- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT04289480
Seguridad y eficacia del dispositivo ENTERPRISE 2 en el tratamiento endovascular de aneurismas intracraneales (EMPOWER)
ENTERPRISE 2 Vascular Reconstruction Device and Delivery System Registry: un estudio observacional multicéntrico, prospectivo y de un solo brazo para evaluar la seguridad y la eficacia con el dispositivo para facilitar la embolización endovascular de aneurismas intracraneales
The study is designed to evaluate the safety and effectiveness of ENTERPRISE 2 vascular reconstruction device and delivery system (hereinafter referred to as ENTERPRISE 2) to facilitate endovascular coil embolization of intracranial aneurysms.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
This is a prospective, multicenter, single-arm observational study, in which enrolled patients will be implanted with the ENTERPRISE 2 for evaluation of safety and effectiveness of ENTERPRISE 2 in real-world applications.
The study population will consist of 164 patients with ruptured or unruptured intracranial aneurysms and a parent vessel diameter of ≥2.5 mm and ≤4 mm. All patients will be implanted with the study device.
The enrolled patients will be followed at 30 days, 180 days, 1 year, 2 years, 3 years, 4 years and 5 years post procedure.
The primary endpoint is the incidence of aneurysm recanalization (at 180 days) evaluated through digital subtraction angiography (DSA). Secondary effectiveness endpoints include incidence of aneurysm recanalization (at 1 year), successful stent/coil placement rate (immediately post procedure), aneurysm occlusion (immediately post procedure, at 180 days and 1 year), incidence of retreatment (at 30 and 180 days, and 1, 2, 3, 4 and 5 years). Safety evaluation include: incidence of disabling stroke or neurological death (at 180 days and 1 year), incidence of in-stent thrombosis (at 180 days and 1 year), and incidence of in-stent stenosis (at 180 days and 1 year). Exploratory endpoints include stent wall apposition performance (intra-procedure), first-time deployment success rate (intra-procedure) and duration of stent deployment (intra-procedure).
Tipo de estudio
Inscripción (Actual)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Beijing Municipality
-
Beijing, Beijing Municipality, Porcelana, 100070
- Beijing Tiantan Hospital, Capital Medical University
-
Beijing, Beijing Municipality, Porcelana, 100029
- Beijing Anzhen Hospital, Capital Medical University
-
-
Guangdong
-
Guangzhou, Guangdong, Porcelana
- Zhujiang Hospital of Southern Medical University
-
-
Henan
-
Zhengzhou, Henan, Porcelana, 450052
- The first affiliated hospital of Zhengzhou university
-
-
Hubei
-
Wuhan, Hubei, Porcelana, 430022
- Union Hospital, Tongji Medical College, Huazhong University of Science & Technology
-
-
Jiangsu
-
Nanjing, Jiangsu, Porcelana, 210008
- Nanjing Drum Tower Hospital
-
-
Jiangxi
-
Nanchang, Jiangxi, Porcelana, 330006
- The first affiliated hospital of Nanchang university
-
-
Liaoning
-
Shenyang, Liaoning, Porcelana, 110004
- Shengjing Hospital of China Medical University
-
-
Shanghai Municipality
-
Shanghai, Shanghai Municipality, Porcelana
- Huashan Hospital Shanghai Medical college, Fudan University
-
-
Zhejiang
-
Hangzhou, Zhejiang, Porcelana, 310007
- Zhejiang Hospital
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
This study will be conducted in patients with unruptured or ruptured intracranial aneurysm with a parent vessel diameter of ≥2.5 mm and ≤4 mm.
Descripción
Inclusion Criteria:
- Patient (or his/her legal representative) understands the nature of the procedure and provides voluntary written informed consent for the use of his/her peri-procedural and follow-up data;
- Aged between 18 years and 80 years of age the time of consent;
- Patient has been diagnosed with ruptured (Hunt-Hess Grade I-III) or unruptured intracranial aneurysm and requires the endovascular treatment;
- Parent vessel with a diameter of ≥2.5 mm and ≤4 mm;
- Patient is willing to return to the investigational site for the post-procedure follow-up evaluations.
Exclusion Criteria:
- Severe co-morbidity associated with a life-expectancy of less than twelve months as determined by the investigator;
- Poor clinical condition with modified Rankin Scale (mRS) score ≥4;
- Having prior or potential severe allergic reaction to contrast medium;
- Known allergies to any of the device components, including Enterprise 2 and PROWLER® SELECT™ Plus Infusion Catheter;
- Angiogram demonstrating that the aneurysm is not appropriate for endovascular treatment (i.e. severe intracranial vessel tortuosity, stenosis, intracranial vasospasm not responsive to medical therapy);
- Arteriovenous malformation (AVM) in the territory of the target aneurysm;
- Unsuitable for the antithrombotic and/or anticoagulant therapies;
- Implantation of an intracranial stent associated with aneurysm or symptom distribution within 12 weeks prior to signature of Informed Consent Form;
- Implantation of a carotid stent associated with aneurysm or symptom distribution within 12 weeks prior to signature of Informed Consent Form;
- Evidence of active infection;
- Pregnant or lactating women;
- Having participated in clinical studies of other investigational drugs or devices within 30 days prior to signature of Informed Consent Form, excluding epidemiological studies of observational nature or natural history or not involving intervention;
- Pre-planned staged procedure of target aneurysms.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Modelos observacionales: COHORT
- Perspectivas temporales: PROSPECTIVE
Cohortes e Intervenciones
Grupo / Cohorte |
Intervención / Tratamiento |
|---|---|
|
ENTERPRISE 2 group
The study population enrolled for this clinical study is "aneurysm patients who need stent-assisted coiling treatment", using ENTERPRISE 2 device. |
The ENTERPRISE 2 Vascular Reconstruction Device is intended for use with occlusive devices in the treatment of intracranial aneurysms. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Incidence of aneurysm recanalization
Periodo de tiempo: at 180 days post procedure
|
Incidence of aneurysm recanalization (at 180 days) = number of target aneurysm recanalization (at 180 days) ÷ total number of target aneurysms receiving follow-up × 100%. The results of aneurysm angiography at 180-day follow-up will be obtained through DSA, and the post-procedure immediate aneurysm recanalization shown in angiograms will be graded as per the Raymond-Roy Classification Scale. The Raymond-Roy Classification at each follow-up time point increased by ≥ one class relative to that immediately after the procedure is defined as recanalization (e.g., Class I immediately after the procedure, Class II at 180-day follow-up). |
at 180 days post procedure
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Incidence of aneurysm recanalization
Periodo de tiempo: at 1 year post procedure
|
Incidence of aneurysm recanalization (at 1 year) = number of target aneurysm recanalization (at 1 year) ÷ total number of target aneurysms receiving follow-up × 100%. The results of aneurysm angiography at 1 year follow-ups will be obtained through DSA or MRA or CTA. |
at 1 year post procedure
|
|
Successful stent/coil placement rate
Periodo de tiempo: immediately post procedure
|
Successful stent/coil placement rate = number of target aneurysms with successful stent/coil placement ÷ total number of target aneurysms× 100%. Successful stent/coil placement is defined as successful stent deployment and successful delivery and placement of the coil at the target aneurysm assessed immediately post procedure through angiography. |
immediately post procedure
|
|
Aneurysm occlusion
Periodo de tiempo: immediately post procedure, at 180 days and at 1 year post procedure
|
Aneurysm occlusion rate = number of target aneurysms with Raymond-Roy Class I or II aneurysm occlusion÷ total number of target aneurysms× 100%. The aneurysm occlusion will be assessed by classifying the post-procedure immediate aneurysm occlusion shown in angiograms based on the Raymond-Roy Classification. |
immediately post procedure, at 180 days and at 1 year post procedure
|
|
Incidence of retreatment
Periodo de tiempo: at 30 days, 180 days, 1 year, 2 years, 3 years, 4 years and 5 years post procedure
|
Incidence of retreatment = number of target aneurysms receiving retreatment during the follow-up ÷ total number of target aneurysms receiving follow-up ×100%. Retreatment refers to any intervention to the target aneurysm after completing first stent-assisted coil embolization for the target aneurysm. |
at 30 days, 180 days, 1 year, 2 years, 3 years, 4 years and 5 years post procedure
|
Otras medidas de resultado
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Incidence of disabling stroke or neurological death
Periodo de tiempo: at 180 days, at 1 year post procedure
|
Incidence of disabling stroke or neurological death = number of patients with disabling stroke or neurological death ÷ total number of patients receiving follow-up × 100%. Stroke is defined as rapidly developing clinical signs of focal (or global) disturbance of cerebral function lasting more than 24 hours with no apparent cause other than of vascular origin, including ischemic stroke or hemorrhagic stroke (i.e., intraparenchymal hemorrhage (IPH), SAH, subdural hemorrhage (SDH), epidural hemorrhage (EDH)). Disabling stroke is defined as mRS score ≥ 3 assessed at a minimum of 90 days (+/- 30 days) post-stroke event. Neurological death, also called brain death, refers to irreversible loss of the capacity for consciousness combined with the irreversible loss of all brainstem functions, including the capacity to breathe. |
at 180 days, at 1 year post procedure
|
|
Incidence of in-stent thrombosis
Periodo de tiempo: at 180 days, at 1 year post procedure
|
Incidence of in-stent thrombosis = number of target aneurysms with parent vessel (in-stent) thrombosis during follow-up ÷ total number of target aneurysms receiving follow-up ×100%. |
at 180 days, at 1 year post procedure
|
|
Incidence of in-stent stenosis
Periodo de tiempo: at 180 days, at 1 year post procedure
|
Incidence of in-stent stenosis = number of target aneurysms with parent vessel (in-stent) stenosis during follow-up ÷ total number of target aneurysms receiving follow-up ×100%. Mild, moderate, and severe in-stent stenosis is clinically defined as a stenosis of <33%, 33-67%, and ≥67%, respectively, comparing with non-stented parent vessel [43, 44]. In this study, moderate and severe in-stent stenoses (with a stenosis of ≥33%) of the parent vessel are defined as in-stent stenosis. |
at 180 days, at 1 year post procedure
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Xinjian Yang, Professor, Beijing Tiantan Hospital
- Investigador principal: Shiqing Mu, Professor, Beijing Tiantan Hospital
- Investigador principal: Qingrong Zhang, Professor, The Affiliated Nanjing Drum Tower Hospital of Nanjing University Medical School
- Investigador principal: Yuxiang Gu, Professor, Huashan Hospital Shanghai Medical college, Fudan University
- Investigador principal: Chuanzhi Duan, Professor, Southern Medical University, China
- Investigador principal: Shu Wan, Professor, Zhejiang Hospital
- Investigador principal: Bo Yu, Professor, Shengjing Hospital
- Investigador principal: Yang Wang, Professor, The First Affiliated Hospital of Nanchang University
- Investigador principal: Sheng Guan, Professor, The First Affiliated Hospital of Zhengzhou University
- Investigador principal: Wohua Zhao, Professor, Union Hospital, Tongji Medical College, Huazhong University of Science & Technology
- Investigador principal: Xinjian Yang, Professor, Beijing Anzhen Hospital
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- CNV_2018_02
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Descripción del plan IPD
Johnson & Johnson Medical Device Companies have an agreement with the Yale Open Data Access (YODA) Project to serve as the independent review panel for evaluation of requests for clinical study reports and participant level data from investigators and physicians for scientific research that will advance medical knowledge and public health. Requests for access to the study data can be submitted through the YODA Project site at http://yoda.yale.edu.
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .