- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT05844306
RefleXion PET/CT-Bildgebungsleistung bei Patienten mit verschiedenen malignen Erkrankungen
Eine prospektive Pilotstudie zur Bildgebungsleistung des RefleXion [18F]-FDG-PET-CT-Subsystems bei Patienten mit verschiedenen malignen Erkrankungen
This clinical trial examines RefleXion Medical Radiotherapy System (RMRS) imaging to the standard of care (SOC) fludeoxyglucose F-18 ([18F]-FDG)- positron emission tomography (PET)-computed tomography (CT) imaging in patients with various cancers (malignancies). PET is an established imaging technique that utilizes small amounts of radioactivity attached to very minimal amounts of tracer, in the case of this research, [18F]-FDG. Because some cancers take up [18F]-FDG, cancer cells can be seen with PET. CT utilizes x-rays that traverse body from the outside. CT images provide an exact outline of organs and potential inflammatory tissue where it occurs in patient's body. The RefleXion system is designed to facilitate delivery of biology-guided radiotherapy (BgRT). The RMRS uses PET emissions to guide radiotherapy delivery in real-time and has been studied for use with FDG (which is an agent used in standard PET-CT scans that targets glucose). Information gathered from this study may help researchers to improve PET-CT imaging on the RefleXion system. This information will be used in the future to improve planning and delivery of radiotherapy that will target (in real time) the signal released from the [18F]-FDG-PET-CT tracer. Comparing the imaging from the standard of care [18F]-FDG-PET-CT with the [18F]-FDG imaging from RMRS may help improve the quality of the imaging captured and determine if imaging can be done on the RMRS at the same time as planning for radiation therapy, which would reduce the number of scans needed to plan for radiation for cancer.
Studienübersicht
Status
Detaillierte Beschreibung
PRIMARY OBJECTIVE:
I. To assess imaging performance of the [18F]-FDG PET-CT subsystem on the X1 RMRS to detect lesions (primary and metastatic) in patients with various types of malignancies.
SECONDARY OBJECTIVE:
I. To determine the feasibility of generating a BgRT plan using X1 RMRS-acquired [18F]-FDG PET data derived from the imaging-only session at the studied dose level.
OUTLINE:
Patients receive [18F]-FDG injection and undergo SOC [18F]-FDG PET-CT on study. Patients with at least one PET avid lesion then undergo X1 RMRS PET-CT imaging-only session on study.
Studientyp
Einschreibung (Geschätzt)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
California
-
Duarte, California, Vereinigte Staaten, 91010
- City of Hope Medical Center
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Documented informed consent of the participant and/or legally authorized representative
- Age: >= 21 years
- Patients with malignancies (abdominal/pelvic/thoracic/head and neck/breast tumors) undergoing SOC [18F]-FDG PET-CT for diagnostic and/or radiotherapy planning purposes
- Patients should be scheduled for [18F]-FDG PET-CT prior to study entry
Exclusion Criteria:
- Known psychiatric or substance abuse disorder that would interfere with conduct of the study
- Patient weight exceeding the weight limit (450 pounds) outlined per X1 RMRS specifications sheet
- Lung parenchymal and bone tumors will be excluded as their imaging characteristics were evaluated in a previous study
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Machbarkeit des Geräts
- Zuteilung: N / A
- Interventionsmodell: Einzelgruppenzuweisung
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Experimental: Device ([18F]-FDG PET-CT, X1 RMRS PET-CT)
Patients receive [18F]-FDG injection and undergo SOC [18F]-FDG PET-CT on study. Patients with at least one PET avid lesion then undergo X1 RMRS PET-CT imaging-only session on study. |
Undergo [18F]-FDG PET-CT
Andere Namen:
Given via injection
Andere Namen:
Undergo X1 RMRS PET-CT Undergo [18F]-FDG PET-CT
Andere Namen:
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Imaging performance of X1 RefleXion Medical Radiotherapy System (RMRS) positron emission tomography (PET)-computed tomography (CT) with the Imaging performance of the diagnostic fludeoxyglucose F-18 ([18F]-FDG) PET-CT
Zeitfenster: Up to 72 hours
|
One key metric will be the percent of patients with lesions identified on standard of care (SOC) PET-CT that are not identified on X1 (false negatives if considering SOC the true standard). For the SOC [18F]-FDG PET-CT, the maximum standard uptake value (SUV) and the greatest dimension in centimeters will be recorded for each PET avid malignant lesion identified by the nuclear medicine radiologist. The patient's radiation oncologist will interpret the X1 PET scan for the same metrics. Graphical presentations will be provided to compare SOC positive lesions and X1 positive lesions, and SOC positive lesions and X1 negative lesions with regards to lesion size, lesion location (lymph nodes, soft tissue, visceral organ) and SUV uptake. Descriptive statistics will be utilized to quantify results. Mean, standard deviation, interquartile range (IQR), and range will be reported for each continuous variable. Frequency and percentage will be reported for categorical variables. |
Up to 72 hours
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Percent of cases where X1 RMRS PET data can be used to generate an acceptable biology-guided radiotherapy (BgRT) plan
Zeitfenster: Up to 72 hours
|
The true positive lesions identified on the X1 PET images will be identified and used for BgRT planning. Simulated planning using the RefleXion treatment planning software will be performed, and the radiation dose to organs at risk calculated. Principal investigator will determine whether this plan is acceptable or not. The percent of cases in which RefleXion [18F]-FDG PET data led to an acceptable plan will be recorded (descriptive statistics). Descriptive statistics will be utilized to quantify results. Mean, standard deviation, IQR, and range will be reported for each continuous variable. Frequency and percentage will be reported for categorical variables. |
Up to 72 hours
|
Mitarbeiter und Ermittler
Sponsor
Mitarbeiter
Ermittler
- Hauptermittler: Jeffrey Y Wong, City of Hope Medical Center
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Geschätzt)
Studienabschluss (Geschätzt)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Zusätzliche relevante MeSH-Bedingungen
- Diagnosetechniken und Verfahren
- Diagnose
- Kohlenhydrate
- Tomographie
- Diagnostische Bildgebung
- Desoxyglucose
- Desoxyzucker
- Bildinterpretation, computergestützt
- Bildverbesserung
- Fotografie
- Tomographie, Emissionskomput
- Radionuklidbildgebung
- Diagnosetechniken, Radioisotop
- Fluordesoxyglucose F18
- Positron-Emissionstomographie
Andere Studien-ID-Nummern
- 22668
- P30CA033572 (US NIH Stipendium/Vertrag)
- 22668 (Andere Kennung: City of Hope Comprehensive Cancer Center)
- NCI-2023-01994 (Registrierungskennung: CTRP (Clinical Trial Reporting Program))
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .