Rendimiento de imágenes PET/CT de RefleXion en pacientes con diversas neoplasias malignas
Un estudio prospectivo piloto del rendimiento de imagenología del subsistema RefleXion [18F]-FDG PET-CT en pacientes con diversas neoplasias malignas
This clinical trial examines RefleXion Medical Radiotherapy System (RMRS) imaging to the standard of care (SOC) fludeoxyglucose F-18 ([18F]-FDG)- positron emission tomography (PET)-computed tomography (CT) imaging in patients with various cancers (malignancies). PET is an established imaging technique that utilizes small amounts of radioactivity attached to very minimal amounts of tracer, in the case of this research, [18F]-FDG. Because some cancers take up [18F]-FDG, cancer cells can be seen with PET. CT utilizes x-rays that traverse body from the outside. CT images provide an exact outline of organs and potential inflammatory tissue where it occurs in patient's body. The RefleXion system is designed to facilitate delivery of biology-guided radiotherapy (BgRT). The RMRS uses PET emissions to guide radiotherapy delivery in real-time and has been studied for use with FDG (which is an agent used in standard PET-CT scans that targets glucose). Information gathered from this study may help researchers to improve PET-CT imaging on the RefleXion system. This information will be used in the future to improve planning and delivery of radiotherapy that will target (in real time) the signal released from the [18F]-FDG-PET-CT tracer. Comparing the imaging from the standard of care [18F]-FDG-PET-CT with the [18F]-FDG imaging from RMRS may help improve the quality of the imaging captured and determine if imaging can be done on the RMRS at the same time as planning for radiation therapy, which would reduce the number of scans needed to plan for radiation for cancer.
Descripción general del estudio
Estado
Descripción detallada
PRIMARY OBJECTIVE:
I. To assess imaging performance of the [18F]-FDG PET-CT subsystem on the X1 RMRS to detect lesions (primary and metastatic) in patients with various types of malignancies.
SECONDARY OBJECTIVE:
I. To determine the feasibility of generating a BgRT plan using X1 RMRS-acquired [18F]-FDG PET data derived from the imaging-only session at the studied dose level.
OUTLINE:
Patients receive [18F]-FDG injection and undergo SOC [18F]-FDG PET-CT on study. Patients with at least one PET avid lesion then undergo X1 RMRS PET-CT imaging-only session on study.
Tipo de estudio
Inscripción (Estimado)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
California
-
Duarte, California, Estados Unidos, 91010
- City of Hope Medical Center
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Documented informed consent of the participant and/or legally authorized representative
- Age: >= 21 years
- Patients with malignancies (abdominal/pelvic/thoracic/head and neck/breast tumors) undergoing SOC [18F]-FDG PET-CT for diagnostic and/or radiotherapy planning purposes
- Patients should be scheduled for [18F]-FDG PET-CT prior to study entry
Exclusion Criteria:
- Known psychiatric or substance abuse disorder that would interfere with conduct of the study
- Patient weight exceeding the weight limit (450 pounds) outlined per X1 RMRS specifications sheet
- Lung parenchymal and bone tumors will be excluded as their imaging characteristics were evaluated in a previous study
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Viabilidad del dispositivo
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: Device ([18F]-FDG PET-CT, X1 RMRS PET-CT)
Patients receive [18F]-FDG injection and undergo SOC [18F]-FDG PET-CT on study. Patients with at least one PET avid lesion then undergo X1 RMRS PET-CT imaging-only session on study. |
Undergo [18F]-FDG PET-CT
Otros nombres:
Given via injection
Otros nombres:
Undergo X1 RMRS PET-CT Undergo [18F]-FDG PET-CT
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Imaging performance of X1 RefleXion Medical Radiotherapy System (RMRS) positron emission tomography (PET)-computed tomography (CT) with the Imaging performance of the diagnostic fludeoxyglucose F-18 ([18F]-FDG) PET-CT
Periodo de tiempo: Up to 72 hours
|
One key metric will be the percent of patients with lesions identified on standard of care (SOC) PET-CT that are not identified on X1 (false negatives if considering SOC the true standard). For the SOC [18F]-FDG PET-CT, the maximum standard uptake value (SUV) and the greatest dimension in centimeters will be recorded for each PET avid malignant lesion identified by the nuclear medicine radiologist. The patient's radiation oncologist will interpret the X1 PET scan for the same metrics. Graphical presentations will be provided to compare SOC positive lesions and X1 positive lesions, and SOC positive lesions and X1 negative lesions with regards to lesion size, lesion location (lymph nodes, soft tissue, visceral organ) and SUV uptake. Descriptive statistics will be utilized to quantify results. Mean, standard deviation, interquartile range (IQR), and range will be reported for each continuous variable. Frequency and percentage will be reported for categorical variables. |
Up to 72 hours
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Percent of cases where X1 RMRS PET data can be used to generate an acceptable biology-guided radiotherapy (BgRT) plan
Periodo de tiempo: Up to 72 hours
|
The true positive lesions identified on the X1 PET images will be identified and used for BgRT planning. Simulated planning using the RefleXion treatment planning software will be performed, and the radiation dose to organs at risk calculated. Principal investigator will determine whether this plan is acceptable or not. The percent of cases in which RefleXion [18F]-FDG PET data led to an acceptable plan will be recorded (descriptive statistics). Descriptive statistics will be utilized to quantify results. Mean, standard deviation, IQR, and range will be reported for each continuous variable. Frequency and percentage will be reported for categorical variables. |
Up to 72 hours
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Jeffrey Y Wong, City of Hope Medical Center
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
- Técnicas y procedimientos de diagnóstico
- Diagnóstico
- Carbohidratos
- Tomografía
- Imágenes de diagnóstico
- Desoxiglucosa
- Azúcares desoxi
- Interpretación de imágenes, asistida por computadora
- Mejora de la imagen
- Fotografía
- Tomografía, computada con emisiones
- Imágenes de radionúclidos
- Técnicas de diagnóstico, radioisótopo
- Fluorodesoxiglucosa F18
- Tomografía a emisión de positrones
Otros números de identificación del estudio
- 22668
- P30CA033572 (Subvención/contrato del NIH de EE. UU.)
- 22668 (Otro identificador: City of Hope Comprehensive Cancer Center)
- NCI-2023-01994 (Identificador de registro: CTRP (Clinical Trial Reporting Program))
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .