Fabrication and Insertion of Michigan Splints by Dental Students

April 17, 2024 updated by: Juliana Marotti Großhausen

Herstellung Und Eingliederung Von Michigan-Schienen Durch Zahnmedizinstudierende: Eine Qualitative Und Quantitative Studie

The aim of this study is to investigate the potential effects of different jaw relation determination (KRB) techniques on the fabrication of Michigan splints, in particular by comparing conventional methods with a wax plate and the use of an anterior jig. All materials and methods for the fabrication of the Michigan splint are already part of the curriculum of the Clinic for Dental Prosthodontics for first-year Master-students. Therefore, we intend to conduct a retrospective study (for the 2023 cohort) and a prospective analysis of the data (for the 2024 and 2025 cohorts). Questionnaires, models and intraoral scans will be used to evaluate the efficacy and precision of the different KRB methods as well as the fabrication process of the Michigan splint.

Study Overview

Status

Enrolling by invitation

Detailed Description

Since its development in the 1960s as a modification of the Sved-biteplane constructed in Scandinavia, the Michigan splint has gained worldwide recognition and can now be described as the gold standard of treatment with stabilization splints for myoarthopathies. The use of stabilization splints - as confirmed in an S3 guideline published by the Association of the Scientific Medical Societies in Germany (AWMF) in 2019 - is classified as a recommendable and, if necessary, reversible therapeutic measure for the treatment of bruxism. As part of a systematic review, additional causes were identified in addition to the seven already known central risk factors for bruxism. In addition to factors such as emotional stress and anxiety disorders, further psychological disorders were added as part of the literature review. Against this background of a predominantly psychologically determined aetiopathogenesis, acceptance of the splint by the patient could represent an important component of successful treatment for bruxism, for example in terms of increased patient compliance. Sufficient evidence-based studies that specifically investigate a possible connection between the type of fabrication of the Michigan splint and its acceptance by the patient are still lacking. The Michigan splint is a proven method for the treatment of patients diagnosed with bruxism. In the conventional method, the KRB of the Michigan splint is fabricated using the wax technique, which can lead to inaccuracies in registration due to its material properties. With the advancement of digital technology, the use of intraoral scanners is becoming more common in dental practices. In these cases, KRB can be performed with a jig using a material with higher precision than wax. Furthermore, the KRB can be scanned with the JIG without interfering with wax. To date, no studies have been conducted comparing the quality of the Michigan splint with these two KRB methods. For the fabrication of the jig, the condyles must serve as support points, which is why it is not possible to perform in vitro studies with the JIG.

The primary objective of this study is to descriptively analyze the quality of Michigan splints fabricated by dental students. The parameters examined relate to the fit, extension and function of the splint. Likewise, the common KRB methods (wax plate and anterior jig) are to be compared in order to identify any discrepancies and thus consequences in the fabrication of the splint. The data obtained from the scans will be analyzed and points compared in order to compare possible differences between the various bite registration methods. The secondary aim of this study is to analyze and possibly improve the fabrication process of Michigan splints in the context of dental student education.

Study Type

Observational

Enrollment (Estimated)

73

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

Yes

Sampling Method

Non-Probability Sample

Study Population

Dental Students

Description

Inclusion Criteria:

  • Dental students in the first year of their Master's degree
  • 18 years and older, gender independent
  • Ability to give informed consent, documented by signature

Exclusion Criteria:

  • Inability or contraindications (e.g. dental pain, dental mobility, generalized periodontitis, removable denture wearers, acute infection) to undergo the procedure under study
  • Inability to follow the procedures of the study, e.g. due to language problems, depression or mental disorders
  • Students who do not consent to the analysis of the data

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
Wax registration
The jaw relation for the Michigan-splint will be performed with wax.
The quality of the Michigan-splint will be analyzed according to different interventions (wax or jig jaw relation) and a questionnaire that quantify the occlusal contacts of the splint.
The quality of the Michigan-splint will be analyzed according to different interventions (wax or jig jaw relation) and a questionnaire that quantify the occlusal contacts of the splint.
JIG registration
The jaw relation for the Michigan-splint will be performed with JIG.
The quality of the Michigan-splint will be analyzed according to different interventions (wax or jig jaw relation) and a questionnaire that quantify the occlusal contacts of the splint.
The quality of the Michigan-splint will be analyzed according to different interventions (wax or jig jaw relation) and a questionnaire that quantify the occlusal contacts of the splint.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Wax vs JIG Registration
Time Frame: From enrollment to the end of treatment at 6 weeks
The deviation (in micrometers) between the wax and JIG registration will be measured with the software CloudCompare.
From enrollment to the end of treatment at 6 weeks

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Questionnaire
Time Frame: From enrollment to the end of treatment at 6 weeks
In order to analyze the quality of the splints, a questionnaire will be implemented where points will be given (For example: 0=unsatisfactory, 1=corrections needed, 2=satisfactory) for the each topic and answer.
From enrollment to the end of treatment at 6 weeks

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

March 8, 2024

Primary Completion (Estimated)

May 1, 2024

Study Completion (Estimated)

December 1, 2025

Study Registration Dates

First Submitted

March 18, 2024

First Submitted That Met QC Criteria

April 17, 2024

First Posted (Actual)

April 22, 2024

Study Record Updates

Last Update Posted (Actual)

April 22, 2024

Last Update Submitted That Met QC Criteria

April 17, 2024

Last Verified

April 1, 2024

More Information

Terms related to this study

Additional Relevant MeSH Terms

Other Study ID Numbers

  • 2024-00148 (Registry Identifier: EKNZ)

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

UNDECIDED

IPD Plan Description

I will share the IPD upon request. All data, study protocol and informed consent of participants can be shared.

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Bruxism

Clinical Trials on Jaw relation

Subscribe