2): estudo Oxygap2 (Oxygap 2)

3 de novembro de 2026 atualizado por: François Lellouche, Laval University

The oximeter is used to monitor intensive care patients undergoing oxygen therapy. It indicates pulsed oxygen saturation (SpO2), a reflection of arterial oxygen saturation (SaO2) which enables detection of hypoxemia and hyperoxia, both deleterious state. Current SpO2 recommendations aim to reduce both risk of hypoxemia and hyperoxia. SpO2 is considered the 5th vital sign.

Current recommendations for SpO2 targets do not consider the variability of oximeters used in clinical practice. This variability and lack of specification represent an obstacle to an optimal practice of oxygen therapy.

Thus, this study aims to compare the SpO2 values of different oximeters (General Electric-GE, Medtronic, Masimo and Nonin) used in clinical practice with the SaO2 reference value obtained by an arterial gas in order to specify the precision and the systematic biases of the oximeters studied. This data will also make it possible to refine the recommendations concerning optimal oxygenation

Visão geral do estudo

Status

Recrutamento

Condições

Intervenção / Tratamento

Tipo de estudo

Observacional

Inscrição (Estimado)

250

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Quebec
      • Montreal, Quebec, Canadá, H3T 1C5
      • Montreal, Quebec, Canadá, H2X0A9
        • Concluído
        • CHUM
      • Québec, Quebec, Canadá, G1V 4G5
        • Recrutamento
        • Institut Universitaire de Cardiologie et de Pneumologie de Québec
        • Contato:
      • Les Abymes, Guadalupe, 97139
      • Sousse, Tunísia, 4000
        • Ainda não está recrutando
        • Hôpital Universitaire Farhat Hached,
        • Contato:

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

1 segundo a 100 anos (Filho, Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Método de amostragem

Amostra Não Probabilística

População do estudo

All patient in ICU with arterial catheter already installed will be consider

Descrição

Adult population

Inclusion Criteria:

  • ≥ 18 years old (adult population) -
  • Patients admitted to the Intensive Care Unit
  • Artery catheter already installed

Pediatric population

  • Below 18 years old
  • Patients admitted to the Intensive Care Unit
  • Artery catheter already installed

Exclusion Criteria:

  • No or poor signal with the usual pulse oximeter/based on clinician judgment
  • High dose of vasopressors or inotropes (epinephrine or norepinephrine ˃ 1mcg/kg/min), shock state (lactates above 3 mmoles/L)
  • Pigmented nails or nail polish
  • Methemoglobinemia history
  • Hemoglobin below 80 g/L
  • Patient in isolation (multi-resistant bacteria, C-Difficile, SARS-COV-2…)
  • Prone position, Extra Corporel Membrane Oxygenator

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Modelos de observação: COHORT
  • Perspectivas de Tempo: PROSPECTIVE

Coortes e Intervenções

Grupo / Coorte
Intervenção / Tratamento
Pediatric population

Pediatric population < 18 years old (estimated 100 patients)

Several pulse oximeter will be place on patient find few minutes before arterial blood gases. During an arterial blood sample, all SpO2 will be recorded

Adult population

Adult population >or= 18 years old (estimated 150 patients)

Several pulse oximeter will be place on patient find few minutes before arterial blood gases. During an arterial blood sample, all SpO2 will be recorded

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Difference between GE oximeter SpO2 value and the SaO2 value on arterial blood gases
Prazo: During procedure (arterial blood gas sample collection)

Difference between GE oximeter SpO2 and the SaO2 value

During procedure (arterial blood gas sample collection)
Difference between Nellcor oximeter SpO2 value and the SaO2 value on arterial blood gases
Prazo: During procedure (arterial blood gassample collection)

Difference between Nellcor oximeter SpO2 and the SaO2 value

During procedure (arterial blood gassample collection)
Difference between Masimo oximeter SpO2 value and the SaO2 value on arterial blood gases
Prazo: During procedure (arterial blood gas sample collection)

Difference between Masimo oximeter SpO2 and the SaO2 value

During procedure (arterial blood gas sample collection)
Difference between Nonin oximeter SpO2 value and the SaO2 value on arterial blood gases
Prazo: During procedure (arterial blood gas sample collection)

Difference between Nonin oximeter SpO2 and the SaO2 value

During procedure (arterial blood gas sample collection)

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Overestimation and underestimation of SaO2
Prazo: During procedure (arterial blood gas sample collection)

Percent of pairs with overestimation and underestimation of SaO2 for each oximeter.

During procedure (arterial blood gas sample collection)
Hypoxemia detection
Prazo: During procedure (arterial blood gas sample collection)

Ability to detect hypoxemia (SpO2 below 90% and PaO2 < 60 mmHg)

During procedure (arterial blood gas sample collection)

Outras medidas de resultado

Medida de resultado
Descrição da medida
Prazo
Hyperoxemia detection
Prazo: During procedure (arterial blood gas sample collection)

Ability to detect hyperoxemia (SpO2 above 95% and PaO2 > 100 mmHg)

During procedure (arterial blood gas sample collection)
Gaps between the different oximeters
Prazo: During procedure (arterial blood gas sample collection)

Average of the SpO2 value gaps between the different oximeters tested

During procedure (arterial blood gas sample collection)

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

20 de junho de 2024

Conclusão Primária (Estimado)

30 de junho de 2027

Conclusão do estudo (Estimado)

30 de dezembro de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

6 de outubro de 2023

Enviado pela primeira vez que atendeu aos critérios de CQ

25 de outubro de 2023

Primeira postagem (Real)

26 de outubro de 2023

Atualizações de registro de estudo

Última Atualização Postada (Real)

5 de novembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

3 de novembro de 2026

Última verificação

1 de novembro de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • 22373

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .