- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT06891794
Verwendung von Gebärmutterhalskappen und Menstruationsscheiben zur Anwendung von topischem Anästhetikum vor der IUP -Insertion
Verwendung von Gebärmutterhalskappen und Menstruationsscheiben zur Anwendung von topischem Anästhetikum vor Intrauteriner Geräte (IUP)
This prospective, open label, double arm, feasibility group study will recruit participants planning to undergo office intrauterine device (IUD) placement without sedation or anxiolysis at the Center for Women's Health. Participants will self-administer a topical anesthetic using a contraceptive cervical cap or menstrual disc.
Twenty-four nulliparous women will be recruited to receive one of two administration methods immediately prior to IUD placement (12 subjects in each arm): 1) menstrual disc filled with 5g eutectic mixture of local anesthetics (EMLA) cream or 2) cervical cap filled with 5g EMLA cream.
Studienübersicht
Status
Bedingungen
Intervention / Behandlung
Detaillierte Beschreibung
Nulliparous patients undergoing IUD insertion will administer EMLA cream by menstrual disc or cervical cap prior to insertion. The medical provider will ensure proper placement of the cap or disc and perform a bi-manual exam to assess the patient's uterine position. A seven minute timer will be set, the cap/disc will be removed, and the provider will proceed with the IUD insertion according to manufacturer technique.
Visual Analog Scale (VAS) scores will be used throughout the procedure to assess participant pain throughout insertion. Participants and providers will report on pain, side effects, and procedure complications immediately after the procedure.
Studientyp
Einschreibung (Tatsächlich)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
Oregon
-
Portland, Oregon, Vereinigte Staaten, 97239
- Oregon Health & Science University
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Scheduled for IUD placement at the Center for Women's Health in Complex Family Planning clinic
- Able to review and sign study consents in English
- Generally healthy
Exclusion Criteria:
- History of any prior births, miscarriages, or abortions after 16 weeks' gestation
- Currently pregnant, known or suspected
- Current stringless IUD in place
- Participants premedicated with misoprostol
- History of chronic pelvic pain which patients take daily medication for
- History of endometriosis, fibroids, adenomyosis, prior cervical procedures (such as Loop Electrosurgical Excision Procedure (LEEP) or cold knife cone)
- Any contraindications to IUD placement (per current labeling including pregnancy, fibroids that distort the uterine cavity, exam consistent with pelvic inflammatory disease, allergy to any component of the levonorgestrel intrauterine system (LNG-IUS), etc.)
- Known allergy to eutectic mixture of local anesthetics (EMLA) or lidocaine cream, silicone, menstrual disc, or cervical cap
- Any contraindication to EMLA or lidocaine cream, menstrual disc, or cervical cap
- Previous IUD placement or failed attempt of an IUD placement
- Weight < 54.4kg (120 lbs)
- Plan for use of oral anxiolysis, moderate/deep sedation, or narcotics for procedure
- Patient requesting or patient use in the past 24 hours of oral anxiolysis, moderate/deep sedation, or narcotics
- Any planned concomitant procedures, such as dilation and curettage (D&C), endometrial biopsy, colposcopy, hysteroscopy, etc.
- Illicit drug use
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Verhütung
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Experimental: Menstrual disc
Participants will be provided with a menstrual disc filled with 5mg of 2.5% prilocaine-2.5% lidocaine cream and manufacturer instructions for placement. Study personnel will leave the room, and participants will undress and attempt to place the disc. The provider will return to the room, make sure the disc is correctly placed, and set a seven minute timer. After the seven minute timer, participants will self-remove the disc or the clinician will remove it and place the intrauterine device (IUD) according to manufacturer technique. |
Eutectic mixture of local anesthetics (EMLA) cream self-administered using a menstrual disc
Andere Namen:
|
|
Experimental: Cervical cap
Participants will be provided with a cervical cap filled with 5mg of 2.5% prilocaine-2.5% lidocaine cream and manufacturer instructions for placement. Study personnel will leave the room, and participants will undress and attempt to place the cap. The provider will return to the room, make sure the cap is correctly placed, and set a seven minute timer. After the seven minute timer, participants will self-remove the cap or the clinician will remove it and place the intrauterine device (IUD) according to manufacturer technique. |
Eutectic mixture of local anesthetics (EMLA) cream self-administered using a menstrual disc
Andere Namen:
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Successful Placement
Zeitfenster: Immediately after IUD placement procedure
|
The number of participants able to correctly place the cap or disc as instructed, assessed by provider |
Immediately after IUD placement procedure
|
|
Satisfaction with pain control
Zeitfenster: Immediately after IUD placement procedure
|
Participant-reported satisfaction with pain control for IUD placement using EMLA cream measured the Patient Acceptable Symptom State (PASS) methodology. |
Immediately after IUD placement procedure
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Ease of cap/disc placement
Zeitfenster: Immediately after IUD placement procedure
|
Participant-reported ease of placement of menstrual cap or disc. Response options will be "very easy", "somewhat easy", "neutral", "somewhat difficult", and "very difficult". |
Immediately after IUD placement procedure
|
|
Protocol deviations
Zeitfenster: Immediately after IUD placement procedure
|
Provider-reported deviations from the standard protocol including need for additional analgesia, oral pain medication, oral anxiolytic medication, need for cervical dilation, rescheduling with sedation per patient preference, or other. |
Immediately after IUD placement procedure
|
|
Ease of IUD placement
Zeitfenster: Immediately after IUD placement procedure
|
Provider-reported ease of IUD placement with response options "usual", "difficult", or "very difficult" |
Immediately after IUD placement procedure
|
|
Procedure complications
Zeitfenster: Immediately after IUD placement procedure
|
Provider-reported complications of IUD placement procedure including vagal reaction, perforation, placement failure, allergic reaction, or other. |
Immediately after IUD placement procedure
|
|
Typical menstrual pain
Zeitfenster: On the day of IUD placement procedure prior to cap/disc placement and IUD placement
|
Patient-reported 11-point Numerical Rating Scale (NRS) of their menstrual pain where 0 represents no pain and 10 represents the worst possible pain. |
On the day of IUD placement procedure prior to cap/disc placement and IUD placement
|
|
Pain during IUD placement procedure
Zeitfenster: Measured throughout IUD placement procedure immediately before the procedure, during placement of disc/cap, during speculum placement, during tenaculum placement, during sounding, during IUD placement, and 5 minutes after completion
|
Patient-reported pain using a 100 millimeter Visual Analog Scale (VAS) throughout IUD placement procedure. Participants will mark their level of pain along a 100mm line, where one end (0) represents no pain and the other represents the worst possible pain (100). The distance from the "no pain" end to the participant's mark is measured to provide a numeric representation of pain |
Measured throughout IUD placement procedure immediately before the procedure, during placement of disc/cap, during speculum placement, during tenaculum placement, during sounding, during IUD placement, and 5 minutes after completion
|
|
Acceptability of pain mangement
Zeitfenster: one day post-procedure
|
Patient-reported acceptability of pain management measured by a 5-point Likert scale question. Participants will be asked "How would you rate your satisfaction with the pain control during your IUD placement?". Response options range from very satisfied (1) to very dissatisfied (5). |
one day post-procedure
|
Andere Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Reasons for non-participation
Zeitfenster: During screening/enrollment at the time when an eligible participant declines participation
|
For eligible prospective participants who were approached but declined participation, they will be asked the reason why they chose not to participate. This will be an open-ended response where the study staff member performing the screening will record the reason for declining participation. |
During screening/enrollment at the time when an eligible participant declines participation
|
Mitarbeiter und Ermittler
Ermittler
- Hauptermittler: Julia Tasset, Oregon Health and Science University
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- STUDY00028118
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .