Physician-modified Endovascular Graft for Repair of Complex Thoracoabdominal and Abdominal Aortic Aneurysms

August 25, 2025 updated by: Medstar Health Research Institute

Clinical Outcomes, Radiation Dosage, and Quality of Life in Patients Treated With Fenestrated Stent Grafts for Complex Thoracoabdominal and Abdominal Aortic Aneurysms, Thoracoabdominal Aortic Aneurysms Secondary to Aortic Dissections

The primary objective of this study is to assess the use of a physician-modified Cook Alpha Thoracic Endovascular Graft in the repair of complex aortic aneurysms and thoracoabdominal aortic aneurysms and aneurysms secondary to aortic dissections in high-risk patients having appropriate anatomy. The primary intent of the study is to assess the safety and preliminary effectiveness of the device. Additionally, the study will assess renal function, radiation exposure, and quality of life.

Study Overview

Detailed Description

This study is a prospective, single-center, non-randomized, single-arm study. Each enrolled subject will undergo periodic follow-up evaluations involving physical exams, computed tomography angiography (CTA) of chest, abdomen and pelvis, abdominal duplex ultrasound, creatinine measurement, quality of life questionnaire at specific, protocol-defined intervals for a period of five years following the physician-modified Cook Zenith® Alpha Endovascular Graft implant.

Study Type

Interventional

Enrollment (Estimated)

200

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • District of Columbia
      • Washington D.C., District of Columbia, United States, 20010
        • Medstar Washington Hospital Center

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  1. Age ≥ 18 years old
  2. Life expectancy > 2 year(s)
  3. Patient is considered to be at high risk of morbidity and mortality with open surgical repair
  4. A patient may be entered into the study if the patient has at least one of the following:

    • Juxtarenal, suprarenal or a thoracoabdominal aortic aneurysm with a diameter ≥ 5.5 cm or 2 times the normal aortic diameter
    • Aneurysm with a history of growth ≥ 0.5 cm per year
    • Saccular aneurysms deemed at significant risk for rupture based upon physician interpretation
    • Symptomatic juxtarenal, suprarenal or a thoracoabdominal aortic aneurysm
    • Thoracoabdominal aortic aneurysms secondary to aortic dissection meeting above criteria
  5. Patient is considered to be at high risk of morbidity and mortality with open surgical repair
  6. Iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit
  7. Nonaneurysmal aortic segment proximal to the aneurysm (neck) with a:

    • Minimum neck length of 20mm
    • Diameter in the range of 21-38mm
    • Angle less than 60° relative to the axis of the aneurysm
    • Angle less than 60° relative to the axis of the suprarenal aorta
  8. Minimum branch vessel diameter greater than 5 mm
  9. Iliac artery distal fixation site greater than 10mm in length and diameter in the range of 8-21mm.

Exclusion Criteria:

  1. Under the age of 18 years
  2. Can be treated in accordance with the instructions for use with a legally marketed endovascular prosthesis
  3. Is eligible for enrollment in a manufacturer-sponsored IDE at the investigational site
  4. Willing to participate in a sponsor-investigator IDE with access to a non-physician modified endovascular prostheses at the investigational site
  5. Willing to travel to an investigational site with access to a non-physician modified endovascular prosthesis
  6. Unwilling or unable to comply with the follow-up schedule
  7. Inability or refusal to give informed consent by patient or legal representative
  8. Patient is pregnant or breastfeeding
  9. Life expectancy < 2-years despite successful aneurysm exclusion
  10. Free rupture with hemodynamic instability
  11. Ongoing infection
  12. Diagnosis of, or suspected connective tissue disease
  13. Known sensitivities or allergies to the materials of construction of the devices
  14. Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed
  15. Uncorrectable coagulopathy
  16. Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment
  17. Patient has had a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned ≤ 30 days of the endovascular repair
  18. Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina)
  19. Systemic or local infection that may increase the risk of endovascular graft infection
  20. Leaking or free rupture of aneurysm associated with hemodynamic instability.
  21. Baseline creatinine greater than 3.0 mg/dL
  22. Known history of, or suspected connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome)

Anatomical exclusion criteria:

  1. Inadequate femoral or iliac access compatible with the required delivery systems, not amenable to open surgical or endovascular conduit placement
  2. Absence of a non-aneurysmal aortic segment for proximal seal zone with:

    • A diameter measured outer wall to outer wall of no greater than 38mm and no less than 21 mm;
    • Parallel aortic wall with <20% diameter change and without significant calcification and/or thrombus in the selected area of seal zone
  3. Visceral vessel anatomy not compatible with physician-modified Zenith® Alpha Endovascular Graft due to excessive occlusive disease or small size not amenable to stent graft placement
  4. Unsuitable distal iliac artery fixation site and anatomy:

    • Common iliac artery fixation site diameter measured outer wall to outer wall on a sectional image (CT) <8.0 mm with inability to perform open surgical conduit
    • Iliac artery diameter measured outer wall to outer wall on a sectional image (CT) >21 mm at distal fixation site, with inability to perform open internal iliac artery revascularization or iliac branch stent graft
    • Iliac artery distal fixation site <10 mm in length
    • Inability to preserve at least one hypogastric artery

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Endovascular repair
Endovascular repair of complex aortic aneurysms and thoracoabdominal aortic aneurysms including those secondary to aortic dissection using a physician-modified endovascular graft.
Cook Zenith® Alpha Thoracic Endovascular Graft will be modified to allow for the maintenance of blood flow into the visceral and renal branch vessels.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Freedom from Major Adverse Events (MAE) at 30 days
Time Frame: 30 days
Major Adverse Events include: Death, Bowel Ischemia, myocardial infarction, paraplegia/paraparesis, renal failure, respiratory failure, and stroke
30 days
Proportion of study subjects with treatment success at 1 year
Time Frame: 1 year

Treatment success is defined as a composite of technical success and freedom from the following:

  • Aneurysm enlargement [i.e., >5mm) as compared to a preoperative CT measure using orthogonal (i.e, perpendicular to the centerline) measurements]
  • Aneurysm rupture
  • Aneurysm-related mortality
  • Conversion to open repair
  • Secondary intervention for migration, Type I and III endoleaks, device integrity failure (e.g., fracture), and patency-related events (i.e., device component stenosis or occlusion and embolic events)
1 year
Technical success
Time Frame: 1 year

Technical success is defined as:

  • Successful delivery (i.e., ability to deliver the implant to the intended implantation site, without the need for unanticipated corrective intervention related to delivery) and deployment of the device at the intended location,
  • Patency of all endovascular graft and branch stent components
  • Absence of device deformations requiring unplanned placement of an additional device
  • Absence of inadvertent covering of aortic branch vessels
  • Successful withdrawal (i.e., successful withdrawal of the delivery system, without need for unanticipated corrective intervention related to withdrawal)
1 year

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Quality of Life measures
Time Frame: 30 days, 6 months; 1, 2, 3, 4 and 5 years
Questionnaire using SF - 36™ Health Survey
30 days, 6 months; 1, 2, 3, 4 and 5 years

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Javairiah Fatima, MD, Medstar Health Research Institute

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

September 20, 2021

Primary Completion (Estimated)

September 1, 2028

Study Completion (Estimated)

September 1, 2028

Study Registration Dates

First Submitted

August 21, 2020

First Submitted That Met QC Criteria

August 21, 2020

First Posted (Actual)

August 26, 2020

Study Record Updates

Last Update Posted (Estimated)

August 29, 2025

Last Update Submitted That Met QC Criteria

August 25, 2025

Last Verified

January 1, 2025

More Information

Terms related to this study

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Juxtarenal Aortic Aneurysm

Clinical Trials on Physician-Modified Cook Zenith Alpha Thoracic Endovascular Graft