- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT05844306
Performances de l'imagerie TEP/CT RefleXion chez les patients atteints de diverses tumeurs malignes
Une étude prospective pilote sur les performances d'imagerie du sous-système RefleXion [18F]-FDG PET-CT chez des patients atteints de diverses tumeurs malignes
This clinical trial examines RefleXion Medical Radiotherapy System (RMRS) imaging to the standard of care (SOC) fludeoxyglucose F-18 ([18F]-FDG)- positron emission tomography (PET)-computed tomography (CT) imaging in patients with various cancers (malignancies). PET is an established imaging technique that utilizes small amounts of radioactivity attached to very minimal amounts of tracer, in the case of this research, [18F]-FDG. Because some cancers take up [18F]-FDG, cancer cells can be seen with PET. CT utilizes x-rays that traverse body from the outside. CT images provide an exact outline of organs and potential inflammatory tissue where it occurs in patient's body. The RefleXion system is designed to facilitate delivery of biology-guided radiotherapy (BgRT). The RMRS uses PET emissions to guide radiotherapy delivery in real-time and has been studied for use with FDG (which is an agent used in standard PET-CT scans that targets glucose). Information gathered from this study may help researchers to improve PET-CT imaging on the RefleXion system. This information will be used in the future to improve planning and delivery of radiotherapy that will target (in real time) the signal released from the [18F]-FDG-PET-CT tracer. Comparing the imaging from the standard of care [18F]-FDG-PET-CT with the [18F]-FDG imaging from RMRS may help improve the quality of the imaging captured and determine if imaging can be done on the RMRS at the same time as planning for radiation therapy, which would reduce the number of scans needed to plan for radiation for cancer.
Aperçu de l'étude
Statut
Description détaillée
PRIMARY OBJECTIVE:
I. To assess imaging performance of the [18F]-FDG PET-CT subsystem on the X1 RMRS to detect lesions (primary and metastatic) in patients with various types of malignancies.
SECONDARY OBJECTIVE:
I. To determine the feasibility of generating a BgRT plan using X1 RMRS-acquired [18F]-FDG PET data derived from the imaging-only session at the studied dose level.
OUTLINE:
Patients receive [18F]-FDG injection and undergo SOC [18F]-FDG PET-CT on study. Patients with at least one PET avid lesion then undergo X1 RMRS PET-CT imaging-only session on study.
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
California
-
Duarte, California, États-Unis, 91010
- City of Hope Medical Center
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Documented informed consent of the participant and/or legally authorized representative
- Age: >= 21 years
- Patients with malignancies (abdominal/pelvic/thoracic/head and neck/breast tumors) undergoing SOC [18F]-FDG PET-CT for diagnostic and/or radiotherapy planning purposes
- Patients should be scheduled for [18F]-FDG PET-CT prior to study entry
Exclusion Criteria:
- Known psychiatric or substance abuse disorder that would interfere with conduct of the study
- Patient weight exceeding the weight limit (450 pounds) outlined per X1 RMRS specifications sheet
- Lung parenchymal and bone tumors will be excluded as their imaging characteristics were evaluated in a previous study
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Faisabilité de l'appareil
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Device ([18F]-FDG PET-CT, X1 RMRS PET-CT)
Patients receive [18F]-FDG injection and undergo SOC [18F]-FDG PET-CT on study. Patients with at least one PET avid lesion then undergo X1 RMRS PET-CT imaging-only session on study. |
Undergo [18F]-FDG PET-CT
Autres noms:
Given via injection
Autres noms:
Undergo X1 RMRS PET-CT Undergo [18F]-FDG PET-CT
Autres noms:
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Imaging performance of X1 RefleXion Medical Radiotherapy System (RMRS) positron emission tomography (PET)-computed tomography (CT) with the Imaging performance of the diagnostic fludeoxyglucose F-18 ([18F]-FDG) PET-CT
Délai: Up to 72 hours
|
One key metric will be the percent of patients with lesions identified on standard of care (SOC) PET-CT that are not identified on X1 (false negatives if considering SOC the true standard). For the SOC [18F]-FDG PET-CT, the maximum standard uptake value (SUV) and the greatest dimension in centimeters will be recorded for each PET avid malignant lesion identified by the nuclear medicine radiologist. The patient's radiation oncologist will interpret the X1 PET scan for the same metrics. Graphical presentations will be provided to compare SOC positive lesions and X1 positive lesions, and SOC positive lesions and X1 negative lesions with regards to lesion size, lesion location (lymph nodes, soft tissue, visceral organ) and SUV uptake. Descriptive statistics will be utilized to quantify results. Mean, standard deviation, interquartile range (IQR), and range will be reported for each continuous variable. Frequency and percentage will be reported for categorical variables. |
Up to 72 hours
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Percent of cases where X1 RMRS PET data can be used to generate an acceptable biology-guided radiotherapy (BgRT) plan
Délai: Up to 72 hours
|
The true positive lesions identified on the X1 PET images will be identified and used for BgRT planning. Simulated planning using the RefleXion treatment planning software will be performed, and the radiation dose to organs at risk calculated. Principal investigator will determine whether this plan is acceptable or not. The percent of cases in which RefleXion [18F]-FDG PET data led to an acceptable plan will be recorded (descriptive statistics). Descriptive statistics will be utilized to quantify results. Mean, standard deviation, IQR, and range will be reported for each continuous variable. Frequency and percentage will be reported for categorical variables. |
Up to 72 hours
|
Collaborateurs et enquêteurs
Parrainer
Collaborateurs
Les enquêteurs
- Chercheur principal: Jeffrey Y Wong, City of Hope Medical Center
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
- Techniques et procédures de diagnostic
- Diagnostic
- Glucides
- Tomographie
- Imagerie diagnostique
- Désoxyglucose
- Sucres désoxy
- Interprétation d'image, assistée par ordinateur
- Amélioration de l'image
- Photographie
- Tomographie, émission composée
- Imagerie par radionucléide
- Techniques de diagnostic, radio-isotope
- Fluorodésoxyglucose F18
- Tomographie par émission de positrons
Autres numéros d'identification d'étude
- 22668
- P30CA033572 (Subvention/contrat des NIH des États-Unis)
- 22668 (Autre identifiant: City of Hope Comprehensive Cancer Center)
- NCI-2023-01994 (Identificateur de registre: CTRP (Clinical Trial Reporting Program))
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .