Evaluation of the Safety and Efficacy of the Multilayer Stent (STRATO)

April 11, 2014 updated by: Cardiatis

Evaluation du Stent Multicouches Dans le Traitement Des anévrismes de l'Aorte Thoraco-abdominale

Evaluation of the Multilayer Flow Modulator (MFM) for Endovascular Thoracoabdominal Aneurysm Repair.

The objectives of the study is to determine the efficacy, safety and performance of the MFM and its delivery system in patients at high surgical risk presenting with a type II, III thoracoabdominal aneurysm, below the left subclavian and above the iliac bifurcation, according to the Crawford classification.

Study Overview

Detailed Description

Conventional treatments of thoracoabdominal aneurysm are medical treatments (based on hypertension control) on one hand and surgical treatment on the other hand.

The standard treatment is surgery consisting of an exclusion of the aneurysm with restoration of continuity by means of a prosthesis usually made of Dacron.

  • The rates of surgical morbidity and mortality differ according to whether the patient is treated electively or in an emergency setting. The most feared complication is spinal cord ischemia inducing paraplegia.
  • In elective surgery, operative mortality is estimated to be between 6% and 15% depending on the series, and around 50% to 60% of patients are treated in an emergency setting. The rate of neurological complications such as paraparesis or paraplegia is estimated to be between 3% and 15%.
  • In addition to the above, the following major complications have been shown to have an impact on the morbidity of this major surgery (5% each):
  • Bleeding requiring surgical hemostasis
  • Respiratory distress syndrome requiring prolonged ventilation support
  • Acute renal failure
  • Infections
  • Central neurological events (stroke and coma)
  • Peripheral neurological events (sensory-motor deficits, paraparesis, paraplegia)

Analyses identify risk factors increasing the morbidity and mortality:

  • Patients over 80 years
  • Chronic obstructive pulmonary disease
  • Renal failure
  • Coronary artery disease
  • Comorbidities (malignancy, etc.)

Compared to surgery, endovascular stenting reduces:

  • Pulmonary morbidity (suppression of thoracotomy and ventilation), in patients with impaired lung function;
  • Renal dysfunction;
  • Myocardial failure;
  • Risk of spinal cord ischemia and paraplegia.

However, this treatment has a number of limitations

  • Availability of device in case of emergency
  • Topography of the neck must be far enough from the left subclavian artery to allow satisfactory fixation of the stent and exclusion of the lesion;
  • Obstruction of the branches near the aneurysm.

In the current available treatment for this pathology, there are still some disadvantages such as the difficulty of precise positioning of the prosthesis and its branches which must cover the aneurysm tissue without endoleaks. Each lesion having anatomical specificities, the device must be designed for each individual patient, and the operator's technical ability must be extreme. So, the current technique is difficult to reproduce, and any emergency treatment is impossible.

The multilayer flow modulator (non-covered) is the device used in this trial The complications mentioned above are inherent in the concept of covered stent treatment plus endoleaks that continues to fuel the aneurismal sac untreated, thus subject to the persistent risk of rupture. With this technique, the visceral arteries are occluded or have a retrograde flow (which pressurizes the aneurysm again).

The multilayer flow modulator (non-covered) treatment approach avoids the major problems mentioned above:

  • It allows the aneurismal sac to thrombose whilst maintaining the patency of collateral branches arising from the aneurysm;
  • It improves the flow in the collateral branches, which becomes laminar flow through a mechanism of hemodynamic pressure drop from layer to layer and an increase in speed by rolling;
  • Deployment is easier and it is not different from peripheral stent deployment;
  • The device is available in all sizes and all lengths that can be stored, allowing the management of emergencies.

The space-age 3D geometrical design of a Cardiatis multilayer flow modulator modifies flow within the aorta in a way that reduces pressure within the aneurysm thus collapsing the aneurismal sac while preserving any vital collateral circulation.

Study Type

Interventional

Enrollment (Actual)

23

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Besançon, France, 25030
        • Hôpital Jean Minjoz
      • Bron, France, 69677
        • Hopital Neurocardiologique
      • Metz-Tessy, France, 74370
        • Centre Hospitalier de la Région d'Annecy
      • Nancy, France, 54511
        • Chu Brabois Nancy
      • Paris, France, 75015
        • Hopital Europeen Georges-Pompidou
      • Paris, France, 75651
        • Pitié-Salpêtrière
      • Paris, France, 78150
        • CMC Parly II
      • Quincy-sous-Sénart, France, 91480
        • Institut Cardio-Vasculaire Paris Sud Hôpital Claude Galien À Quincy
      • Toulouse, France, 31059
        • Hopital Universitaire Rangueil

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Age >18 years
  • Life expectancy ≥ 12 months
  • The patient or his legal representative has signed the informed consent form
  • Thoracoabdominal aneurysm type 2 or 3 with vital collaterals and requiring intervention to prevent its rupture according to the criteria defined by consensus ("Expert Consensus Document on the Treatment of Descending Thoracic Aortic Disease Using Endovascular Stent-Grafts", Ann Thorac Surg 2008;85:S1-41)
  • Contraindicated for open surgery, declared inoperable by the surgeon and anesthetist (statement signed by each doctor) and must have at least one of the following:

    1. Age > 80 years
    2. ASA (American Society of Anesthesiologists) score ≥ 3
    3. History of thoracic surgery or surgery of the abdominal aorta
    4. Coronary artery disease (history of angina or myocardial infarction) with positive functional testing and coronary lesions for which revascularization is impossible or not indicated
    5. Heart failure
    6. Inoperable aortic stenosis
    7. LVEF (Left Ventricular Ejection Fraction) <40%;
    8. chronic respiratory failure defined by one of the following criteria:

      1. FEV (Forced expiratory volume) <1.2 l / sec;
      2. VC (Vital Capacity) <50% of the predicted value according to age, sex and weight;
      3. arterial blood gas analysis in the absence of oxygen: PaCO2 (Pression artérielle en CO2) > 45 mmHg or PaO2 (Pression artérielle en O2) <60 mmHg
      4. Oxygen therapy
    9. renal insufficiency if creatininaemia> 200 micromol / l before injection of contrast product;
    10. hostile abdomen, including presence of ascites or other signs of portal hypertension;
    11. obesity.
  • adequate arterial anatomy of aneurismal lesion access.

Exclusion Criteria:

  • medical contraindications to a local or general anesthesia and angiography;
  • Life expectancy less than one year, or clinical follow-up impossible;
  • congenital disorders of blood coagulation;
  • intercurrent infection;
  • allergy to aspirin, clopidogrel, or contrast agents;
  • patient(s) included in another clinical study;
  • patient pregnant or breastfeeding

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: TREATMENT
  • Allocation: NA
  • Interventional Model: SINGLE_GROUP
  • Masking: NONE

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
EXPERIMENTAL: Thotaco-abdominal aneurysm
MFM
Implantation of the MFM
Other Names:
  • Multilayer Flow Modulator
  • Multilayer stent

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Time Frame
Number of patients with aneurysm exclusion
Time Frame: 12 months
12 months

Secondary Outcome Measures

Outcome Measure
Time Frame
Number of covered branches permeable
Time Frame: 12 months
12 months
Number of patients with Serious Adverse Events
Time Frame: 12 months
12 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Investigators

  • Principal Investigator: Jean-Noël Fabiani, Pr, HEGP

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

March 1, 2010

Primary Completion (ACTUAL)

April 1, 2012

Study Completion (ACTUAL)

April 1, 2012

Study Registration Dates

First Submitted

December 14, 2012

First Submitted That Met QC Criteria

December 20, 2012

First Posted (ESTIMATE)

December 28, 2012

Study Record Updates

Last Update Posted (ESTIMATE)

April 14, 2014

Last Update Submitted That Met QC Criteria

April 11, 2014

Last Verified

April 1, 2014

More Information

Terms related to this study

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Aortic Aneurysm, Thoracic

Clinical Trials on MFM

3