Two-unit Cantilever Implant Prostheses Made of Monolithic Zirconia or PFM (Cantilever)
Randomized Controlled Clinical Trial of Two-unit Cantilever Implant Prostheses Made of Monolithic Zirconia on Titanium Base Abutments or Porcelain-fused to Metal on Gold Abutments
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
- Device: Monolithic zirconia screw retained implant-supported cantilever reconstruction supported by titanium base abutments, in a full digital workflow (ZR-TiB)
- Device: porcelain fused-to metal screw retained implant-supported cantilever reconstruction supported by a gold-abutment, in a conventional workflow (PFM-GA)
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: João Pitta, Dr
- Phone Number: +41223794088
- Email: joao.pitta@unige.ch
Study Locations
-
-
-
Geneva, Switzerland, 1211
- Recruiting
- University of Geneva
-
Contact:
- João Pitta, Dr
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Minimal age of 22 years old.
- No general medical condition which represents a contraindication to implant treatment
- Good oral hygiene (PII ≤ 20%), and healthy periodontal tissues (BOP≤ 20%)
- Two adjacent-teeth gap in posterior maxilla or mandible arch (first premolar, second premolar, first molar, second molar) with an osseointegrated regular or wide-diameter bone-level implant in a prosthetically correct position to allow occlusal screw-retention. Free-end edentulous gaps can also be included
- Presence of antagonist occlusal units
Exclusion Criteria:
- Severe bruxism or clenching habits
- Patients with inadequate oral hygiene or persistent intraoral infection
- Women who are pregnant or breast feeding at the day of inclusion
- Smokers exceeding 15 cigarettes / day, or equivalent; patients chewing tobacco
- Unable or unwilling to cooperate for the trial period
- Estimated cantilever crown mesial-distal length > 10 mm
- Estimated implant crown height (from implant platform to occlusal contact points) > 15 mm
Study Plan
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: RANDOMIZED
- Interventional Model: PARALLEL
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
EXPERIMENTAL: ZR-TiB
Monolithic zirconia screw retained implant-supported cantilever reconstruction supported by titanium base abutments, in a full digital workflow (ZR)
|
In group ZR-TiB the implant impressions will be taken using an intra-oral scanner and the respective scanbody.
The restorations will be manufactured by means of CAD/CAM procedures using monolithic zirconia.
For sufficient aesthetics, the zirconia restorations can be manually veneered with veneering ceramic only at the buccal surface, while the occlusal surface will remain monolithic and will be high-gloss polished.
The zirconia restorations will be extra-orally cemented onto titanium base abutments (Straumann® Variobase® for crown, Straumann AG), correctly polished and delivered to the patient, by screw-retention onto the implant.
Other Names:
|
|
ACTIVE_COMPARATOR: PFM-GA
Porcelain fused-to metal screw retained implant-supported cantilever reconstruction supported by a gold-abutment, in a conventional workflow (PFM)
|
In group PFM-GA implant impression will be taken using a polyvinyl siloxane or polyether impression material in a conventional manner with the use of stock trays and corresponding impression copings.
The framework will be manufactured by the lost wax-technique using a gold-abutment (Straumann® Gold abutment for crown, Straumann AG) and a gold-alloy.
All metal frameworks will be manually veneered with veneering ceramic, polished and glazed, and delivered to the patient, by screw-retention onto the implant.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Technical complication rate
Time Frame: 5 years
|
assessed by USPHS-criteria
|
5 years
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Survival rate
Time Frame: 1, 3, 5 years
|
1, 3, 5 years
|
|
|
Biological parameters
Time Frame: 1, 3, 5 years
|
assessed by clinical examination by measuring with a periodontal probe: bleeding on probing (yes/no per site), pocket probing depth (mm), width of keratinized mucosa (mm), assessed by evaluation of standardized x-rays: marginal bone level changes (mm)
|
1, 3, 5 years
|
|
Wear rate of restoration and antagonist
Time Frame: 1, 3, 5 years
|
assessed by a volumetric analysis software
|
1, 3, 5 years
|
|
Patient Reported Outcomes Measures (PROMs)
Time Frame: 1, 3, 5 years
|
assessed through questionnaires: Oral Health Impact Profile (OHIP-14) to evaluate oral health-related quality of life [0-4 for each of the 14 questions, where 4 represents the worst outcome]; Visual Analogue Scales (VAS) to evaluate patient experience with the impression procedure [0-10, where 10 represents the best outcome]
|
1, 3, 5 years
|
|
Cost-efficiency
Time Frame: single-point measure at baseline
|
assessed by measuring time and counting costs of materials between the two workflows procedures (digital vs. analogue)
|
single-point measure at baseline
|
|
Accuracy of fabrication
Time Frame: single-point measure at baseline
|
measured in terms of occlusal adjustment needed between the two fabrication procedures (digital vs. analogue workflow)
|
single-point measure at baseline
|
|
Operator Reported Outcomes Measures
Time Frame: single-point measure at baseline
|
assessed through Visual Analogue Scales (VAS) to evaluate operator experience with the impression procedure and with the adjustment of the restoration [0-10, where 10 represents the best outcome]
|
single-point measure at baseline
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: João Pitta, Dr, University of Genova
- Study Chair: Irena Sailer, Prof, University of Genova
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ANTICIPATED)
Primary Completion
Study Completion (ANTICIPATED)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Cantilver study
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.