RefleXion PET/CT billeddannelsesydelse hos patienter med forskellige maligniteter
En prospektiv pilotundersøgelse af RefleXion [18F]- FDG PET-CT-undersystemets billeddannelsesydelse hos patienter med forskellige maligniteter
This clinical trial examines RefleXion Medical Radiotherapy System (RMRS) imaging to the standard of care (SOC) fludeoxyglucose F-18 ([18F]-FDG)- positron emission tomography (PET)-computed tomography (CT) imaging in patients with various cancers (malignancies). PET is an established imaging technique that utilizes small amounts of radioactivity attached to very minimal amounts of tracer, in the case of this research, [18F]-FDG. Because some cancers take up [18F]-FDG, cancer cells can be seen with PET. CT utilizes x-rays that traverse body from the outside. CT images provide an exact outline of organs and potential inflammatory tissue where it occurs in patient's body. The RefleXion system is designed to facilitate delivery of biology-guided radiotherapy (BgRT). The RMRS uses PET emissions to guide radiotherapy delivery in real-time and has been studied for use with FDG (which is an agent used in standard PET-CT scans that targets glucose). Information gathered from this study may help researchers to improve PET-CT imaging on the RefleXion system. This information will be used in the future to improve planning and delivery of radiotherapy that will target (in real time) the signal released from the [18F]-FDG-PET-CT tracer. Comparing the imaging from the standard of care [18F]-FDG-PET-CT with the [18F]-FDG imaging from RMRS may help improve the quality of the imaging captured and determine if imaging can be done on the RMRS at the same time as planning for radiation therapy, which would reduce the number of scans needed to plan for radiation for cancer.
Studieoversigt
Status
Detaljeret beskrivelse
PRIMARY OBJECTIVE:
I. To assess imaging performance of the [18F]-FDG PET-CT subsystem on the X1 RMRS to detect lesions (primary and metastatic) in patients with various types of malignancies.
SECONDARY OBJECTIVE:
I. To determine the feasibility of generating a BgRT plan using X1 RMRS-acquired [18F]-FDG PET data derived from the imaging-only session at the studied dose level.
OUTLINE:
Patients receive [18F]-FDG injection and undergo SOC [18F]-FDG PET-CT on study. Patients with at least one PET avid lesion then undergo X1 RMRS PET-CT imaging-only session on study.
Undersøgelsestype
Tilmelding (Anslået)
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
California
-
Duarte, California, Forenede Stater, 91010
- City of Hope Medical Center
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- Documented informed consent of the participant and/or legally authorized representative
- Age: >= 21 years
- Patients with malignancies (abdominal/pelvic/thoracic/head and neck/breast tumors) undergoing SOC [18F]-FDG PET-CT for diagnostic and/or radiotherapy planning purposes
- Patients should be scheduled for [18F]-FDG PET-CT prior to study entry
Exclusion Criteria:
- Known psychiatric or substance abuse disorder that would interfere with conduct of the study
- Patient weight exceeding the weight limit (450 pounds) outlined per X1 RMRS specifications sheet
- Lung parenchymal and bone tumors will be excluded as their imaging characteristics were evaluated in a previous study
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Enhedens gennemførlighed
- Tildeling: N/A
- Interventionel model: Enkelt gruppeopgave
- Maskning: Ingen (Åben etiket)
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Eksperimentel: Device ([18F]-FDG PET-CT, X1 RMRS PET-CT)
Patients receive [18F]-FDG injection and undergo SOC [18F]-FDG PET-CT on study. Patients with at least one PET avid lesion then undergo X1 RMRS PET-CT imaging-only session on study. |
Undergo [18F]-FDG PET-CT
Andre navne:
Given via injection
Andre navne:
Undergo X1 RMRS PET-CT Undergo [18F]-FDG PET-CT
Andre navne:
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Imaging performance of X1 RefleXion Medical Radiotherapy System (RMRS) positron emission tomography (PET)-computed tomography (CT) with the Imaging performance of the diagnostic fludeoxyglucose F-18 ([18F]-FDG) PET-CT
Tidsramme: Up to 72 hours
|
One key metric will be the percent of patients with lesions identified on standard of care (SOC) PET-CT that are not identified on X1 (false negatives if considering SOC the true standard). For the SOC [18F]-FDG PET-CT, the maximum standard uptake value (SUV) and the greatest dimension in centimeters will be recorded for each PET avid malignant lesion identified by the nuclear medicine radiologist. The patient's radiation oncologist will interpret the X1 PET scan for the same metrics. Graphical presentations will be provided to compare SOC positive lesions and X1 positive lesions, and SOC positive lesions and X1 negative lesions with regards to lesion size, lesion location (lymph nodes, soft tissue, visceral organ) and SUV uptake. Descriptive statistics will be utilized to quantify results. Mean, standard deviation, interquartile range (IQR), and range will be reported for each continuous variable. Frequency and percentage will be reported for categorical variables. |
Up to 72 hours
|
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Percent of cases where X1 RMRS PET data can be used to generate an acceptable biology-guided radiotherapy (BgRT) plan
Tidsramme: Up to 72 hours
|
The true positive lesions identified on the X1 PET images will be identified and used for BgRT planning. Simulated planning using the RefleXion treatment planning software will be performed, and the radiation dose to organs at risk calculated. Principal investigator will determine whether this plan is acceptable or not. The percent of cases in which RefleXion [18F]-FDG PET data led to an acceptable plan will be recorded (descriptive statistics). Descriptive statistics will be utilized to quantify results. Mean, standard deviation, IQR, and range will be reported for each continuous variable. Frequency and percentage will be reported for categorical variables. |
Up to 72 hours
|
Samarbejdspartnere og efterforskere
Sponsor
Samarbejdspartnere
Efterforskere
- Ledende efterforsker: Jeffrey Y Wong, City of Hope Medical Center
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Primær færdiggørelse (Anslået)
Studieafslutning (Anslået)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
- Diagnostiske teknikker og procedurer
- Diagnose
- Kulhydrater
- Tomografi
- Diagnostisk billeddannelse
- Deoxyglucose
- Deoxy sukker
- Billedtolkning, computerassisteret
- Billedforbedring
- Fotografering
- Tomografi, emission-kompettet
- Radionuclide Imaging
- Diagnostiske teknikker, radioisotop
- Fluorodeoxyglucose F18
- Positron-emissionstomografi
Andre undersøgelses-id-numre
- 22668
- P30CA033572 (U.S. NIH-bevilling/kontrakt)
- 22668 (Anden identifikator: City of Hope Comprehensive Cancer Center)
- NCI-2023-01994 (Registry Identifier: CTRP (Clinical Trial Reporting Program))
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .