Accuracy of the Dexcom G7 Continuous Glucose Monitoring System Following Cardiac Surgery (DexcomG7)
February 20, 2026 updated by: The Cleveland Clinic
This is a prospective longitudinal study to study the agreement between a continuous glucose monitoring system (CGMS) versus current blood glucose monitoring.
Subjects in this study will have their blood glucose measured regularly every 1-3 hours with current methods in the Cardiovascular Intensive Care Unit (CVICU), and by Point of Care (POC) fingerstick glucose using the Accucheck Inform II on the regular floors, and the CGMS reading at the same time will be captured.
Subjects will have measurements taken throughout their stay in the CVICU and on the regular floors.
Agreement and correlation between systems, as well as errors, will be calculated.
Study Overview
Status
Completed
Conditions
Intervention / Treatment
Detailed Description
The Dexcom G7 will be placed either by an anesthesiologist or nurse anesthetist, or critical care physician, nurse or nurse manager upon arrival to CVICU, post cardiac surgery.
Standard of care:
Accuchek will be done per standard of care for post operative patients that are in ICU
Study Type
Interventional
Enrollment (Actual)
28
Phase
- Not Applicable
Contacts and Locations
This section provides the contact details for those conducting the study, and information on where this study is being conducted.
Study Locations
-
-
Ohio
-
Cleveland, Ohio, United States, 44195
- The Cleveland Clinic Foundation
-
-
Participation Criteria
Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
No
Description
Inclusion Criteria:
- Age 18 years old and above
- Planned cardiothoracic surgery
- Planned admission to Cleveland Clinic Main Campus building J5 or J6 or Q5 cardiovascular intensive care unit (CVICU) followed by transfer to the step down unit
- With or without known diabetes (as 75% of patients entering the CVICU have hyperglycemia requiring intravenous insulin infusion)
- If with known diagnosis of diabetes, diabetes can be type 1, type 2, or secondary (such as due to glucocorticoids or pancreatitis
Exclusion Criteria:
- Allergy to the material of the continuous glucose monitoring systems (CGMS) or the adhesive to be used
- Skin conditions precluding the use of the CGMS
- Pregnancy
- Other conditions that the investigators deem inappropriate for the study
- Patients receiving mechanical circulatory assist devices
Study Plan
This section provides details of the study plan, including how the study is designed and what the study is measuring.
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Other: Single Arm
All patients will receive the Dexcom G7 continuous glucose monitor (CGM)
|
Dexcom G7 used in blinded mode
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Compare accuracy of glucose readings obtained from Dexcom G7 compared to blood glucose obtained from arterial blood gas (ABG) or peripheral/central venous catheter or fingerstick point of care (POC) while patients are in the CVICU
Time Frame: 1 - 10 days
|
Compare accuracy of glucose readings obtained from Dexcom G7 Compared to blood glucose obtained from arterial blood gas (ABG) or peripheral/central venous catheter or fingerstick POC while patients are in the CVICU
|
1 - 10 days
|
|
Compare accuracy of glucose readings obtained from Dexcom G7 compared to blood glucose obtained from fingerstick POC glucose when patients are on the regular floors
Time Frame: 1 - 10 days
|
Compare accuracy of glucose readings obtained from Dexcom G7 compared to blood glucose obtained from fingerstick POC glucose when patients are on the regular floors
|
1 - 10 days
|
Collaborators and Investigators
This is where you will find people and organizations involved with this study.
Sponsor
Collaborators
Investigators
- Principal Investigator: Lansang Cecilia, MD, The Cleveland Clinic
Study record dates
These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.
Study Major Dates
Study Start (Actual)
November 2, 2024
Primary Completion (Actual)
October 1, 2025
Study Completion (Actual)
December 31, 2025
Study Registration Dates
First Submitted
March 23, 2024
First Submitted That Met QC Criteria
March 29, 2024
First Posted (Actual)
April 1, 2024
Study Record Updates
Last Update Posted (Actual)
February 23, 2026
Last Update Submitted That Met QC Criteria
February 20, 2026
Last Verified
February 1, 2026
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 24-157
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
NO
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
No
Studies a U.S. FDA-regulated device product
Yes
product manufactured in and exported from the U.S.
No
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Continuous Glucose Monitoring
-
Peking Union Medical College HospitalNot yet recruitingContinuous Glucose Monitoring
-
Chinese Medical AssociationRecruitingContinuous Glucose MonitoringChina
-
Sinocare Meditech Inc.Integrated Medical DevelopmentCompletedContinuous Glucose MonitoringUnited States
-
WaveForm Technologies Inc.UnknownContinuous Glucose Monitoring
-
WaveForm Technologies Inc.Completed
-
West China HospitalCompletedFeasibility | Safety | Continuous Glucose Monitoring System | AccuracyChina
-
Nutrition 21, Inc.The Center for Applied Health Sciences, LLCRecruitingPost-menopause | Peri-menopausal Women | Whole Body Protein Metabolism | Glucose Monitoring, ContinuousUnited States
-
Zealand University HospitalRecruitingAnesthesia | Surgical Procedure, Unspecified | Hyperglycemia Stress | Continuous Glucose Monitoring | Hyperglycemia Steroid-inducedDenmark
-
Bispebjerg HospitalActive, not recruitingRemote Monitoring | Vital Signs Monitoring | Hospital at Home | Continuous MonitoringDenmark
-
Assistance Publique - Hôpitaux de ParisCompletedUnits Continuous Monitoring (USC)France
Clinical Trials on Continuous glucose monitor (CGM) Dexcom G7 used in blinded mode
-
Woman'sDexCom, Inc.TerminatedPostpartum Gestational Diabetes MellitusUnited States
-
Woman'sDexCom, Inc.CompletedGestational Diabetes Mellitus in PregnancyUnited States
-
Wake Forest University Health SciencesNot yet recruitingGlucose Metabolism Disorders (Including Diabetes Mellitus)United States
-
University of Massachusetts, WorcesterCompleted
-
Sykehuset i Vestfold HFRecruitingGastric Bypass Surgery | Hypoglycemia Non-DiabeticNorway
-
Vanderbilt University Medical CenterRecruitingHyperglycemia | Type 2 Diabetes Mellitus (T2DM) | Type 1 Diabetes Mellitus (T1DM)United States
-
University of California, San FranciscoDexCom, Inc.Active, not recruitingInsulin Resistance | Dysglycemia | PCOS (Polycystic Ovary Syndrome) of Bilateral OvariesUnited States
-
University Hospital PadovaUniversity of PadovaCompletedHypoglycemia | Glycogen Storage Disease | Congenital Hyperinsulinism (CHI)Italy
-
Mayo ClinicSuspendedDiabetes MellitusUnited States
-
University of MinnesotaCompletedHyperglycemia | Very Low Birth Weight Infant | Very Preterm Maturity of InfantUnited States