Optimal Left Ventricular Lead Positioning During Cardiac Resynchronisation Therapy; Comparison of Two Methods of Targeting

July 3, 2019 updated by: Peter J Pugh

Cardiac Resynchronisation Therapy (CRT) is a well-known treatment for patients with heart failure. It is a special pacemaker that consists of three pacing wires, which are implanted in the right upper and bottom chambers of the heart and via a vein on the surface of the main pumping chamber (left bottom chamber). CRT helps by improving co- ordination between the top and the bottom chambers of the heart. By stimulating the heart from the left and right bottom chambers, co-ordination can be restored and heart function as well as symptoms improve. It is known that up to 30-40% of patients of patients undergoing CRT pacemaker implantation do not attain any benefit. Given the inherent risks and costs of pacemaker implantation and maintenance, a reduction in the rate of CRT "non-responders" is an important goal.

It has been suggested that presence of scar tissue in the heart and suboptimal placement of the pacing wire on the top of the main pumping chamber can explain this poor response. The best place to position the pacing wire on the surface of the main pumping chamber is the area that contracts last and it can be identified using ultrasound scan of the heart.

Unfortunately, ultrasound is not always possible to help identifying the best area and only a minority of hospitals are able to use this method. Therefore we aim to investigate alternative ways of positioning the pacing wire in the best possible area of the main pumping heart chamber. Investigators propose to measure electrical signals as an alternative and more effective way in positioning the wire in the most effective area. Investigators aim to look at the relationship between the best area identified by ultrasound scan and by electrical signals and also use electrical signals to avoid areas of scar.

Study Overview

Detailed Description

Cardiac Resynchronisation Therapy (CRT) reduces both morbidity and mortality in selected patients with left ventricular dysfunction and intraventricular conduction delay who remain symptomatic despite optimal medical therapy.

It is known that up to 30% of patients of patients undergoing CRT implantation do not attain symptomatic benefit . Given the inherent risks and costs of device implantation and maintenance, a reduction in the rate of CRT "non-responders" is an important goal.

Factors associated with a poor outcome include presence of myocardial scar, and suboptimal Left Ventricular (LV) lead placement.

Pacing the LV at the most delayed LV region promotes contractile synchrony resulting in more effective and energetically efficient ejection, geometric remodelling with reduced LV end-systolic volume and improved cardiac function.

Studies using transthoracic echocardiographic (TTE) parameters to target the LV lead positioning have shown that an optimal LV lead position at the site of latest mechanical activation, avoiding low strain amplitude (scar), was associated with superior response to CRT and improved survival that persisted during follow-up.

It remains unclear whether the site of latest mechanical activation is related to the site of latest electrical activation, nor whether sensed electrical signals correspond to sites of scar. The site of latest electrical activation is assessed during CRT implant by measuring electrical activation (LV electrical delay) of the LV at different sites in relation to the first deflection of the QRS complex of the surface electrocardiogram (ECG).

A recent study evaluated the relationship between LV electrical delay and CRT outcomes/ response to CRT and concluded that electrical dyssynchrony was strongly and independently associated with reverse remodelling and led to improvement in the Quality of Life with CRT.

Despite TTE being an effective way of assessing optimal LV lead positioning for identifying mechanical activation, it is expensive, images can be suboptimal and usually requires an extra visit prior to implantation, therefore an intraprocedural way of identifying the optimal areas could be beneficial.

It is not known whether lead position as targeted by imaging methods of mechanical activation corresponds to the site of latest electrical activation, nor whether sensed electrical signals correspond to sites of scar. Investigators are planning to investigate the relationship between the site of latest mechanical activation using TTE and the site of latest electrical activation of the LV; and between scar and sensed electrical signals.

If the area of latest mechanical activation is related to the area of latest electrical activation then this can be an alternative, more convenient and cost effective way of assessing optimal LV lead positioning.

Study Type

Observational

Enrollment (Anticipated)

40

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

16 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Probability Sample

Study Population

Patients with HF, LBBB and have been referred for CRT.

Description

Inclusion Criteria:

  1. LV Ejection Fraction ≤ 35 %
  2. New York Heart Association class I-IV
  3. QRS ≥130ms
  4. Left Bundle Branch Block
  5. Male or female, aged 18 years or above
  6. Able to give consent

Exclusion Criteria:

  1. Patients with Atrial Fibrillation
  2. Unable to give consent
  3. QRS≤120 ms
  4. Right Bundle Branch Block

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Observational Models: Case-Control
  • Time Perspectives: Prospective

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
Echocardiographic targeting
Electrogram targeting
Measurement of electrical signal in the heart during implantation of CRT, by positioning the lead in different places in the heart.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Q-LV (electrical activation of the left ventricle) at different sites of the left ventricle
Time Frame: 1 day
The time from onset of depolarisation (Q wave) to sensed electrogram in the left ventricle ("LV") will be measured at various sites over the left ventricular epicardium to build up a map of myocardial electrical activation
1 day

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Mechanical activation of the left ventricle using echocardiography
Time Frame: 1 day
The pattern of mechanical activation of the left ventricle will be determined using speckle-tracking echocardiography.
1 day

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Anticipated)

August 1, 2019

Primary Completion (Anticipated)

October 1, 2021

Study Completion (Anticipated)

December 1, 2021

Study Registration Dates

First Submitted

August 19, 2018

First Submitted That Met QC Criteria

December 6, 2018

First Posted (Actual)

December 7, 2018

Study Record Updates

Last Update Posted (Actual)

July 5, 2019

Last Update Submitted That Met QC Criteria

July 3, 2019

Last Verified

July 1, 2019

More Information

Terms related to this study

Additional Relevant MeSH Terms

Other Study ID Numbers

  • 227862

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

No

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Heart Failure

Clinical Trials on Measurement of electrical delay during LV lead placement

3
Subscribe