Using Superimposition of Intra-Oral Scan and CBCT in Single Implant Restorations in Aesthetic Zone.

January 24, 2023 updated by: Dina Mohamed Aboulftouh Ahmed, Faculty of Dental Medicine for Girls

Patients' Satisfaction and Aesthetic Outcomes of Single Implant Restorations in Aesthetic Zone Using Superimposition of Intra-Oral Scan and CBCT.

This study will be performed to evaluate patients'satisfaction and aesthetic outcomes of single implant restorations in aesthetic zone by using superimposition of intra-oral scan and CBCT.

Study Overview

Detailed Description

The accurate transfer of an ideal implant position from virtual planning to the actual implant site is essential for protecting vital structures as well as optimizing esthetic and functional outcomes.With the introduction of 3D imaging and implant planning software, preoperative design for a "prosthesis-driven" implant position becomes a reality.

The initial stage is digital image acquisition, which can be from extra-oral means such as cone beam computed tomography (CBCT) and laboratory scanners, or intraoral means such as intraoral scanners.

Image fusion or superimposition of the STL data obtained from the optical scanning, with the DICOM data obtained from the CBCT, is performed by matching the common reference points prior to implant planning.

The superimposed images enable virtual implant planning, while taking the surrounding anatomic structures and future prosthetic needs into consideration.

To conduct the present study, the following will be used:

  1. DICOM file of CBCT for examination of single implant in aesthetic zone.
  2. STL file of optical scanning for examination of single implant in aesthetic zone.
  3. An implant planning software.
  4. One type of dental implant.

Study Type

Interventional

Enrollment (Anticipated)

14

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Cairo, Egypt
        • Al-Azhar University

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  1. At least 1 tooth having missed within 3-4 months or to be extracted in anterior zone, and the remaining teeth are adequate to support the surgical template.
  2. Sufficient bone tissue to insert an implant without any need for augmentation (the residual bone height ≥ 10 mm, the buccolingual width ≥ 7 mm, and the labial bone plate is complete without bone dehiscence and fenestration).
  3. Good treatment compliance.

Exclusion Criteria:

  1. Presence of uncontrolled systemic diseases, infection, or inflammation around the implant sites.
  2. Pregnancy or lactation.
  3. Poor oral hygiene habits.
  4. Psychiatric problems, alcohol, tobacco (>10 cigarettes per day) or drug abuse.
  5. Severe bruxism or clenching.
  6. Not able to complete the follow-up.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Double

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
No Intervention: Implant planning without using superimposition of intraoral scan and CBCT.
Patients will receive a pre-operative CBCT examination. Implants will be inserted using freehand drilling protocol. The implants will be placed using flapless technique with the reference of neighboring teeth and 3D radiographic information.
Active Comparator: Implant planning using superimposition of intraoral scan and CBCT.
Patients will receive a pre-operative CBCT examination and optical scan of the oral tissues by intra-oral scanner. Digital Imaging and Communications in Medicine (DICOM) file from the CBCT examination and the Standard Tessellation Language (STL) file from the optical scan will be imported and merged in implant planning software. The virtual implant planning will be performed. The surgical guide and prosthesis are designed according to the virtual plan.
These files will be imported in implant planning software,and virtual implant planning will be performed.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Pink Esthetic Score
Time Frame: 0-3 month
A total of seven variables (mesial papilla, distal papilla, level of soft-tissue margin, soft-tissue contour,alveolar process deficiency, soft-tissue color,and soft-tissue texture) assessing soft tissue around single implant supported restoration with a score of 0 to 2 (0 representing the poorest and 2 the best result) . The maximum score of 14 points reflects perfect implant esthetics with that of the contra lateral tooth.
0-3 month
Implant Crown Aesthetic Index
Time Frame: 0-3months
A total of nine variables ( Width ,Length ,Labial convexity ,Color/translucency,Surface,Labial margin ,Papillae, Contour of the labial surface,Color and surface) assessing implant crown and soft tissue esthetics using the score of 0=no deviation, 1= small deviation and 5=large deviation. The maximum score of 45 points reflects perfect implant esthetics with that of contra lateral and adjacent tooth.
0-3months
White Esthetic Score
Time Frame: 0-3 months
A total of five variables (tooth form,tooth volume/outline, color, surface texture and translucency) assessing implant crown esthetics using a score from 0 = worst to 2 = best result. The highest possible score of 0 reflects perfect implant esthetics with that of the contra-lateral tooth.
0-3 months
Peri-Implant and Crown Index (PICI)
Time Frame: 0-3months
A total of six variables (Papillae ,Zenith ,Root convexity o f the peri implant mucosa and Shape ,Color ,Characterization of the implant crown )assessing crown,mucosa and Overall crown and mucosa compared to contra lateral tooth using 100 mm visual analogue scale.
0-3months
Patient satisfaction level
Time Frame: 3months
using a subjective outcome questionnaire filled out by patient him/herself
3months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Study Director: Osama S Abdel Ghani, Professor & Head of Crowns and Bridges Department Faculty of Dental Medicine for Girls
  • Study Director: Roqaia M Alassar, Lecturer of Crowns and Bridges Faculty of Dental Medicine for Girls

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

September 7, 2021

Primary Completion (Actual)

October 7, 2022

Study Completion (Anticipated)

April 1, 2023

Study Registration Dates

First Submitted

September 8, 2021

First Submitted That Met QC Criteria

September 13, 2021

First Posted (Actual)

September 23, 2021

Study Record Updates

Last Update Posted (Estimate)

January 26, 2023

Last Update Submitted That Met QC Criteria

January 24, 2023

Last Verified

January 1, 2023

More Information

Terms related to this study

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Patient Satisfaction

Clinical Trials on superimposition of DICOM file from CBCT and STL file of Intraoral scanner

Subscribe