Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Clinical Evaluation Of Class I Composite Resin Restorations Using Three Different Adhesive Systems

9. Oktober 2020 aktualisiert von: Nazire Nurdan Çakır, Nuh Naci Yazgan University

Erciyes University Clinical Research Ethics Committee

Nowadays, most composite resins require the use of an adhesive material prior to application. For this purpose, etch & rinse (ER) and self-etch (SE) systems have been used for many years. While many in-vitro studies have been conducted in the literature comparing three adhesive systems, the number of clinical studies is less and inadequate. Therefore, the aim of this study was to investigate the effect of 3 different adhesive systems commonly used in clinics on the success of class I composite restorations using the criteria of the World Dental Federation (FDI) and the United States Public Health Service (USPHS).

Studienübersicht

Status

Abgeschlossen

Intervention / Behandlung

Detaillierte Beschreibung

Nowadays, most composite resins require the use of an adhesive material prior to application. For this purpose, etch & rinse (ER) and self-etch (SE) systems have been used for many years. Compared to SE systems, which are simplified and very easy to use, requiring less technical precision, traditional ER systems are still very popular and preferred by dentists. However, current researchers indicate that ER systems are more effective on enamel than dentin and that this effect is better than SE systems. SE systems are approaches in which the acid application and washing step are eliminated clinically and the possibility of making mistakes during the application and manipulation is reduced. An important advantage of these systems is that demineralization and resin infiltration occurs at the same time. Clinically, the application times are shorter than traditional systems. Two-steps SE systems have been used for a long time. In this system, the need for a separate acidic primer application has needed clinicians reason to search for single-steps bonding agents. And, in recent years, single-step SE systems also called "all in one", have been developed that include all steps of pickling, primer application, and adhesive agent application. However, there are studies showing that these systems do not perform as well as two-step SE systems. While many in-vitro studies have been conducted in the literature comparing three adhesive systems, the number of clinical studies is less and inadequate. Therefore, the aim of this study was to investigate the effect of 3 different adhesive systems commonly used in clinics on the success of class I composite restorations using the criteria of the World Dental Federation (FDI) and the United States Public Health Service (USPHS).

Studientyp

Interventionell

Einschreibung (Tatsächlich)

78

Phase

  • Unzutreffend

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

16 Jahre bis 20 Jahre (Erwachsene)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • At least 3 Class-I caries lesions
  • Good health
  • Acceptable level of oral hygiene

Exclusion Criteria:

  • Did not have four caries lesions at least
  • Did not have Class-II caries lesions
  • Deep caries reaching the pulp
  • The patients are not 18-22 years old
  • Bruxism
  • Periodontal disease
  • Refused to participate

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Diagnose
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Verdreifachen

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Aktiver Komparator: Single Bond 2
Single Bond 2 is a traditional etch and rinse adhesive system. It is used to bond the composite resin to the dental tissues. It was applied to the cavities opened in accordance with the manufacturer's instructions.
It is used to bond the composite resin to the dental tissues. That is, it is used to bond dental filling materials to dental tissues.
Aktiver Komparator: Clearfil SE Bond
Clearfil SE bond is traditional two step self-etch adhesive system. It is used to bond the composite resin to the dental tissues. It was applied to the cavities opened in accordance with the manufacturer's instructions.
It is used to bond the composite resin to the dental tissues. That is, it is used to bond dental filling materials to dental tissues.
Aktiver Komparator: Tri-S Bond
Tri-S bond is traditional one step self-etch adhesive system. It is used to bond the composite resin to the dental tissues. It was applied to the cavities opened in accordance with the manufacturer's instructions.
It is used to bond the composite resin to the dental tissues. That is, it is used to bond dental filling materials to dental tissues.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Clinical Evaluation Of Class I Composite Resin Restorations Using Three Different Adhesive Systems with FDI and USPHS criteria
Zeitfenster: One years
FDI; World Dental Federation USPHS; United States Public Health Service. Two calibrated observers who were blinded to the objective of this study performed the evaluations.
One years
Clinical Evaluation Of Class I Composite Resin Restorations Using Three Different Adhesive Systems with FDI and USPHS criteria
Zeitfenster: Two years
FDI; World Dental Federation USPHS; United States Public Health Service. Two calibrated observers who were blinded to the objective of this study performed the evaluations.
Two years

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Ermittler

  • Hauptermittler: Nazire Nurdan Çakır, Nuh Naci Yazgan University

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

1. Februar 2016

Primärer Abschluss (Tatsächlich)

1. Februar 2018

Studienabschluss (Tatsächlich)

1. April 2018

Studienanmeldedaten

Zuerst eingereicht

3. Oktober 2020

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

9. Oktober 2020

Zuerst gepostet (Tatsächlich)

19. Oktober 2020

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

19. Oktober 2020

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

9. Oktober 2020

Zuletzt verifiziert

1. Oktober 2020

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • 5930

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

Unentschieden

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur Dental Adhesive Materials

Klinische Studien zur Dental adhesive materials.

3
Abonnieren