- ICH GCP
- US Clinical Trials Registry
- Klinisk forsøg NCT06784063
Visuel ydeevne med Clareon® Vivity® intraokulære linser (IOL'er)
10. juli 2026 opdateret af: Alcon Research
Evaluering af indvirkningen af resterende astigmatisme på den visuelle ydeevne med Clareon Vivity
Formålet med denne undersøgelse er at generere kliniske data for at kvantificere indvirkningen af resterende astigmatisme på den overordnede visuelle ydeevne under afstands-, mellem- og nærvisning hos patienter implanteret med Clareon Vivity IOL'er.
Studieoversigt
Status
Afsluttet
Betingelser
Intervention / Behandling
Detaljeret beskrivelse
Denne enkeltbesøgsundersøgelse er designet til at hjælpe med at forstå, hvordan synet påvirkes, hvis øjet stadig har astigmatisme efter kataraktoperation.
Deltagerne vil være personer, der allerede har gennemgået en operation for grå stær og modtaget en Clareon Vivity IOL i begge øjne mindst 4 måneder før studietilmeldingen.
Under studiebesøget vil forsøgslinser (glaslinser, der bruges under en øjenundersøgelse) blive brugt til midlertidigt at skabe effekten af astigmatisme på øjet.
Undersøgelsestype
Interventionel
Tilmelding (Faktiske)
40
Fase
- Ikke anvendelig
Kontakter og lokationer
Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.
Studiesteder
-
-
Michigan
-
Bloomfield Hills, Michigan, Forenede Stater, 48302
- Grosinger, Spigelman & Grey Eye Surgeons, P.C
-
-
Texas
-
Dallas, Texas, Forenede Stater, 75243
- Key-Whitman Eye Center
-
Sugar Land, Texas, Forenede Stater, 77478
- Berkeley Eye Center
-
-
Deltagelseskriterier
Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.
Berettigelseskriterier
Aldre berettiget til at studere
- Voksen
- Ældre voksen
Tager imod sunde frivillige
Ingen
Beskrivelse
Inklusionskriterier:
- Kunne forstå og underskrive en Institution Review Board-godkendt informeret samtykkeformular;
- Villig og i stand til at deltage i alle planlagte studiebesøg som krævet af protokollen;
- Implanteret med undersøgelses-IOL'er i begge øjne mindst 4 måneder før undersøgelsesdeltagelse;
- BCDVA på 0 logMAR eller bedre i hvert øje.
Ekskluderingskriterier:
- Resterende astigmatisme større end eller lig med 1,00 D;
- Klinisk signifikante okulære tilstande som specificeret i protokollen;
- Anamnese med andre øjenoperationer end limbal afslappende snit
- Andre protokol-specificerede eksklusionskriterier kan være gældende.
Studieplan
Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: N/A
- Interventionel model: Enkelt gruppeopgave
- Maskning: Ingen (Åben etiket)
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Eksperimentel: Clareon Vivity/Vivity Toric
Tidligere implantation i begge øjne med Clareon Vivity/Vivity Toric Extended Vision IOL'er, med tidligere implantation defineret som mindst 4 måneder før studiedeltagelse.
|
Intraokulær linse med udvidet syn implanteret i øjets kapselpose under operation for grå stær.
IOL'er er beregnet til langtidsbrug i løbet af kataraktpatientens levetid.
Andre navne:
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Mean Difference in Monocular Best Corrected Distance Visual Acuity (BCDVA) (4 Meters) Before and After Inducing 1.0 Diopter (D) Astigmatism - WTR
Tidsramme: Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
BCDVA was assessed with best refractive correction in place at a distance of 4 meters (m) using Early Treatment Diabetic Retinopathy Study (ETDRS) letter charts.
Trial lenses were used to induce 1.0 diopter (D) of astigmatism with-the-rule (WTR), defined as -0.50/+1.00
D at approximately 180 degrees on the optical axis.
VA was measured in the first implanted eye in logarithm minimum angle of resolution (logMAR), with a lower logMAR value indicating better visual acuity.
The change in VA before and after inducing astigmatism is reported, with a positive value representing a decline in VA.
No hypothesis testing was prespecified for this co-primary endpoint.
|
Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
|
Mean Difference in Monocular Distance Corrected Intermediate Visual Acuity (DCIVA) (66 Centimeters) Before and After Inducing 1.0 D Astigmatism - WTR
Tidsramme: Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
DCIVA was assessed with distance correction in place (plus or minus power) at a distance of 66 centimeters (cm) from the spectacle plane using ETDRS letter charts.
Trial lenses were used to induce 1.0 D of astigmatism with-the-rule (WTR), defined as -0.50/+1.00
D at approximately 180 degrees on the optical axis.
VA was measured in the first implanted eye in logarithm minimum angle of resolution (logMAR), with a lower logMAR value indicating better visual acuity.
The change in VA before and after inducing astigmatism is reported, with a positive value representing a decline in VA.
No hypothesis testing was prespecified for this co-primary endpoint.
|
Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
|
Mean Difference in Monocular Distance Corrected Near Visual Acuity (DCNVA) (40 cm) Before and After Inducing 1.0 D Astigmatism - WTR
Tidsramme: Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
DCNVA was assessed with distance correction in place (plus or minus power) at a distance of 40 cm from the spectacle plane using ETDRS letter charts.
Trial lenses were used to induce 1.0 D of astigmatism WTR, defined as -0.50/+1.00
D at approximately 180 degrees on the optical axis.VA was measured in the first implanted eye in logarithm minimum angle of resolution (logMAR), with a lower logMAR value indicating better visual acuity.
The change in VA before and after inducing astigmatism is reported, with a positive value representing a decline in VA.
No hypothesis testing was prespecified for this co-primary endpoint.
|
Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
|
Mean Difference in Monocular Best Corrected Distance Visual Acuity (BCDVA) (4 Meters) Before and After Inducing 1.0 Diopter (D) Astigmatism - ATR
Tidsramme: Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
BCDVA was assessed with best refractive correction in place at a distance of 4 m using ETDRS letter charts.
Trial lenses were used to induce 1.0 D of astigmatism against the rule (ATR), defined as -0.50/+1.00
D at approximately 90 degrees on the optical axis.
VA was measured in the first implanted eye in logarithm minimum angle of resolution (logMAR), with a lower logMAR value indicating better visual acuity.
The change in VA before and after inducing astigmatism is reported, with a positive value representing a decline in VA.
No hypothesis testing was prespecified for this co-primary endpoint.
|
Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
|
Mean Difference in Monocular Distance Corrected Intermediate Visual Acuity (DCIVA) (66 Centimeters) Before and After Inducing 1.0 D Astigmatism.- ATR
Tidsramme: Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
DCIVA was assessed with distance correction in place (plus or minus power) at a distance of 66 cm from the spectacle plane using ETDRS letter charts.
Trial lenses were used to induce 1.0 D of astigmatism ATR, defined as -0.50/+1.00
D at approximately 90 degrees on the optical axis.
VA was measured in the first implanted eye in logarithm minimum angle of resolution (logMAR), with a lower logMAR value indicating better visual acuity.
The change in VA before and after inducing astigmatism is reported, with a positive value representing a decline in VA.
No hypothesis testing was prespecified for this co-primary endpoint.
|
Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
|
Mean Difference in Monocular Distance Corrected Near Visual Acuity (DCNVA) (40 cm) Before and After Inducing 1.0 D Astigmatism - ATR
Tidsramme: Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
DCNVA was assessed with distance correction in place (plus or minus power) at a distance of 40 cm from the spectacle plane using ETDRS letter charts.
Trial lenses were used to induce 1.0 D of astigmatism ATR, defined as -0.50/+1.00
D at approximately 90 degrees on the optical axis.
VA was measured in the first implanted eye in logarithm minimum angle of resolution (logMAR), with a lower logMAR value indicating better visual acuity.
The change in VA before and after inducing astigmatism is reported, with a positive value representing a decline in VA.
No hypothesis testing was prespecified for this co-primary endpoint.
|
Day 0 before induced astigmatism; Day 0 after induced astigmatism
|
Samarbejdspartnere og efterforskere
Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.
Sponsor
Efterforskere
- Studieleder: Clinical Trial Lead, Surgical CRD, Alcon Research, LLC
Publikationer og nyttige links
Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.
Hjælpsomme links
Datoer for undersøgelser
Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.
Studer store datoer
Studiestart (Faktiske)
10. april 2025
Primær færdiggørelse (Faktiske)
13. juni 2025
Studieafslutning (Faktiske)
13. juni 2025
Datoer for studieregistrering
Først indsendt
15. januar 2025
Først indsendt, der opfyldte QC-kriterier
15. januar 2025
Først opslået (Faktiske)
20. januar 2025
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
13. juli 2026
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
10. juli 2026
Sidst verificeret
1. juli 2026
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- ILE632-C003
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
INGEN
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Ingen
Studerer et amerikansk FDA-reguleret enhedsprodukt
Ja
produkt fremstillet i og eksporteret fra U.S.A.
Ingen
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .
Kliniske forsøg med Clareon Vivity Extended Vision IOL
-
Alcon ResearchTrukket tilbagePresbyopi | Aphakia | Resterende brydningscylinderForenede Stater
-
Alcon ResearchTrukket tilbage
-
Vance Thompson VisionAfsluttetGrøn stær | Grå stær | PresbyopiForenede Stater
-
Alcon ResearchAfsluttetAphakiaAustralien, New Zealand
-
Alcon ResearchRekruttering
-
Valley Laser Eye CentreSengiAfsluttet
-
The Eye AssociatesIkke rekrutterer endnuGrå stærForenede Stater
-
Milton S. Hershey Medical CenterAfsluttet
-
Newsom Eye & Laser CenterAfsluttet