Central Line Placement-EVALUATION OF LINE DEPTH AS A FACTOR IN NEED FOR LINE REPLACEMENT SECONDARY TO MALPOSITION

January 14, 2020 updated by: Marcus Jarboe, University of Michigan

Central Line Placement Study -EVALUATION OF LINE DEPTH AS A FACTOR IN NEED FOR LINE REPLACEMENT SECONDARY TO MALPOSITION

This is a single center, randomized, controlled trial in which tunneled central line catheters will be placed in two distinct, select positions. The catheter tip position will then be followed up prospectively after placement to determine whether there is any malpositioning of the tip and if one placement is better than the other.

Study Overview

Detailed Description

Optimal central line placement is vital to catheter longevity. If malpositioned, the catheter may need to get replaced, potentially causing additional morbidity to the patient and additional cost to the healthcare system. In our department, a retrospective study looking at catheter tip position at inital placement and incidence of malposition. In this study, 404 catheter placements were reviewed, and a total of 162 (40.1%) were replaced. Out of the 162 replaced, 36 (22.2%) were replaced secondary to malposition. From this study, we were also able to conclude that catheter tips placed in a deeper position, approximately one and a half vertebral bodies below the carina, were less likely to be malpositioned in the future upon radiographic review.

Current standard of care does not dictate positioning of the line in a specific loacation. In the presence of these findings, we are proposing to conduct a single center randomized control trial in which tunneled central line catheters will be placed in two distinct, select positions. After informed consent is obtained from the patient and family, they will be randomized to one of two treatment groups. The shallow group will have the tip of the catheter located approximately one vertebral body above the carina. The deep group will have the catheter tip placed 1.5 to 2.5 vertebral bodies below the carina. Central line placement will be performed under fluoroscopy in the operating room to optimize catheter placement. Chest X ray in the post operative area will be used to confirm catheter tip position. The catheter tip position will then be followed up prospectively using chest X ray films at or within three months after placement to determine whether there is any malpositioning of the tip.

Study Type

Interventional

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Michigan
      • Ann Arbor, Michigan, United States, 48109
        • The University of Michigan

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

No older than 18 years (Child, Adult)

Accepts Healthy Volunteers

Yes

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Children from 0-18 years of age needing a tunneled central line (port or broviac) for treatment of their disease.

Exclusion Criteria:

  • Wire exchanged lines
  • Non ultrasound placed lines, femoral lines, saphenous vein lines, and cut downs
  • Short gut syndrome children < 1 year of age

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Supportive Care
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Shallow catheter tip placement
Patients randomized to shallow tip placement will have the tip of the catheter placed approximately one vertebral body above to even with the carina.
for shallow placement tip of catheter placed 1 vertebral body above to even with the carina
Experimental: Deep catheter tip placement
Patients randomized to deep tip placement will have the tip of the catheter placed 1.5 to 2.5 vertebral bodies below the carina.
deep placement catheter tip is placed 1.5 to 2.5 vertebral bodies below the carina

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Malposition
Time Frame: 90 days
The primary outcome measure of this study is to determine whether the position of the tip during central line placement plays a role in malposition during further evaluation of these patients. This will be determined with chest X-ray done at or within 90 days after line insertion. All non-ultrasound guided lines and those placed by cut down procedure will be tallied in a prospective manner to calculate the number of lines placed without radiological guidance. Number of attempts required to place the line (number of times the needle is removed exterior to the skin, i.e. number of skin punctures.)
90 days

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Marcus Jarboe, University of Michigan

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Anticipated)

December 1, 2019

Primary Completion (Anticipated)

December 28, 2020

Study Completion (Anticipated)

December 28, 2021

Study Registration Dates

First Submitted

November 9, 2015

First Submitted That Met QC Criteria

November 9, 2015

First Posted (Estimate)

November 11, 2015

Study Record Updates

Last Update Posted (Actual)

January 18, 2020

Last Update Submitted That Met QC Criteria

January 14, 2020

Last Verified

January 1, 2020

More Information

Terms related to this study

Other Study ID Numbers

  • 98248

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Vascular Access Complication

Clinical Trials on Shallow catheter tip placement

Subscribe