Tämä sivu käännettiin automaattisesti, eikä käännösten tarkkuutta voida taata. Katso englanninkielinen versio lähdetekstiä varten.

Clinical Evaluation Of Class I Composite Resin Restorations Using Three Different Adhesive Systems

perjantai 9. lokakuuta 2020 päivittänyt: Nazire Nurdan Çakır, Nuh Naci Yazgan University

Erciyes University Clinical Research Ethics Committee

Nowadays, most composite resins require the use of an adhesive material prior to application. For this purpose, etch & rinse (ER) and self-etch (SE) systems have been used for many years. While many in-vitro studies have been conducted in the literature comparing three adhesive systems, the number of clinical studies is less and inadequate. Therefore, the aim of this study was to investigate the effect of 3 different adhesive systems commonly used in clinics on the success of class I composite restorations using the criteria of the World Dental Federation (FDI) and the United States Public Health Service (USPHS).

Tutkimuksen yleiskatsaus

Tila

Valmis

Yksityiskohtainen kuvaus

Nowadays, most composite resins require the use of an adhesive material prior to application. For this purpose, etch & rinse (ER) and self-etch (SE) systems have been used for many years. Compared to SE systems, which are simplified and very easy to use, requiring less technical precision, traditional ER systems are still very popular and preferred by dentists. However, current researchers indicate that ER systems are more effective on enamel than dentin and that this effect is better than SE systems. SE systems are approaches in which the acid application and washing step are eliminated clinically and the possibility of making mistakes during the application and manipulation is reduced. An important advantage of these systems is that demineralization and resin infiltration occurs at the same time. Clinically, the application times are shorter than traditional systems. Two-steps SE systems have been used for a long time. In this system, the need for a separate acidic primer application has needed clinicians reason to search for single-steps bonding agents. And, in recent years, single-step SE systems also called "all in one", have been developed that include all steps of pickling, primer application, and adhesive agent application. However, there are studies showing that these systems do not perform as well as two-step SE systems. While many in-vitro studies have been conducted in the literature comparing three adhesive systems, the number of clinical studies is less and inadequate. Therefore, the aim of this study was to investigate the effect of 3 different adhesive systems commonly used in clinics on the success of class I composite restorations using the criteria of the World Dental Federation (FDI) and the United States Public Health Service (USPHS).

Opintotyyppi

Interventio

Ilmoittautuminen (Todellinen)

78

Vaihe

  • Ei sovellettavissa

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

14 vuotta - 18 vuotta (Aikuinen)

Hyväksyy terveitä vapaaehtoisia

Ei

Sukupuolet, jotka voivat opiskella

Kaikki

Kuvaus

Inclusion Criteria:

  • At least 3 Class-I caries lesions
  • Good health
  • Acceptable level of oral hygiene

Exclusion Criteria:

  • Did not have four caries lesions at least
  • Did not have Class-II caries lesions
  • Deep caries reaching the pulp
  • The patients are not 18-22 years old
  • Bruxism
  • Periodontal disease
  • Refused to participate

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Diagnostiikka
  • Jako: Satunnaistettu
  • Inventiomalli: Rinnakkaistehtävä
  • Naamiointi: Kolminkertaistaa

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Active Comparator: Single Bond 2
Single Bond 2 is a traditional etch and rinse adhesive system. It is used to bond the composite resin to the dental tissues. It was applied to the cavities opened in accordance with the manufacturer's instructions.
It is used to bond the composite resin to the dental tissues. That is, it is used to bond dental filling materials to dental tissues.
Active Comparator: Clearfil SE Bond
Clearfil SE bond is traditional two step self-etch adhesive system. It is used to bond the composite resin to the dental tissues. It was applied to the cavities opened in accordance with the manufacturer's instructions.
It is used to bond the composite resin to the dental tissues. That is, it is used to bond dental filling materials to dental tissues.
Active Comparator: Tri-S Bond
Tri-S bond is traditional one step self-etch adhesive system. It is used to bond the composite resin to the dental tissues. It was applied to the cavities opened in accordance with the manufacturer's instructions.
It is used to bond the composite resin to the dental tissues. That is, it is used to bond dental filling materials to dental tissues.

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Clinical Evaluation Of Class I Composite Resin Restorations Using Three Different Adhesive Systems with FDI and USPHS criteria
Aikaikkuna: One years
FDI; World Dental Federation USPHS; United States Public Health Service. Two calibrated observers who were blinded to the objective of this study performed the evaluations.
One years
Clinical Evaluation Of Class I Composite Resin Restorations Using Three Different Adhesive Systems with FDI and USPHS criteria
Aikaikkuna: Two years
FDI; World Dental Federation USPHS; United States Public Health Service. Two calibrated observers who were blinded to the objective of this study performed the evaluations.
Two years

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Tutkijat

  • Päätutkija: Nazire Nurdan Çakır, Nuh Naci Yazgan University

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Todellinen)

Maanantai 1. helmikuuta 2016

Ensisijainen valmistuminen (Todellinen)

Torstai 1. helmikuuta 2018

Opintojen valmistuminen (Todellinen)

Sunnuntai 1. huhtikuuta 2018

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Lauantai 3. lokakuuta 2020

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Perjantai 9. lokakuuta 2020

Ensimmäinen Lähetetty (Todellinen)

Maanantai 19. lokakuuta 2020

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Maanantai 19. lokakuuta 2020

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Perjantai 9. lokakuuta 2020

Viimeksi vahvistettu

Torstai 1. lokakuuta 2020

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Yksittäisten osallistujien tietojen suunnitelma (IPD)

Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?

Päättämätön

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Kliiniset tutkimukset Hammasliimamateriaalit

Kliiniset tutkimukset Dental adhesive materials.

Tilaa