Comparison Between CAD/CAM and Conventional Mandibular Fixed Retainers.

Comparison Between CAD/CAM and Conventional Mandibular Fixed Retainers: a Randomized Controlled Trial

The devices compared in this study are 'retainers', i.e. fixed orthodontic retainers applied to the lingual surface of the central and lateral incisors and lower canines bilaterally. Their function is to maintain dental alignment once fixed orthodontic therapy has ended. In particular, the CAD/CAM device Keeppy patented by the company Leone SpA (Via Ponte a Quaracchi 50, Sesto Fiorentino, Florence) will be compared with the standard retainer made from a steel braided wire (Ortho FlexTech, Reliance Orthodontic Products Inc., 1540 West Thorndale Ave, Itasca, Illinois, USA).

This is a single-center, national, controlled, superiority, randomized, crossover, open-label study.

The aim of this study is to evaluate whether the CAD/CAM retainer results in fewer failures (fractures or detachments) over a period of 6 months and 2 years compared to the standard retainer. In addition, the aim of the study is to evaluate whether the Keeppy device results in the maintenance of better periodontal health as judged by the use of plaque and bleeding indices on the surfaces of the lower six anterior teeth compared to the standard retainer. Other objectives consist of the patient's assessment of pain, difficulty in speaking and esthetic satisfaction and the stability of the lower anterior tooth sector.

Study Overview

Study Type

Interventional

Enrollment (Estimated)

54

Phase

  • Not Applicable

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Child
  • Adult

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • Patients who have completed fixed orthodontic therapy between the ages of 13 and 20 years;
  • Patients whose parents will sign the informed consent

Exclusion Criteria:

  • Presence of dental anomalies in number (excess or deficiency) in the lower anterior teeth
  • Patients with metal allergies.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: CAD/CAM mandibular fixed retainer
Keeppy is a Class IIa custom-made medical device manufactured by Digital Service Leone s.r.l. - via Pratese 160/b, Florence, Italy. The Keeppy is an individualized fixed retainer, made of a Nickel-free Chrome Cobalt alloy, produced with a CAD-CAM procedure starting from a digital impression made with an intraoral optical scanner (3 Shape), which allows a perfect adaptation to the lingual surfaces of the 6 lower anterior teeth on which it is bonded. The device is characterized by the presence of applicators that can be placed temporarily on the buccal surface of the canines, which facilitate the clinician in the precise application of the device and which are removed as soon as the bonding phase of the retainer is complete. Bonding is performed using classic composite resins following a preparation phase of the lingual surface of the tooth consisting of the application of etchant (37% orthophosphoric acid) for 30 seconds and adhesive (primer-bonding).
Other Names:
  • Keeppy
Active Comparator: Conventional mandibular fixed retainer
The standard control device, which is among the most commonly used in routine clinical practice, consists of a steel braided wire. The device selected for the Class IIa investigation is the Ortho Flex Tech manufactured by Reliance Orthodontic Products, Inc. 1540 West Thorndale Ave. Itasca, IL 60143 USA. The Ortho Flex Tech steel braided wire is manually shaped by the clinician and cut with a wire cutter so that it has the proper length to extend over the 6 dental elements. Once the correct length has been defined, it is then held in place on the lingual surface of the teeth by the use of 2 interdental wires passing doubly through the interdental area (between the lateral incisor and canine on one side and the other). This allows the device to be bonded using composite resin after etching the lingual surfaces of the lower anterior teeth.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Retainer failure at 6-month and 2-year follow-ups
Time Frame: At 6 months and at 2 years
The primary endpoint is retainer failures at 6-month and 2-year follow-ups. Failure is defined as any complication requiring a retainer repair, in particular total or partial detachment and total or partial fracture.
At 6 months and at 2 years

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Assessment of the plaque and gingival bleeding index at the central and lateral incisors and lower canines.
Time Frame: At baseline, at 6 months and at 2 years
Assessment of the plaque and gingival bleeding index at the central and lateral incisors and lower canines.
At baseline, at 6 months and at 2 years
Pain reported by patients
Time Frame: At baseline, at one month, at 6 months and at 2 years
Pain measured through Visual Analogue Scale (VAS) with minimum value of 0 and maximum value of 10. Higher scores mean worse pain.
At baseline, at one month, at 6 months and at 2 years
Difficulty in speaking reported by patients
Time Frame: At baseline, at one month, at 6 months and at 2 years
Difficulty in speaking measured through Visual Analogue Scale (VAS) with minimum value of 0 and maximum value of 10. Higher scores mean worse difficulty in speaking.
At baseline, at one month, at 6 months and at 2 years
Aesthetic satisfaction reported by patients
Time Frame: At baseline, at one month, at 6 months and at 2 years
Aesthetic satisfaction measured through Visual Analogue Scale (VAS) with minimum value of 0 and maximum value of 10. Higher scores mean higher aesthetic satisfaction.
At baseline, at one month, at 6 months and at 2 years
Stability of the alignment of the lower anterior teeth
Time Frame: At 6 months and at 2 years
Stability of the alignment of the lower anterior teeth will be assessed with Little's irregularity index and the intercanine diameter measured on the virtual impression of the patient's teeth.
At 6 months and at 2 years

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

September 1, 2024

Primary Completion (Estimated)

February 1, 2026

Study Completion (Estimated)

September 1, 2027

Study Registration Dates

First Submitted

July 10, 2024

First Submitted That Met QC Criteria

July 29, 2024

First Posted (Actual)

July 31, 2024

Study Record Updates

Last Update Posted (Actual)

July 31, 2024

Last Update Submitted That Met QC Criteria

July 29, 2024

Last Verified

July 1, 2024

More Information

Terms related to this study

Other Study ID Numbers

  • LF15

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Orthodontic Retainers

Clinical Trials on CAD/CAM mandibular fixed retainer

Subscribe