- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT04209972
The Benefit of UHR-CT: Precision of Repeated Volume Measurements of Pulmonary Nodules (Coffee Break)
The Benefit of Ultra-high Resolution Computed Tomography: Precision of Repeated Volume Measurements of Pulmonary Nodules
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
Rationale: Ultra-high resolution computed tomography (UHRCT) produces radiological images with a spatial resolution of 0.25 mm in a matrix of 1024x1024. This should decrease measurement variation of nodule growth as a marker of malignancy, by making nodule delineation more precise for automatic volumetry segmentation and volume doubling time assessment than in conventional CT. If possible, this can shorten follow up of incidental pulmonary nodules to exclude malignancy, with less medicalisation and patient anxiety.
Objective: To assess the variability of semi-automated volume measurements of pulmonary nodules in patients with known or suspected pulmonary metastases on same-day repeated scans of equal radiation dose from two different CT scanners: CT scanner with standard spatial resolution (conventional CT, CT1) and UHRCT (CT2).
Study design: This is a single center prospective trial on 80 patients with known or suspected pulmonary metastases who are scheduled for chest and/or abdominal CT. Study participants will undergo two additional partial chest CT scans on either CT 1 or CT 2 for research purpose only, at similar radiation dose. Patients are equally divided across CT 1 and 2.
Study population: Patients who are 18 years or older with known solid pulmonary nodules compatible with metastases and who are willing and able to give informed consent are eligible. Patients are excluded if they have less than two eligible pulmonary nodules with a z range of 16 cm. Nodules with calcifications, surrounding opacities, or vessel- or pleural abutment will be excluded from analysis.
Main study parameters/endpoints: The main endpoint of this study is the upper limit of the 95% confidence interval of repeated semi-automated nodule volume measurements of both CT scanners.
Nature and extent of the burden and risks associated with participation, benefit and group relatedness:
CT imaging is associated with risks related to the use of ionizing radiation. The CT protocol including the scheduled CT scan and the additional scans in this study has been carefully designed to have a total radiation dose at the same level as the achievable diagnostic reference level of chest CT in the Netherlands, which is 542 mGycm in 2013 (1). The burden associated with the two extra study CT acquisitions comprises a dose length product (DLP) of 120.4 mGy•cm for research (1.7 mSv, which is lower than the background radiation of one year in the Netherlands, with a conversion factor of 0.014 from Deak et al (2)).
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Gelderland
-
Nijmegen, Gelderland, Netherlands, 6500 HB
- Radboudumc
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- 18 years of age or older
- A solid primary tumour anywhere in the body and solid, noncalcified nodules in the pulmonary parenchyma on previous CT scans suspected for pulmonary metastases, according to radiological reports
- Two lung nodules that do not abut vessels or pleura with a two dimensional diameter between 5 and 10 mm within a distance of each other of 16 cm in the craniocaudal direction
Exclusion Criteria:
- Immobility (not able to stand up and get off the scanner table)
- Patients who received local pulmonary treatment: Radiotherapy, Excision, Ablation
- Patients with radiologically suspected lymphangitis carcinomatosa or consolidations around the nodules.
- Patients who only have calcified pulmonary nodules or nodules that abut vessels or pleura.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Active Comparator: Patients on CT1
Patients will undergo two pre-contrast scans, and will be in between the two scans be off and on the table at a standard CT scanner.
(Aquilion One Genesis, Canon Medical Systems)
|
Patients will be divided on one of the two CT scanners.
This group will be scanned on the Aquilion one Genesis.
|
|
Active Comparator: Patients on CT2
Patients will undergo two pre-contrast scans, and will be in between the two scans be off and on the table at a UHRCT scanner.
(Aquilion One Precision, Canon Medical Systems)
|
Patients will be divided on one of the two CT scanners.
This group will be scanned on the Precision CT scanner.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The main endpoint of this study is the difference in precision in millimeter between the two CT scanners.
Time Frame: 4 months
|
The precision of each scanner is obtained by the standard deviation between the two measurements.
The difference between scanners is tested with an F-test and the precision of each scanner is shown by a Bland-Altman plot
|
4 months
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Evaluation of image quality (segmentation errors)
Time Frame: 5 months
|
Evaluate the image quality of the scans
|
5 months
|
|
Evaluation of image quality (motion artefacts)
Time Frame: 5 months
|
Evaluate the image quality of the scans
|
5 months
|
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Patient characteristics (age)
Time Frame: 4 months
|
Patient characteristics (age)
|
4 months
|
|
Patient characteristics (height)
Time Frame: 4 months
|
Patient characteristics (height)
|
4 months
|
|
Patient characteristics (weight)
Time Frame: 4 months
|
Patient characteristics (weight)
|
4 months
|
|
Radiation dose
Time Frame: 4 months
|
Radiation dose
|
4 months
|
Collaborators and Investigators
Investigators
- Principal Investigator: Monique Brink, PhD, MD, Radboud University Medical Center
Publications and helpful links
General Publications
- Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307-10.
- Tanaka R, Yoshioka K, Takagi H, Schuijf JD, Arakita K. Novel developments in non-invasive imaging of peripheral arterial disease with CT: experience with state-of-the-art, ultra-high-resolution CT and subtraction imaging. Clin Radiol. 2019 Jan;74(1):51-58. doi: 10.1016/j.crad.2018.03.002. Epub 2018 Apr 5.
- van der Molen AJ, Schilham A, Stoop P, Prokop M, Geleijns J. A national survey on radiation dose in CT in The Netherlands. Insights Imaging. 2013 Jun;4(3):383-90. doi: 10.1007/s13244-013-0253-9. Epub 2013 May 15.
- Deak PD, Smal Y, Kalender WA. Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product. Radiology. 2010 Oct;257(1):158-66. doi: 10.1148/radiol.10100047.
- Alpert JB, Ko JP. Management of Incidental Lung Nodules: Current Strategy and Rationale. Radiol Clin North Am. 2018 May;56(3):339-351. doi: 10.1016/j.rcl.2018.01.002. Epub 2018 Mar 7.
- MacMahon H, Naidich DP, Goo JM, Lee KS, Leung ANC, Mayo JR, Mehta AC, Ohno Y, Powell CA, Prokop M, Rubin GD, Schaefer-Prokop CM, Travis WD, Van Schil PE, Bankier AA. Guidelines for Management of Incidental Pulmonary Nodules Detected on CT Images: From the Fleischner Society 2017. Radiology. 2017 Jul;284(1):228-243. doi: 10.1148/radiol.2017161659. Epub 2017 Feb 23.
- Baldwin DR, Callister ME; Guideline Development Group. The British Thoracic Society guidelines on the investigation and management of pulmonary nodules. Thorax. 2015 Aug;70(8):794-8. doi: 10.1136/thoraxjnl-2015-207221. Epub 2015 Jul 1.
- Devaraj A, van Ginneken B, Nair A, Baldwin D. Use of Volumetry for Lung Nodule Management: Theory and Practice. Radiology. 2017 Sep;284(3):630-644. doi: 10.1148/radiol.2017151022.
- Wormanns D, Kohl G, Klotz E, Marheine A, Beyer F, Heindel W, Diederich S. Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility. Eur Radiol. 2004 Jan;14(1):86-92. doi: 10.1007/s00330-003-2132-0. Epub 2003 Nov 13.
- Gietema HA, Schaefer-Prokop CM, Mali WP, Groenewegen G, Prokop M. Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT-- influence of inspiration level, nodule size, and segmentation performance. Radiology. 2007 Dec;245(3):888-94. doi: 10.1148/radiol.2452061054. Epub 2007 Oct 8.
- Goodman LR, Gulsun M, Washington L, Nagy PG, Piacsek KL. Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements. AJR Am J Roentgenol. 2006 Apr;186(4):989-94. doi: 10.2214/AJR.04.1821.
- Hein PA, Romano VC, Rogalla P, Klessen C, Lembcke A, Bornemann L, Dicken V, Hamm B, Bauknecht HC. Variability of semiautomated lung nodule volumetry on ultralow-dose CT: comparison with nodule volumetry on standard-dose CT. J Digit Imaging. 2010 Feb;23(1):8-17. doi: 10.1007/s10278-008-9157-5. Epub 2008 Sep 5.
- Han D, Heuvelmans MA, Oudkerk M. Volume versus diameter assessment of small pulmonary nodules in CT lung cancer screening. Transl Lung Cancer Res. 2017 Feb;6(1):52-61. doi: 10.21037/tlcr.2017.01.05.
- Zhou W, Montoya J, Gutjahr R, Ferrero A, Halaweish A, Kappler S, McCollough C, Leng S. Lung Nodule Volume Quantification and Shape Differentiation with an Ultra-High Resolution Technique on a Photon Counting Detector CT System. Proc SPIE Int Soc Opt Eng. 2017 Feb 11;10132:101323Q. doi: 10.1117/12.2255736. Epub 2017 Mar 9.
- de Hoop B, Gietema H, van Ginneken B, Zanen P, Groenewegen G, Prokop M. A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: what is the minimum increase in size to detect growth in repeated CT examinations. Eur Radiol. 2009 Apr;19(4):800-8. doi: 10.1007/s00330-008-1229-x. Epub 2008 Nov 19.
- Leng S, Gutjahr R, Ferrero A, Kappler S, Henning A, Halaweish A, Zhou W, Montoya J, McCollough C. Ultra-High Spatial Resolution, Multi-Energy CT using Photon Counting Detector Technology. Proc SPIE Int Soc Opt Eng. 2017 Feb 11;10132:101320Y. doi: 10.1117/12.2255589. Epub 2017 Mar 9.
- Kalra MK, Sodickson AD, Mayo-Smith WW. CT Radiation: Key Concepts for Gentle and Wise Use. Radiographics. 2015 Oct;35(6):1706-21. doi: 10.1148/rg.2015150118.
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- NL67905.091.18
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Pulmonary Nodule, Solitary
-
Vanderbilt University Medical CenterActive, not recruitingPeripheral Pulmonary Lesion | Lung Nodule, SolitaryUnited States
-
Biodesix, Inc.CompletedNSCLC | Nodule Solitary PulmonaryUnited States
-
Biodesix, Inc.Active, not recruitingNon-small Cell Carcinoma | Nodule Solitary PulmonaryUnited States, Canada
-
Geneplus-Beijing Co. Ltd.Beijing Hospital; Emergency General HospitalCompletedPulmonary Nodule, Solitary | Whole-genome Methylation SequencingChina
-
University Medical Center GroningenRecruitingPulmonary Nodules, SolitaryNetherlands
-
RenJi HospitalNot yet recruitingPulmonary Nodule, Solitary | Pulmonary Nodule, Multiple
-
Fox Chase Cancer CenterUnited States Department of Defense; Creatv Microtech, Inc.TerminatedPulmonary Nodule, Solitary | Pulmonary Nodule, MultipleUnited States
-
Southern Adelaide Local Health NetworkActive, not recruitingPulmonary Nodule, Solitary | Pulmonary Nodule, MultipleAustralia
-
UNC Lineberger Comprehensive Cancer CenterNational Cancer Institute (NCI)CompletedPulmonary Nodule, Solitary | Pulmonary Nodule, MultipleUnited States
-
GuiBin QiaoActive, not recruitingPulmonary Nodule, Solitary | Pulmonary Nodule, MultipleChina
Clinical Trials on Genesis high-end CT scanner
-
University Health Network, TorontoCompletedComputed Tomography | Image Quality
-
Cliniques universitaires Saint-Luc- Université...Recruiting
-
University of LiegeRecruitingBone Loss | Kidney Transplant; ComplicationsBelgium
-
Indiana Kidney Stone InstituteNational Kidney Foundation; Indiana University School of MedicineCompleted
-
University Hospital AugsburgRecruitingNeoplasms | Neoplasm Metastasis | Metastatic CancerGermany
-
GE HealthcareCompleted
-
Medical University of South CarolinaTerminated
-
Assistance Publique - Hôpitaux de ParisURC-CIC Paris Descartes Necker CochinCompleted
-
National Institutes of Health Clinical Center (CC)CompletedVascular Diseases | Cancer | Metabolic Bone Disease | Inflammatory DiseaseUnited States