Miglioramento e Mappatura delle Tecniche di Stimolazione Cerebrale Non Invasiva (BoMAP NIBS)

17 settembre 2026 aggiornato da: Friedhelm Hummel, Ecole Polytechnique Fédérale de Lausanne

Potenziamento e mappatura della plasticità indotta dalla stimolazione cerebrale non invasiva nell'uomo

In this study we applied TMS to the hand area of M1 whilst acquiring fMRI of the brain. This study tested whether a higher-frequency form of brain stimulation, called high-gamma (100Hz) intermittent theta burst stimulation (iTBS), more effectively increases brain excitability than the standard 50Hz iTBS. In a double-blind, randomized study with 22 healthy participants, brain activity and motor responses were measured using TMS-fMRI. The 100Hz iTBS condition produced stronger and more consistent increases in motor excitability and greater activation of sensorimotor brain regions compared to 50Hz and sham stimulation, suggesting it may be a more effective approach for non-invasive neuromodulation.

Panoramica dello studio

Descrizione dettagliata

This study investigates whether a modified form of brain stimulation called high-gamma intermittent theta burst stimulation (iTBS) can more effectively and consistently increase brain excitability compared to the standard iTBS protocol. iTBS is a non-invasive method that uses magnetic pulses to influence brain activity, but responses vary widely between people.

In this double-blind, randomized, within-subject study, 22 healthy adults completed three sessions of brain stimulation combined with functional MRI (TMS-fMRI). Each participant received conventional 50Hz iTBS, high-gamma 100Hz iTBS, and a sham (placebo) condition on separate visits. Changes in motor cortex excitability were measured using motor-evoked potentials (MEPs), and brain activity and connectivity were assessed using fMRI.

The results showed that 100Hz iTBS produced stronger and more reliable increases in cortical excitability compared to both the 50Hz and sham conditions. High-gamma iTBS also activated broader areas of the sensorimotor network and showed stronger links between stimulation strength and neural response. These findings suggest that high-gamma iTBS may be a more effective and physiologically relevant approach for non-invasive brain stimulation in humans.

Tipo di studio

Interventistico

Iscrizione (Effettivo)

22

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Canton of Geneva
      • Geneva, Canton of Geneva, Svizzera, 1202
        • Campus Biotech

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 35 anni (Adulto)

Accetta volontari sani

Sì

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Right handed

Exclusion Criteria:

  • Contraindications to either TMS or MRI:

Pregnant Metal implants Use of recreational drugs Neurological conditions History of seizures or epilepsy

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Scienza basilare
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione incrociata
  • Mascheramento: Doppio

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: 100Hz iTBS (intermittent theta burst protocol of rTMS)

The high-frequency of the stimulation is what distinguishes it from the other stimulation types and it is the goal of the study to see if this stimulation protocol is more effective than the classical protocol

iTBS applies a train of 3 pulses of stimulation, delivered at a gamma frequency, then repeated 10x at a theta repetition rate. Intensity of stimulation is personalized based on the individual's resting motor threshold, determined at the start of the session and delivered at 70% of this.

Altri nomi:
  • rTMS
  • iTBS
Comparatore attivo: 50Hz iTBS (intermittent theta burst protocol of rTMS)

The classical low-frequency protocol of stimulation, this one is being used to compare to the novel high-frequency protocol

iTBS applies a train of 3 pulses of stimulation, delivered at a gamma frequency, then repeated 10x at a theta repetition rate. Intensity of stimulation is personalized based on the individual's resting motor threshold, determined at the start of the session and delivered at 70% of this.

Altri nomi:
  • rTMS
  • iTBS
Comparatore fittizio: Sham iTBS (intermittent theta burst protocol of rTMS)

The sham stimulation was delivered with a 50Hz iTBS protocol except that the stimulation intensity was halved so as to retain the sensation of stimulation whilst not activating neurons

iTBS applies a train of 3 pulses of stimulation, delivered at a gamma frequency, then repeated 10x at a theta repetition rate. Intensity of stimulation is personalized based on the individual's resting motor threshold, determined at the start of the session and delivered at 70% of this.

Altri nomi:
  • rTMS
  • iTBS

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Functional magnetic resonance imaging (fMRI)
Lasso di tempo: Throughout the whole experiment, for a total of 26 minutes

fMRI of the brain and spinal chord were acquired during stimulation with single pulse TMS to elucidate the changes in BOLD activity occurring from the intervention.

Throughout the whole experiment, for a total of 26 minutes
Motor evoked potentials (MEPs)
Lasso di tempo: MEPs are measured for 8mins immediately before intervention, then 15 minutes after intervention for a further 8 minutes.

When single pulses of TMS are applied to M1 hand region, MEPs are evoked in the corresponding hand muscle which can be measured with electromyography (EMG). The amplitude of the MEPs before and after the iTBS interventions are then measured and compared to determine the response to the iTBS, whether this is facilitation, suppression, or no change.

MEPs are measured for 8mins immediately before intervention, then 15 minutes after intervention for a further 8 minutes.

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

2 febbraio 2023

Completamento primario (Effettivo)

12 aprile 2024

Completamento dello studio (Effettivo)

12 aprile 2024

Date di iscrizione allo studio

Primo inviato

19 febbraio 2026

Primo inviato che soddisfa i criteri di controllo qualità

19 febbraio 2026

Primo Inserito (Effettivo)

24 febbraio 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

22 settembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

17 settembre 2026

Ultimo verificato

1 settembre 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • 2021-01887

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

prodotto fabbricato ed esportato dagli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi