Efficacy of Self-Expanding Nitinol S.M.A.R.T CONTROL Stent Versus Life Stent For The Atherosclerotic Femoro-Popliteal Arterial Disease (SENS-FP-2)
Efficacy of Self-Expanding Nitinol S.M.A.R.T CONTROLTM Stent Versus Life Stent For The Atherosclerotic Femoro-Popliteal Arterial Disease : Prospective, Multicenter, Randomized, Controlled Trial (SENS-FP-2 Trial)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Contact
Study Contact
- Name: Seung-Woon Rha, MD, PhD
- Phone Number: 82-2-818-6387
- Email: swrha617@yahoo.co.kr
Study Contact Backup
- Name: Sang-Ho Park, MD
- Phone Number: 82-41-570-3670
- Email: matsalong@schmc.ac.kr
Study Locations
-
-
-
Seoul, Korea, Republic of
- Korea University Guro Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
Clinical criteria
- Age 20 years of older
- Symptomatic peripheral-artery disease with (Rutherford 2 - 6); moderate to severe claudication (Rutherford 2-3), chronic critical limb ischemia with pain while was at rest (Rutherford 4), or with ischemic ulcers (Rutherford 5-6)
- Patients with signed informed consent
Anatomical criteria
- Target lesion length < 3 cm by angiographic estimation
- Stenosis of >50% or occlusive atherosclerotic lesion of the ipsilateral femoropopliteal artery
- Patent (≤50% stenosis) ipsilateral iliac artery or concomitantly treatable ipsilateral iliac lesions (≤30% residual stenosis),
- At least one patent (less than 50% stenosed) tibioperoneal run-off vessel.
Exclusion Criteria:
- Disagree with written informed consent
- Major bleeding history within prior 2 months
- Known hypersensitivy or contraindication to any of the following medication: heparin, aspirin, clopidogrel or contrast agent
- Acute limb ischemia
- Previous bypass surgery or stenting of the ipsilateral femoropopliteal artery
- Untreated inflow disease of the ipsilateral pelvic arteries (more than 50% stenosis or occlusion)
- Patients that major amputation ("above the ankle" amputation) has been done, is planned or required
- Patients with life expectancy <1 year due to comorbidity
- end-staged renal failure on hemodialysis or peritoneal dialysis
- Age > 85 years
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: LifeStent
same to SMART CONTROL Stent
|
same to SMART STENT
|
|
Active Comparator: SMART CONTROL Stent
study design is 2x2 randomization design.
First, before randomization, stratification will be performed according to lesion length 15cm criteria at web-based computerized program.
Patients will be randomized in a 1:1 manner according to different two (SMART versus LifeStent) stents.
And then, patients received aspirin and clopidogrel during one month.
After one month from index procedure, clopidogrel will be stopped and changed into cilostazol.
Patients were randomized to receive cilostazol 100mg bid either 11 month duration or 5 month duration in separate groups of SMART stent group and LifeStent group.
Randomization procedure will be performed using a web-based program
|
Provisional stenting should be performed; the case that optimal ballooning response is not obtained (sub-optimal balloon response) should be enrolled.
The procedure is usually done, as follows; After the guidewire is passed through the target lesion, predilation of the target lesion with an optimally sized balloon will be performed prior to stent implantation.
Recommended, minimal balloon dilation time is 120 seconds.
The sub-optimal balloon response is defined as a residual pressure gradient of >15 mmHg, residual stenosis of >30%, and flow-limiting dissection.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The rate of binary restenosis
Time Frame: one year
|
binary restenosis is defined as the restenosis of at least 50 percent of the luminal diameter in the treated segment at 12 months after intervention, when determined by catheter angiography.
|
one year
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
stent fracture rate, clinical outcomes, angiographic outcomes, ankle-brachial index
Time Frame: 1 year
|
|
1 year
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- SENS-FP-2-LifeStent Arm
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.