11C Methionine PET for the Detection of Hyperfunctional Parathyroid Tissues

September 16, 2015 updated by: University of British Columbia

Pre-operative Parathyroid Imaging: a Comparison of 11C-Methionine PET, 18F-FDG PET AND SPEC-CT for the Detection of Hyperfunctional Parathyroid Tissues

The overall sensitivity and specificity of 11C-MET PET/CT is superior to 18F-FDG PET/CT and conventional SPECT-CT for the detection of abnormal parathyroid glands.

Study Overview

Detailed Description

STUDY OBJECTIVES Primary: To compare the accuracy, sensitivity and specificity of 11C-methionine (MET) PET/CT and 99mTc-MIBI SPECT-CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism.

Secondary:To compare the accuracy, sensitivity and specificity of 11C-MET and 18F-FDG PET/CT scans in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism.

STUDY DESIGN A phase II diagnostic imaging, single-centre study to compare the accuracy of 11C-MET PET/CT with standard 99mTc-MIBI SPECT-CT and with 18F-FDG PET/CT imaging in patients with primary hyperparathyroidism.

STUDY POPULATION Number of Subjects: 50 patients Number of groups: 1: 50 with primary hyperparathyroidism. Age/Gender: Age greater than or equal to 19 years / Male and Female Study specific requirements: Subjects with clinically suspected primary hyperparathyroidism who require 99mTc-MIBI SPECT-CT parathyroid imaging.

INVESTIGATIONAL PRODUCT Product: 11C-Methionine Route of administration: Intravenous Dosage(s) and frequency: Radioactive dose of 11C-Methionine of 6 MBq per kilogram body weight per injection (maximum dose of 555 MBq); one injection per patient.

COMPARATOR PRODUCTS Product: 99mTc-Methoxyisobutylisonitrite; 18F-Fluorodeoxyglucose Route of administration: Intravenous Dosage(s) and frequency: (1) Radioactive dose of 99mTc-Methoxyisobutylisonitrite of 555 - 740 MBq per injection; one injection per patient. (2) Radioactive dose of 18F-Fluorodeoxyglucose of 296 - 521 MBq per injection; one injection per patient.

EVALUATION CRITERIA Efficacy: The comparison of the accuracy, sensitivity, and specificity of 11C-MET PET/CT with 99mTc-MIBI SPECT-CT and 18F-FDG PET/CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism.

Safety: Vital signs before and following 11C-MET administration; adverse events collection.

Study Type

Interventional

Enrollment (Anticipated)

50

Phase

  • Phase 2

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

    • British Columbia
      • Vancouver, British Columbia, Canada, V5Z 4E6
        • Recruiting
        • British Columbia Cancer Agency
        • Contact:
        • Sub-Investigator:
          • Don Wilson, MD, FRCPC

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

16 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Adults > age 18;
  • Able to provide written informed consent;
  • Subjects with biochemical evidence, including elevated serum calcium and PTH levels, of primary hyperparathyroidism.

Exclusion Criteria:

  • Subjects with previous successful parathyroidectomy and parathyroid tissue reimplantation;
  • Pregnancy;
  • Subjects who are unable to tolerate the physical/logistical requirements of completing two PET/CT scans, including lying still for a prolonged period of time and receiving two intravenous injections.
  • Subjects who exceed the safe weight limit of the PET/CT bed (204.5 kg) or who cannot fit through the PET/CT machine (diameter 70cm).

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: Non-Randomized
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Primary hyperparathyroidism
Subjects with biochemical evidence, including elevated serum calcium and PTH levels, of primary hyperparathyroidism. All patients will undergo 11C-methionine PET/CT, SPECT-CT and 18F-FDG PET/CT scanning.
PET with the radiopharmaceutical carbon-11 methionine (11C-MET) has been considered to improve diagnosis due to a superior spatial resolution and higher specificity compared to other radiotracers such as 18F-FDG. For the 11C-MET PET/CT, the patient will receive an intravenous bolus injection of 11C-MET as manufactured at the BCCA production facility at a dose of 6 (0.16 mCi) MBq per kilogram but not to exceed 555 MBq (15 mCi).
Other Names:
  • 11C-MET
For PET/CT scans, the patient will first receive an intravenous bolus injection of 18F-FDG as manufactured at the BCCA production facility in a dose determined by body weight but not to exceed 521 MBq (14.1 mCi). Our standard adult prescription (70kg adult) for 18F-FDG is 296 MBq (8.0 mCi). The target dose for body scans is increased by 59.2 MBq (1.6 mCi) for every 20 kg increase in body weight to a maximum target dose of 474 MBq (12.8 mCi).
For the SPECT-CT scan, each injection of intravenous 99mTc-MIBI is dosed at a maximum of 20 mCi (740MBq), as per usual standard of care. The energy window of each scan is at 140 keV, consistent with the standard of SPEC-CT imaging techniques.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
To compare the sensitivity of 11C-MET PET/CT, SPECT-CT and 18F-FDG PET/CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism
Time Frame: Patient will undergo the scans at baseline
Sensitivity is the percentage of patients that were correctly identified to have an abnormal parathyroid gland by the imaging studies.
Patient will undergo the scans at baseline
To compare the specificity of11C-MET PET/CT, SPECT-CT and 18F-FDG PET/CT in the detection of pathologic parathyroid glands in patients with primary hyperparathyroidism
Time Frame: Patient will undergo the scans at baseline
Specificity is defined as the percentage of patients that were correctly rejected for having an abnormal parathyroid gland by the imaging studies.
Patient will undergo the scans at baseline

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
To evaluate the safety profile of 11C-MET PET/CT.
Time Frame: Up to 2 weeks
All adverse events will be recorded. An Adverse Event (AE) is any untoward, undesired, unplanned medical occurrence in a participant and does not necessarily have a causal relationship with the study intervention. Expected adverse events from PET/CT scans include bruising, bleeding or infection at the site of intravenous radiotracer injection. Other expected adverse events include feeling of discomfort or claustrophobia from being in the scanner.
Up to 2 weeks

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Donald W Anderson, MD, FRCSC, University of British Columbia; Vancouver General Hospital
  • Principal Investigator: Don Wilson, MD, FRCPC, British Columbia Cancer Agency

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

May 1, 2014

Primary Completion (Anticipated)

March 1, 2018

Study Completion (Anticipated)

July 1, 2018

Study Registration Dates

First Submitted

January 4, 2013

First Submitted That Met QC Criteria

January 31, 2013

First Posted (Estimate)

February 4, 2013

Study Record Updates

Last Update Posted (Estimate)

September 18, 2015

Last Update Submitted That Met QC Criteria

September 16, 2015

Last Verified

September 1, 2015

More Information

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Primary Hyperparathyroidism

Clinical Trials on 11C-Methionine PET/CT scanning

3
Subscribe