Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Una exploración de investigación (Me-4FDG PET/CT) para la detección del transporte de sodio y glucosa para el diagnóstico temprano del cáncer de pulmón

5 de noviembre de 2026 actualizado por: Jonsson Comprehensive Cancer Center

Tomografía por emisión de positrones Detección del transporte de sodio y glucosa para el diagnóstico precoz del cáncer de pulmón

The phase I/II trial assess the safety and efficacy of a new positron emission tomography (PET) test for early diagnosis of lung cancer. This study uses PET and Me-4FDG new glucose tracer (alpha-methyl-4-deoxy-4-[(18)F]fluoro-D-glucopyranoside) designed specifically to determine glucose update into cells in the body. PET is a non-invasive imaging method used to detect cancer in patient. Me4FDG is a radioactive glucose tracer used in PET to locate cells in the body taking up glucose by SGLT2. SLGT2 is a sodium glucose transport protein that accumulates glucose in some cells, e.g. kidney cells and tumors. This study may help researcher determine how effective PET with ME4FDG tracer works in detecting lung cancer.

Descripción general del estudio

Descripción detallada

PRIMARY OBJECTIVE:

I. Assess the safety and efficacy of alpha-methyl-4-deoxy-4-[(18)F]fluoro-D-glucopyranoside (Me-4FDG) for early diagnosis of lung cancer.

SECONDARY OBJECTIVE:

I. Evaluate the correlation of Me-4FDG positivity with histopathological features of the disease (tumor grade, expression of sodium-glucose cotransporter-2 inhibitors.(SGLT2).

OUTLINE:

Patients receive Me-4FDG tracer intravenously (IV) and then undergo PET/CT over 15 minutes.

After completion of study , patients are followed up at 7 days.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

60

Fase

  • Fase 2
  • Fase 1

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • California
      • Los Angeles, California, Estados Unidos, 90095
        • Yesenia Calzada

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • Age > 18 years
  • Lung nodule >= 1 cm visualized by CT imaging
  • CANCER ARM: Pathologically confirmed lung adenocarcinoma. For patients who are surgical candidates, the pathologic report on the surgical specimen will confirm the diagnosis. For patients who are not surgical candidates, the enrollment will be contingent upon a pathologic diagnosis of lung cancer obtained by needle biopsy
  • BENIGN ARM: Lung nodules considered to be clinically benign, according to the Guidelines for Management of Incidental Pulmonary Nodules from the Fleischner Society. Will consider "benign" the nodules with a lung-RADS score of 1-3

Exclusion Criteria:

  • Pregnancy
  • Diagnosis of diabetes
  • Current treatment with SGLT2 inhibitors or metformin

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Diagnóstico
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Diagnostic (Me-4FDG PET/CT)

Patients receive Me-4FDG tracer IV and then undergo PET/CT over 15 minutes.

Correlative studies

Undergo PET/CT

Otros nombres:
  • Imágenes médicas, tomografía por emisión de positrones
  • MASCOTA
  • Escaneo de mascotas
  • Tomografía por emisión de positrones
  • Tomografía de emisión de positrones
  • Imágenes espectroscópicas de resonancia magnética de protones

Undergo PET/CT

Otros nombres:
  • Connecticut
  • GATO
  • Análisis de gato
  • Tomografía Axial Computarizada
  • Tomografía axial computarizada
  • Tomografía computarizada
  • tomografía

Given IV

Otros nombres:
  • a-metil-4[18F]-4-desoxi-D-glucopiranósido
  • Alfa-metil-4-[F-18]-fluoro-4-desoxi-d-glucopiranósido
  • Me-4(18F)DG
  • Me-4FDG
  • Me4FDG
  • 4-DESOXI-4-FLUORO-.ALFA.-D-GLUCOPIRANOSIDO DE METILO. F-18

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Sensitivity of Alpha-methyl-4-deoxy-4-[(18)F]fluoro-D-glucopyranoside (Me-4FDG) positron-emission tomography (PET) scans
Periodo de tiempo: within one month of surgery or biopsy

Will be determined by calculating the standardized uptake value (SUV) in the lesions and the contrast to noise ratio (CNR) relative to an area of normal lung surrounding the lesion, and evaluated by assessing the percentage of patients with a pathologic diagnosis of lung cancer that results positive at Me-4FDG PET scans.

within one month of surgery or biopsy
Specificity of Me-4FDG for lung cancer
Periodo de tiempo: within one week of experimental PET/CT scan

Will be estimated by the percentage of Me-4FDG negativity in lung nodules that have been determined radiologically and/or clinically to be benign with a lung-RAD (Lung Imaging Reporting and Data System), score 1-3.

within one week of experimental PET/CT scan
Optimal combination of sensitivity and specificity
Periodo de tiempo: within one week of experimental PET/CT scan

Will combine SUV and CNR cut-points that yield the optimal combination of sensitivity (positivity within the adenocarcinoma group) and specificity (negativity with the benign group). Optimality will be based on the cut-points that maximize the Youden index (sum of the sensitivity plus specificity). Based on the combined cut point, will construct 95% confidence intervals for the sensitivity and specificity.

within one week of experimental PET/CT scan
Incidence of adverse events of Me-4FDG
Periodo de tiempo: From baseline to one week after Me-4FDG administration

Will tabulate the number of adverse events (AEs) and the severity of adverse events (SAEs) for the overall population as well as within subjects.

From baseline to one week after Me-4FDG administration
Efficacy of Me-4FDG in diagnosing lung cancer
Periodo de tiempo: within one week of the experimental PET/CT scan

Will be evaluated by measuring the percentage of test positivity in patients with a pathological diagnosis of lung cancer.

within one week of the experimental PET/CT scan

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Correlation of Me-4FDG positivity with histopathological features (tumor grade)
Periodo de tiempo: within one month of surgery or biopsy

Ordinal logistic regression will be used to assess the correlation between Me-4FDG uptake and tumor grade.

within one month of surgery or biopsy
Correlation of Me-4FDG positivity with histopathological features (expression of SGLT2)
Periodo de tiempo: within two months of surgery or biopsy

Will be evaluated experimentally with validated specific antibodies.

within two months of surgery or biopsy

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Investigadores

  • Investigador principal: Claudio Scafoglio, MD, PhD, UCLA / Jonsson Comprehensive Cancer Center

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

19 de enero de 2023

Finalización primaria (Estimado)

1 de octubre de 2027

Finalización del estudio (Estimado)

1 de octubre de 2028

Fechas de registro del estudio

Enviado por primera vez

12 de septiembre de 2022

Primero enviado que cumplió con los criterios de control de calidad

23 de septiembre de 2022

Publicado por primera vez (Actual)

28 de septiembre de 2022

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

9 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

5 de noviembre de 2026

Última verificación

1 de noviembre de 2026

Más información

Términos relacionados con este estudio

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

Sí

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

producto fabricado y exportado desde los EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir