Loss of Resistance, w/wo Stimulation, For Epidural Placement
Loss of Resistance With Nerve Stimulation Versus Loss of Resistance Alone; Effect on Success of Thoracic Epidural Placement.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
North Carolina
-
Winston-Salem, North Carolina, United States, 27157
- WakeForestUBMC
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Adults undergoing intra-thoracic or intra-abdominal procedures that normally would receive thoracic epidurals for post-operative analgesia will be eligible.
Exclusion Criteria:
- Subjects with contraindications to regional anesthesia:
- history of allergy to amide local anesthetics
- presence of a progressive neurological deficit
- patients that are on anticoagulant medications that prohibit placement of an epidural
- Systemic infection
- Infection at the site of placement
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Supportive Care
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Traditional Technique Group
In the traditional loss of resistance technique group, the epidural catheter will be placed after achieving loss of resistance to air.
After placement of the catheter a standard test dose of 3+2 ml of 1.5% lidocaine with 1:200,000 epinephrine will be administered.Solution for Thoracic epidural block.
|
Thoracic epidural block with epidural placed with a loss of resistance technique alone.
Dose of 3+2 ml of 1.5% lidocaine with 1:200,000 epinephrine
Other Names:
|
|
Experimental: Electric Stimulation Group
In the electrical stimulation group, following the location of the epidural space with a loss of resistance technique (using air), nerve stimulation will be utilized to elicit a myotomal contraction of the abdominal or thoracic wall.
After placement of the catheter a standard test dose of 3+2 ml of 1.5% lidocaine with 1:200,000 epinephrine will be administered.Solution for Thoracic epidural block.Thoracic epidural block with Electrical Nerve stimulation
|
Thoracic epidural block with epidural placed with a loss of resistance technique alone.
Dose of 3+2 ml of 1.5% lidocaine with 1:200,000 epinephrine
Other Names:
In the electrical stimulation group, following the location of the epidural space with a loss of resistance technique (using air), nerve stimulation will be utilized to elicit a myotomal contraction of the abdominal or thoracic wall.stimulating
peripheral nerve catheters(19 Ga.
x 90 cm StimuCath® Continuous Nerve Block Catheter with SnapLock™ Adapter (Arrow by Teleflex Medical, Morrisville, NC), and stimulation will be achieved using a B Braun Stimuplex HNS12 Nerve Stimulator product id 4892098.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Success Rate of Placement of a Thoracic Epidural
Time Frame: 15 minutes after administration of a test dose of lidocaine
|
will be determined by the detection of a loss of sensation to cold (ice) in at least two contiguous dermatomal levels, 15 minutes after administration of a test dose of lidocaine through the epidural catheter.
If a loss of cold sensation is found, then the epidural placement will be classified as successful.
If no loss of cold sensation is found, then the epidural placement will be classified as unsuccessful.
|
15 minutes after administration of a test dose of lidocaine
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Time Required to Place the Epidural Catheter
Time Frame: From the initiation of procedure to end of procedure
|
The time required to place the epidural catheter will be recorded
|
From the initiation of procedure to end of procedure
|
|
Number of Thoracic Spine Levels Attempted
Time Frame: Thirty minutes after start of procedure.
|
the number of thoracic spine levels attempted will be recorded
|
Thirty minutes after start of procedure.
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Sean Dobson, MD, Wake Forest University Health Sciences
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
- Physiological Effects of Drugs
- Adrenergic Agents
- Neurotransmitter Agents
- Molecular Mechanisms of Pharmacological Action
- Anti-Arrhythmia Agents
- Central Nervous System Depressants
- Autonomic Agents
- Peripheral Nervous System Agents
- Sensory System Agents
- Anesthetics
- Adrenergic alpha-Agonists
- Adrenergic Agonists
- Membrane Transport Modulators
- Anesthetics, Local
- Voltage-Gated Sodium Channel Blockers
- Sodium Channel Blockers
- Bronchodilator Agents
- Anti-Asthmatic Agents
- Respiratory System Agents
- Adrenergic beta-Agonists
- Sympathomimetics
- Vasoconstrictor Agents
- Mydriatics
- Lidocaine
- Epinephrine
Other Study ID Numbers
Other Study ID Numbers
- IRB00039522
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Anesthesia
-
NCT06076096CompletedAnesthesia | Regional Anesthesia | Anesthesia Management
-
NCT03383770CompletedAnesthesia, Local | Anesthesia | Anesthesia; Adverse Effect
-
NCT01474382CompletedAnesthesia, Local | Dental Anesthesia | Anesthesia, Reversal
-
NCT03833947CompletedAnesthesia | Anesthesia Intubation Complication | Anesthesia; Adverse Effect
-
NCT05834647Not yet recruitingAnesthesia | Anesthesia; Reaction
-
NCT03786211UnknownAnesthesia | Anesthesia; Functional
-
NCT06866886CompletedAnesthesia | Sedation | Anesthesia, Intravenous | Sedation Complication | Recovery From Anesthesia | Monitoring of Depth of Anesthesia
-
NCT07103616Not yet recruitingAnesthesia | Anesthesia; Reaction
Clinical Trials on Thoracic epidural block
-
NCT04835415Completed
-
NCT07273136RecruitingTransversus Abdominis Plane Block | Postoperative Analgesia | Thoracic Epidural Analgesia | Subcostal | Lateral | Major Abdominal Cancer Surgery
-
NCT03460561CompletedAbdominal Cancer
-
NCT01735851Completed
-
NCT06974643RecruitingParavertebral Block | Thoracic Epidural Anesthesia | Awake Thoracotomy
-
NCT03885583Completed
-
NCT03677856UnknownAnesthesia | Thoracic Diseases
-
NCT01755910UnknownBreast Surgery | Autonomic Nervous System | Thoracic Paravertebral Block | HRV
-
NCT04373174CompletedThoracic Surgery | Epidural Anesthesia | Cerebral Oxygen Saturation