Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

Повышение эффективности и картирование неинвазивных методов стимуляции головного мозга (BoMAP NIBS)

17 сентября 2026 г. обновлено: Friedhelm Hummel, Ecole Polytechnique Fédérale de Lausanne

Усиление и картирование пластичности, индуцированной неинвазивной стимуляцией мозга у людей

In this study we applied TMS to the hand area of M1 whilst acquiring fMRI of the brain. This study tested whether a higher-frequency form of brain stimulation, called high-gamma (100Hz) intermittent theta burst stimulation (iTBS), more effectively increases brain excitability than the standard 50Hz iTBS. In a double-blind, randomized study with 22 healthy participants, brain activity and motor responses were measured using TMS-fMRI. The 100Hz iTBS condition produced stronger and more consistent increases in motor excitability and greater activation of sensorimotor brain regions compared to 50Hz and sham stimulation, suggesting it may be a more effective approach for non-invasive neuromodulation.

Обзор исследования

Подробное описание

This study investigates whether a modified form of brain stimulation called high-gamma intermittent theta burst stimulation (iTBS) can more effectively and consistently increase brain excitability compared to the standard iTBS protocol. iTBS is a non-invasive method that uses magnetic pulses to influence brain activity, but responses vary widely between people.

In this double-blind, randomized, within-subject study, 22 healthy adults completed three sessions of brain stimulation combined with functional MRI (TMS-fMRI). Each participant received conventional 50Hz iTBS, high-gamma 100Hz iTBS, and a sham (placebo) condition on separate visits. Changes in motor cortex excitability were measured using motor-evoked potentials (MEPs), and brain activity and connectivity were assessed using fMRI.

The results showed that 100Hz iTBS produced stronger and more reliable increases in cortical excitability compared to both the 50Hz and sham conditions. High-gamma iTBS also activated broader areas of the sensorimotor network and showed stronger links between stimulation strength and neural response. These findings suggest that high-gamma iTBS may be a more effective and physiologically relevant approach for non-invasive brain stimulation in humans.

Тип исследования

Интервенционный

Регистрация (Действительный)

22

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

    • Canton of Geneva
      • Geneva, Canton of Geneva, Швейцария, 1202
        • Campus Biotech

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

От 18 лет до 35 лет (Взрослый)

Принимает здоровых добровольцев

Да

Полы, имеющие право на обучение

Все

Описание

Inclusion Criteria:

  • Right handed

Exclusion Criteria:

  • Contraindications to either TMS or MRI:

Pregnant Metal implants Use of recreational drugs Neurological conditions History of seizures or epilepsy

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Фундаментальная наука
  • Распределение: Рандомизированный
  • Интервенционная модель: Назначение кроссовера
  • Маскировка: Двойной

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Экспериментальный: 100Hz iTBS (intermittent theta burst protocol of rTMS)

The high-frequency of the stimulation is what distinguishes it from the other stimulation types and it is the goal of the study to see if this stimulation protocol is more effective than the classical protocol

iTBS applies a train of 3 pulses of stimulation, delivered at a gamma frequency, then repeated 10x at a theta repetition rate. Intensity of stimulation is personalized based on the individual's resting motor threshold, determined at the start of the session and delivered at 70% of this.

Другие имена:
  • рТМС
  • iTBS
Активный компаратор: 50Hz iTBS (intermittent theta burst protocol of rTMS)

The classical low-frequency protocol of stimulation, this one is being used to compare to the novel high-frequency protocol

iTBS applies a train of 3 pulses of stimulation, delivered at a gamma frequency, then repeated 10x at a theta repetition rate. Intensity of stimulation is personalized based on the individual's resting motor threshold, determined at the start of the session and delivered at 70% of this.

Другие имена:
  • рТМС
  • iTBS
Фальшивый компаратор: Sham iTBS (intermittent theta burst protocol of rTMS)

The sham stimulation was delivered with a 50Hz iTBS protocol except that the stimulation intensity was halved so as to retain the sensation of stimulation whilst not activating neurons

iTBS applies a train of 3 pulses of stimulation, delivered at a gamma frequency, then repeated 10x at a theta repetition rate. Intensity of stimulation is personalized based on the individual's resting motor threshold, determined at the start of the session and delivered at 70% of this.

Другие имена:
  • рТМС
  • iTBS

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Functional magnetic resonance imaging (fMRI)
Временное ограничение: Throughout the whole experiment, for a total of 26 minutes

fMRI of the brain and spinal chord were acquired during stimulation with single pulse TMS to elucidate the changes in BOLD activity occurring from the intervention.

Throughout the whole experiment, for a total of 26 minutes
Motor evoked potentials (MEPs)
Временное ограничение: MEPs are measured for 8mins immediately before intervention, then 15 minutes after intervention for a further 8 minutes.

When single pulses of TMS are applied to M1 hand region, MEPs are evoked in the corresponding hand muscle which can be measured with electromyography (EMG). The amplitude of the MEPs before and after the iTBS interventions are then measured and compared to determine the response to the iTBS, whether this is facilitation, suppression, or no change.

MEPs are measured for 8mins immediately before intervention, then 15 minutes after intervention for a further 8 minutes.

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

2 февраля 2023 г.

Первичное завершение (Действительный)

12 апреля 2024 г.

Завершение исследования (Действительный)

12 апреля 2024 г.

Даты регистрации исследования

Первый отправленный

19 февраля 2026 г.

Впервые представлено, что соответствует критериям контроля качества

19 февраля 2026 г.

Первый опубликованный (Действительный)

24 февраля 2026 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

22 сентября 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

17 сентября 2026 г.

Последняя проверка

1 сентября 2026 г.

Дополнительная информация

Термины, связанные с этим исследованием

Другие идентификационные номера исследования

  • 2021-01887

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕТ

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

продукт, произведенный в США и экспортированный из США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться