Continuous Glucose Monitoring in At-Risk Newborns

August 12, 2025 updated by: Natalie Allen, Milton S. Hershey Medical Center

Continuous Glucose Monitoring in At-Risk Newborns: A Feasibility Study

Hypoglycemia (low blood glucose) is a very common problem in newborns, and has been associated with poor neurodevelopment, cognition, and school performance. At-risk newborns (infants of diabetic mothers [IDM], large [LGA] and small [SGA] for gestational age infants, and late preterm [LPT] infants) undergo a hypoglycemia screening protocol that involves numerous intermittent needle sticks to test glucose levels on bedside glucometers; however, continuous glucose monitoring (CGM, currently not approved for clinical use in babies), via a small sensor placed in the thigh (only 1 needle stick), would likely decrease pain while providing continuous glucose levels. This study will evaluate the feasibility, safety, and precision of CGM in at-risk newborns, and determine if this method would decrease the amount of painful procedures and episodes of hypoglycemia missed by intermittent sampling.

As part of regular medical care, participants will undergo intermittent blood glucose screening with heel sticks as per the current hospital standard of care protocol. Regular medical care involves checking the participant's blood glucose via heel stick every few hours using a bedside glucometer, with another heel stick to confirm low values in the laboratory. If the participant has low values, he/she may be treated with oral glucose gel, feedings of breast milk or formula, or intravenous (IV) fluids in the Neonatal Intensive Care Unit (NICU). This research study involves placing a CGM device in addition to undergoing the current blood glucose screening protocol and treatment.

As soon as possible after birth, a continuous glucose monitoring device (Dexcom G7) will be placed on the participant's thigh by a research team member, and will blindly continuously record glucose levels that will be analyzed after discharge. Everyone who agrees to participate in this study will have placement of this experimental device.

The investigational device will stay in place for the same amount of time that a participant is undergoing blood glucose monitoring as per the current standard of care protocol, for a maximum of 7 days. A participant may need to have his/her blood glucose checked after 7 days for regular medical care (and not for research), because his/her glucose concentrations are still low. Being in the research study will not affect a participant's medical care, and will not affect how long he/she needs blood glucose monitoring or treatment.

A research team member will place and remove the CGM. Nurses will evaluate the site of the device for signs of irritation, infection, bleeding, and any other issues at least 3 times per day. After discharge from the hospital, data will be collected from the participant's medical record and participant's mother's medical record, including the participant's sex and birth weight, blood glucose values, details of feedings, treatments given for low glucose concentrations, and NICU admission data. Data that will be collected from the participant's mother's medical record includes age and race, prenatal data, medical history, and medication use. The participant's parents will be asked to fill out a short survey about their experience with this device when it is removed.

Study Overview

Status

Recruiting

Study Type

Interventional

Enrollment (Estimated)

100

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Contact Backup

  • Name: Kerry Deitrick, LPN

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

1 minute to 2 weeks (Child)

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • At-risk newborns (<48 hours old, all sexes) admitted to the Newborn Nursery or the NICU who meet any of the below criteria:

    1. Infant of a diabetic mother (IDM, pre-existing or gestational diabetes)
    2. Large for gestational age (LGA, >90th percentile [sex-specific])
    3. Small for gestational age (SGA, <10th percentile [sex-specific])
    4. Late preterm (LPT, 34 0/7 to 36 6/7 weeks' gestation)
  • Any newborn undergoing routine blood glucose screening in the newborn nursery per the Neonatal Hypoglycemia protocol (includes newborns of mothers taking oral hypoglycemic agents, beta-blocker medications, or systemic steroids within 7 days before delivery; and newborns with clinical manifestations of hypoglycemia)

Exclusion Criteria:

  • Birth weight <2kg
  • hypoxic-ischemic encephalopathy
  • a contraindication to oral feeding
  • abnormal skin that will preclude placement of the CGM (e.g., skin on the thigh that is not intact)
  • chromosomal abnormalities or severe congenital anomalies identified ante- or postnatally
  • infants who are not expected to survive or who are in extremis
  • additional risk of immunocompromise, including:

    1. Skin infections, such as staphylococcus or streptococcus skin infections and herpes (skin, eye, and mouth disease) infection
    2. Skin diseases that add additional risk, such as epidermolysis bullosa, ichthyosis, peeling skin syndrome, and hemangiomas
    3. Systemic sepsis, viral syndromes
    4. Immune diseases such as severe combined immunodeficiency, cancer, T-cell or B-cell deficiencies, inborn errors of metabolism, chromosomal abnormalities, glycogen storage diseases, genetic diseases
    5. Abdominal wall defects

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Continuous Glucose Monitoring
All participants will have the continuous glucose monitoring device placed.
The Dexcom G7 Glucose Monitoring System (San Diego, CA) reports continuous interstitial blood glucose concentrations every 5 minutes, does not require calibration, and involves only 1 needle stick to place the sensor. The manufacturer recommends that a single sensor may be used for up to 10 days. The Dexcom G7 system is the only FDA approved CGM system for children (age >2 years).
Other Names:
  • Dexcom G7

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Agreement of blood glucose concentrations from CGM vs intermittent monitoring
Time Frame: 1-7 days
Bland-Altman analysis to evaluate bias and the agreement interval between CGM and intermittent testing
1-7 days
Likert-scale questionnaire results from parents, nurses, and research team
Time Frame: 7 days
Feasibility of the CGM device will be evaluated by administering Likert-scale questionnaire results from parents, nurses, and research team. Questionnaires will assess acceptability of using the device by parents, nurses, and researchers; and ease of use, placement, and maintenance of the device.
7 days
Difference in number of needle sticks with CGM vs intermittent glucose monitoring
Time Frame: 1-7 days
The total number of estimated needle sticks with GCM will be compared to the total number of needle sticks from intermittent monitoring, using t-test.
1-7 days
Difference in number of episodes of hypoglycemia diagnosed with CGM vs intermittent glucose monitoring
Time Frame: 1-7 days
Total number of hypoglycemic episodes (blood glucose concentration <40 mg/dL at <4 hours, and <45 mg/dL thereafter) from GCM (episodes lasting >10 minutes) will be compared to the total number of hypoglycemic episodes from intermittent monitoring using t-test. Area under curve analysis will be completed to evaluate duration and severity of hypoglycemic episodes from CGM vs intermittent monitoring, as well as the response to treatment (feedings, dextrose gel, IV dextrose boluses, and dextrose infusions) and timing to normalization of glucose concentrations.
1-7 days

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Number of participants with adverse outcomes at the device site
Time Frame: 3 times per day for 1-7 days
Safety of CGM device will be evaluated by examinations for the presence of irritation, infection, cellulitis, bleeding, or other concerns at the device site.
3 times per day for 1-7 days

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Jeffrey R. Kaiser, MD, MA, Penn State Health Milton S Hershey Medical Center

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

August 9, 2021

Primary Completion (Estimated)

June 1, 2026

Study Completion (Estimated)

June 1, 2026

Study Registration Dates

First Submitted

May 9, 2020

First Submitted That Met QC Criteria

May 9, 2020

First Posted (Actual)

May 13, 2020

Study Record Updates

Last Update Posted (Estimated)

August 15, 2025

Last Update Submitted That Met QC Criteria

August 12, 2025

Last Verified

August 1, 2025

More Information

Terms related to this study

Other Study ID Numbers

  • 00014068

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

IPD Plan Description

Nothing will be shared

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

product manufactured in and exported from the U.S.

Yes

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Neonatal Hypoglycemia

Clinical Trials on Continuous Glucose Monitoring Device

Subscribe