- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT06136169
Обучение сканированию напоминаний при одноименной потере поля зрения
Обучение сканированию напоминаний для людей с одноименной потерей поля зрения
This study will evaluate a new approach to training people with visual field loss to scan when driving
Обзор исследования
Статус
Вмешательство/лечение
Подробное описание
Homonymous visual field loss is the loss of vision on the same side in both eyes. The most common types are hemianopia (the loss of one half of the field of vision) and quadrantanopia (the loss of one quarter of the field of vision). Hemianopia and quadrantanopia may cause difficulties in seeing objects on the side of the field loss. People with these types of field loss can compensate by scanning (looking) toward the side of the field loss. However, sometimes they might not scan sufficiently well resulting in delayed responses to hazards when driving. The purpose of this research study is to evaluate a new approach, "reminder-cue scanning training", to training people with homonymous visual field loss to scan when driving.
Participants will receive reminder-cue scanning training in the driving simulator.Typically there will be three training sessions within about a 2-week period. In addition, participants will complete an evaluation in the driving simulator before and after the training.
Тип исследования
Регистрация (Действительный)
Фаза
- Непригодный
Контакты и местонахождение
Места учебы
-
-
Massachusetts
-
Boston, Massachusetts, Соединенные Штаты, 02114
- Schepens Eye Research Institute of Mass Eye and Ear
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- Homonymous hemianopia or homonymous quadrantanopia for at least 3 months
- Binocular visual acuity of at least 20/40
- Prior or current driving experience
- Able to attend multiple study visits
- Able to communicate in English sufficiently to understand the study procedures
Exclusion Criteria:
- Physical or general health problems that could impair the ability to operate the controls of the driving simulator or participate in the training
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Другой
- Распределение: Н/Д
- Интервенционная модель: Одногрупповое задание
- Маскировка: Нет (открытая этикетка)
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Экспериментальный: StudyArm
Participants will receive reminder-cue scanning training in a driving simulator. |
Auditory reminders to scan when scanning to the side of the field loss is inadequate |
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Rate of Early Large Head Scans to the Side of the Field Loss
Временное ограничение: Pre-training, post-training (1 week)
|
Percentage of intersections at which an early large head scan was made to the side of the field loss |
Pre-training, post-training (1 week)
|
|
Detection Rate for Hazards on the Side of the Field Loss
Временное ограничение: Pre-training, Post-training (1 week)
|
Percentage of hazards detected out of the total number of hazards on the side of the field loss |
Pre-training, Post-training (1 week)
|
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Number of Head Scans to the Side of the Field Loss
Временное ограничение: Pre-training, Post-training (1 week)
|
Number of head scans per intersection to the side of the field loss. A validated algorithm was used to detect head scans, defined as lateral rotations of the head away from the straight ahead position toward either the left or the right, which exceeded a predefined threshold based on the participant's distance to the intersection: ≥ 4° (100 to 50 m to intersection), ≥ 6° (50 to 20m), ≥ 10° (20 to 0m). Savage SW, Zhang L, Swan G, Bowers AR (2020) The effects of age on the contributions of head and eye movements to scanning behavior at intersections. Transp Res Part F Traffic Psychol Behav. 73:128-142. Swan G, Goldstein RB, Savage SW, Zhang L, Ahmadi A, Bowers AR (2021) Automatic processing of gaze movements to quantify gaze scanning behaviors in a driving simulator. Behav Res Methods. 53(2): 487-506 |
Pre-training, Post-training (1 week)
|
|
Magnitude of Head Scans to the Side of the Field Loss
Временное ограничение: Pre-training, Post-training (1 week)
|
Mean magnitude (in degrees) of head scans to the side of the field loss. A validated algorithm was used to detect head scans, defined as lateral rotations of the head away from the straight ahead position toward either the left or the right, which exceeded a predefined threshold based on the participant's distance to the intersection: ≥ 4° (100 to 50 m to intersection), ≥ 6° (50 to 20m), ≥ 10° (20 to 0m). The magnitude is the lateral angular extent of the scan measured from the straight-ahead position to the furthest lateral position to the left or right. Savage SW, Zhang L, Swan G, Bowers AR (2020) The effects of age on the contributions of head and eye movements to scanning behavior at intersections. Transp Res Part F Traffic Psychol Behav. 73:128-142. Swan G, Goldstein RB, Savage SW, Zhang L, Ahmadi A, Bowers AR (2021) Automatic processing of gaze movements to quantify gaze scanning behaviors in a driving simulator. Behav Res Methods. 53(2): 487-506 |
Pre-training, Post-training (1 week)
|
|
Response Times to Hazards on the Side of the Field Loss
Временное ограничение: Pre-training, Post-training (1 week)
|
Mean time (in seconds) between the hazard appearing and the horn-press response |
Pre-training, Post-training (1 week)
|
Соавторы и исследователи
Соавторы
Следователи
- Главный следователь: Alex Bowers, PhD, Schepens Eye Research Institute of Mass Eye and Ear
Публикации и полезные ссылки
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- 2023P003033
- R01EY025677 (Грант/контракт NIH США)
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .