- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT05284903
Hearing Aid Performance Study for Different Spatial Configurations
Study Overview
Status
Conditions
Intervention / Treatment
- Other: Beamformer Benefit: Speech intelligibility and Listening effort
- Other: Speech Enhancer benefit: Speech intelligibility, Listening effort and Subjective Speech intelligibility
- Other: Hearing aid benefit: Speech intelligibility in noise (unaided vs aided condition)
- Other: Hearing aid benefit: Speech intelligibility in noise (aided condition)
Detailed Description
Hearing aids are designed to amplify and transmit sound to compensate for impaired hearing. The main objective of this medical device is to improve the perception of speech, which can be defined among many attributes by intelligibility or listening effort. Evaluating the performance of the hearing aid or different features reasonably assumes that the talker location should be in front and close of the hearing aid user. However, listening situations in daily life might show much more variability regarding the spatial configuration of the talker, listener and noise sources.
This investigation is designed to extend the evaluation of hearing aid features to different spatial configuration and also to evaluate the benefit of the investigational device. The investigational device is European conformity (CE) marked and will be used within its defined use and on the intended population. The investigation is divided into three independent parts:
- Beamformer (BF) benefit: the first part of the study will evaluate the effect of a wider beamformer on intelligibility and listening effort for a speech-in-noise condition when the talker is not in front of the listener in comparison to a narrower beamformer,
- Speech Enhancer benefit: the second part of the study will evaluate the effect of the Speech Enhancer algorithm on distant speech in quiet and when speech in quiet is coming from an adjacent room with different measures such as listening effort, objective and subjective speech intelligibility,
- Hearing aid benefit: the third part of the study will evaluate the benefit provided by amplification with a speech-in-noise test where the talker is in front and close to the hearing aid user
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Niedersachsen
-
Oldenburg, Niedersachsen, Germany, 26129
- Hörzentrum Oldenburg gGmbH
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Experienced (minimum use duration 6 months)
- Adult (minimum age: 18 years) hearing aid users,
- Written and spoken German,
- Ability to understand instruction,
- Ability to describe listening experiences,
- Ability to attend to the appointments,
- Healthy outer ear,
- Hearing loss within the fitting ranges of the investigational product,
- Informed consent as documented by signature.
Exclusion Criteria:
- Clinical contraindications deformity of the ear (closed ear canal or absence of pinna),
- Known hypersensitivity or allergy,
- Not willing to wear the hearing aid,
- Fluctuating hearing that could influence the results.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Randomized
- Interventional Model: Single Group Assignment
- Masking: Single
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Other: Experimental: Phonak device with activated feature
The clinical investigation is designed to evaluate clinical performances in terms of speech intelligibility and listening effort.
The expected benefit is based on clinical relevant differences.
This clinical investigation is divided in three parts including Beamformer benefit, Speech Enhancer benefit and Hearing aid benefit (this part will be performed aided).
|
Confirm the improvement in terms of speech intelligibility (measured by OLSA, Oldenburg Sentence Test) and the reduction in terms of listening effort (measured by ACALES) of the I-BF (investigational Beamformer) compared to the R-BF (reference Beamformer), when speech is not coming from the front.
Confirm the improvement in terms of speech intelligibility (measured by Oldenburg Sentence test) and the reduction in terms of listening effort (measured by ACALES) when the Speech Enhancer is on (SE ON) compared to Speech Enhancer is off (SE OFF) for distant speech or speech from adjacent room. Confirm the improvement in terms of subjective level to follow a conversation in quiet when SE ON compared to SE OFF for distant speech or speech from adjacent room. Measured by a subjective assessment.
Confirm the improvement in terms of speech intelligibility (measured by OLSA) in noise with the investigational device (aided condition) compared to the unaided condition.
Confirm the improvement in terms of speech intelligibility (measured by OLSA) with the Reference binaural beamformer compared to the fixed directional.
|
|
Other: Comparator: Phonak device with deactivated feature
The comparative testings should be used as reference.
The measures will be performed by the same participant group and the same three parts will be evaluated including Beamformer (BF) benefit, Speech Enhancer benefit and Hearing aid benefit.
The reference will be performed without these features or with different settings of these features.
In case of the Hearing aid benefit, the reference is an unaided fitting.
|
Confirm the improvement in terms of speech intelligibility (measured by OLSA, Oldenburg Sentence Test) and the reduction in terms of listening effort (measured by ACALES) of the I-BF (investigational Beamformer) compared to the R-BF (reference Beamformer), when speech is not coming from the front.
Confirm the improvement in terms of speech intelligibility (measured by Oldenburg Sentence test) and the reduction in terms of listening effort (measured by ACALES) when the Speech Enhancer is on (SE ON) compared to Speech Enhancer is off (SE OFF) for distant speech or speech from adjacent room. Confirm the improvement in terms of subjective level to follow a conversation in quiet when SE ON compared to SE OFF for distant speech or speech from adjacent room. Measured by a subjective assessment.
Confirm the improvement in terms of speech intelligibility (measured by OLSA) in noise with the investigational device (aided condition) compared to the unaided condition.
Confirm the improvement in terms of speech intelligibility (measured by OLSA) with the Reference binaural beamformer compared to the fixed directional.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Speech reception threshold (SRT) for Beamformer Benefit (Oldenburg Sentence Test)
Time Frame: At the test and retest appointment, maximum duration of the test/retest is 120 minutes
|
The measure of the speech reception threshold (SRT) is a procedure to evaluate the speech intelligibility in different listening conditions.
The SRT in noise is defined as the signal-to-noise ratio (SNR) needed to understand 50% of the presented sentences.
The SNR is adapted based on the intelligibility score of the previous sentence.
The SRT will be measured with the Oldenburg Sentence Test (OLSA), which is a standard speech intelligibility test in German.
The OLSA test uses nonsense sentences with equivalent difficulty.
|
At the test and retest appointment, maximum duration of the test/retest is 120 minutes
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Listening Effort for Beamformer Benefit (ACALES)
Time Frame: At the test and retest appointment, maximum duration of the test/retest is 120 minutes
|
The ACALES will be used to determine listening effort in different situations.
Speech stimuli (OLSA sentences) are either presented at different levels in a background noise with fixed level or at different distances from the listener in a quiet environment.
This creates different SNRs (speech levels at the position of the listener).
The listening effort is subjectively rated on a predefined 13-point categorical scale with varying difficulties (SNRs or talker distance), 1= "no effort", 7 = "moderate effort" to 13 = "extreme effort".
ACALES adaptively chooses the SNRs or talker distances for each presentation on the basis of previous ratings.
|
At the test and retest appointment, maximum duration of the test/retest is 120 minutes
|
|
Listening effort for SE benefit (ACALES)
Time Frame: At the test appointment, maximum duration of the test is 120 minutes
|
The ACALES will be used to determine listening effort in different situations.
The ACALES will be repeated for 3 distances and 2 conditions (SE Off vs On).
The outcome is a rating on a 13 points scale, as the difficulty is fixed by the distance now.
|
At the test appointment, maximum duration of the test is 120 minutes
|
|
Speech Intelligibility for SE benefit (Oldenburg Sentence Test)
Time Frame: At the test and retest appointment, maximum duration of the test/retest is 120 minutes
|
The measure of the speech perception in % is an alternative procedure to evaluate the speech intelligibility in different listening conditions.
The Speech perception is defined as % correct words out of a sentence list of 20 sentences.
Initially an individual presentation level is measured using adaptive procedure to determine the level necessary to understand 50% of all presented words.
Afterwards the correct word score can be obtained using this individual presentation level (reduced by 1 dB) by calculating the ratio of correct words by the number of total words.
|
At the test and retest appointment, maximum duration of the test/retest is 120 minutes
|
|
Subjective Perception, Subjective Assessment for SE benefit (Questionnaire)
Time Frame: At the test and retest appointment, maximum duration of the test/retest is 120 minutes
|
A subjective assessment will be used to determine the subjective perception. For this purpose, a novel is either read by the tester aloud (with soft voice) or presented by a loudspeaker in a reverberant room in three different distances (2m, 4m, 8m) and in an adjacent room with door left ajar. The subject rates his/her perception of the presented real and recorded speech using a questionnaire on the dimensions "loudness, listening effort and speech intelligibility". The subjects will rate the perception on the same scale (1- 100%) for both tested conditions (SE Off and SE On) with pencils with different colors to get either absolute and relative ratings. |
At the test and retest appointment, maximum duration of the test/retest is 120 minutes
|
|
Speech reception threshold (SRT) for Hearing Aid Benefit (Oldenburg Sentence Test)
Time Frame: At the test appointment, maximum duration of the test is 120 minutes
|
The measure of the speech reception threshold (SRT) is a procedure to evaluate the speech intelligibility in different listening conditions.
The SRT will be measured with the Oldenburg Sentence Test (OLSA), which is a standard speech intelligibility test in German.
SRTs are measured in 3 conditions: unaided, aided with fixed directional and aided with stereo zoom.
|
At the test appointment, maximum duration of the test is 120 minutes
|
Collaborators and Investigators
Sponsor
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- SRF-386
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Hearing Loss
-
MED-EL Elektromedizinische Geräte GesmbHCompletedHearing Loss | Hearing Loss, Sensorineural | Hearing Loss, Bilateral | Hearing Loss, Conductive | Hearing Loss, Unilateral | Hearing Loss, MixedAustria, Germany, United Kingdom
-
Oticon MedicalNot yet recruitingSensorineural Hearing Loss, Bilateral | Sensorineural Hearing Loss, Severe | Sensorineural Hearing Loss, Profound
-
Oticon MedicalCompletedEar Diseases | Hearing Loss, Conductive | Hearing Loss Mixed | Hearing Disability | Conductive Hearing Loss | Conductive Hearing Loss, Bilateral | Conductive Hearing Loss, UnilateralUnited Kingdom
-
Manchester University NHS Foundation TrustUniversity of ManchesterCompletedCochlear Hearing Loss | Sensorineural Hearing Loss, BilateralUnited Kingdom
-
Truway Health, Inc.Enrolling by invitationSensorineural Hearing Loss | Tinnitus | Sudden Hearing Loss | Acoustic Trauma | Inner Ear Injury | Noise-Induced Hearing Loss | Vestibular DysfunctionUnited States
-
University of California, San FranciscoPatient-Centered Outcomes Research InstituteRecruitingHearing Loss | Hearing Loss, Sensorineural | Hearing Loss, Bilateral | Hearing Loss, Conductive | Hearing Loss, Noise-Induced | Hearing Loss, Unilateral | Hearing Loss, Mixed | Hearing Disorders in ChildrenUnited States
-
Envoy Medical CorporationActive, not recruitingSensorineural Hearing Loss | Sensorineural Hearing Loss (Disorder) | Sensorineural Hearing Loss, Bilateral | Sensorineural Hearing Loss, Severe | Sensorineural Hearing Loss, Profound | Sensori-Neural DeafnessUnited States
-
Oticon MedicalCompletedConductive Hearing Loss | Conductive and Sensori-neural Hearing Loss in the Same Ear | Unilateral, Profound Sensori-neural Hearing LossUnited States
-
Frequency TherapeuticsCompletedHearing Loss, Sensorineural | Presbycusis | Noise Induced Hearing Loss | Sudden Hearing LossUnited States
-
Frequency TherapeuticsCompletedHearing Loss, Sensorineural | Noise Induced Hearing Loss | Sudden Hearing LossUnited States
Clinical Trials on Beamformer Benefit: Speech intelligibility and Listening effort
-
Luxottica Group S.p.A.University of Western Ontario, CanadaCompleted
-
Sonova AGCompletedHearing Loss, Bilateral | Hearing Loss, UnilateralGermany
-
Oticon MedicalCompletedSensorineural Hearing Loss | Cochlear Hearing LossFrance
-
University of NottinghamNational Institute for Health Research, United KingdomRecruiting
-
University Hospital, ToulouseCentre National de la Recherche Scientifique, FranceCompletedHearing Loss, UnilateralFrance
-
Assistance Publique - Hôpitaux de ParisURC Necker Cochin, FranceRecruitingCochlear Implants | Profound Hearing LossFrance
-
Assistance Publique - Hôpitaux de ParisRecruitingSensorineural Hearing LossFrance
-
Milton S. Hershey Medical CenterPenn State University; Congressionally Directed Medical Research ProgramsActive, not recruiting
-
Hospital de Clinicas de Porto AlegreUnknown
-
Oticon MedicalCompletedEar Diseases | Hearing Loss, Conductive | Hearing Loss Mixed | Hearing Disability | Conductive Hearing Loss | Conductive Hearing Loss, Bilateral | Conductive Hearing Loss, UnilateralUnited Kingdom