5 Years Long Term Results After Standalone CyPass-Implantation
Retro- and Prospective Monocentric Study to Evaluate the Safety and Effectiveness of the CyPass Stent 5 Years After Implantation
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Tipo di studio
Iscrizione (Effettivo)
Contatti e Sedi
Luoghi di studio
-
-
Mecklenburg/Vorpommern
-
Neubrandenburg, Mecklenburg/Vorpommern, Germania, 17036
- Dietrich-Bonhoeffer-Klinikum
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
- Bambino
- Adulto
- Adulto più anziano
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- patients who have undergone a standalone cypass implantation at least 3 years ago
- signed inform consent
Exclusion Criteria:
- Patients with too much travel distance between study center and home
- Patients who cannot visit the studycenter due to health problems
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Coorti e interventi
Gruppo / Coorte |
Intervento / Trattamento |
|---|---|
|
standalone CyPass implantation
patients who have undergone a standalone cypass implantation without cataract surgery more than 3 years ago
|
Heidelberg Retinal Topography, Visual field, intraocular pressure, medication anamnesis, Retinal Nerve Fibre Layer Thickness, Pachymetry, Sonography, full ophthalmological examination
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Number of Patients That Achieve Target Intraocular Pressure Measured in mmHg
Lasso di tempo: up to 7 years
|
The Measurement of the intraocular Pressure is a criterion for the Efficacy of CyPass Stent Procedure (success rate).
The postoperative target pressure of 15 mmHg, 18 mmHg or 21 mmHg (depends on Glaucoma Status) has to be achieved.
|
up to 7 years
|
|
Change of Intraocular Pressure in mmHg Preoperatively (at Screening) vs Postoperatively (at Final Examination)
Lasso di tempo: up to 7 years
|
The Measurement of the intraocular Pressure change is a criterion for the Efficacy of CyPass Stent Procedure (success rate). The postoperative pressure after 5 to 7 years has to be compared with the preoperative intraocular pressure (in mmHg) The change was calculated only from two time points. (value at the final examination time point minus the value at the preoperative time point |
up to 7 years
|
|
Number of Additional Medication
Lasso di tempo: up to 7 years
|
The number of additional Glaucoma medication is another criterion to determine the Efficacy of CyPass Stent Procedure (success rate). Up to 4 different active substance can be used to reduce the pressure. The more substances the patient uses postoperatively the lower is the success after implantation of the CyPass-Stent. The postoperative number of medications after 5 years has to be compared with the preoperative number |
up to 7 years
|
|
Number of Participants With Secondary Glaucoma Procedures
Lasso di tempo: up to 7 years
|
To determine the efficacy of CyPass Stent procedure completely the number of secondary glaucoma interventions (surgery/ laser) has to be documented
|
up to 7 years
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Number of Participants With Stability of Optic Nerve
Lasso di tempo: up to 7 years
|
The Measurement of the optic nerve (HRT) in comparison to the baseline is needed to evaluate the glaucoma damage and to determine the Longterm success rate and the safety of the CyPass- Stent-Procedure. With papillary tomography you can see the changes in the optic nerve head concerning the permanent failures of retinal vessels , measure them very precisely and compare them with the previous findings. |
up to 7 years
|
|
Number of Participants With Stability of the Retinal Nerve Fiber Layer Thickness
Lasso di tempo: up to 7 years
|
The comparison of the preoperative and postoperative Status of the Retinal Nerve Fiber Layer Thickness and retinal fundus thickness is another criterion to determine the absolute and relative success.
|
up to 7 years
|
|
Number of Participants With Stability of Visual Field
Lasso di tempo: up to 7 years
|
The parameter of the Visual Field (Mean Deviation) will be measured to evaluate the Safety of the CyPass-Procedure.
The visual Field shows the progression of glaucoma defects concerning failures in different parts for example in the center or in the periphery of the visual field.
|
up to 7 years
|
|
Number of Participants With Stability of Stent Position
Lasso di tempo: up to 7 years
|
Determination of Stent Position in the angle will be performed to exclude moving of the Stent.
The stent could change it's position forward into the anterior chamber or backwards in the suprachorioidal space
|
up to 7 years
|
|
Number of Participants With Stability of Stent Tissue Interaction
Lasso di tempo: up to 7 years
|
Determination of iris tissue reaction to the stent will be performed.
We document slight reaction without involving the opening, iris reaction with involving the opening and complete closure by tissue.
The iris Tissue could overgrow the opening of the stent and therfore the function of the stent is disturbed or even failed.
|
up to 7 years
|
|
Number of Participants With Intra-and Postoperative Complications
Lasso di tempo: up to 7 years
|
The number of intra-and postoperative complications are needed to evaluate the safety of the CyPass-procedure
|
up to 7 years
|
|
Number of Participants With Suprachoroidal Bleb
Lasso di tempo: up to 7 years
|
The Determination of the suprachoroidal bleb is needed to evaluate the function of the stent and the efficacy of the procedure.
The bigger the bleb, the lower the pressure and the better the efficacy of the stent
|
up to 7 years
|
Collaboratori e investigatori
Sponsor
Investigatori
- Investigatore principale: Helmut Hoeh, MD,FEBO, Department of Ophthalmology, Neubrandenburg, Germany
Pubblicazioni e link utili
Pubblicazioni generali
- Garcia-Feijoo J, Rau M, Grisanti S, Grisanti S, Hoh H, Erb C, Guguchkova P, Ahmed I, Grabner G, Reitsamer H, Shaarawy T, Ianchulev T. Supraciliary Micro-stent Implantation for Open-Angle Glaucoma Failing Topical Therapy: 1-Year Results of a Multicenter Study. Am J Ophthalmol. 2015 Jun;159(6):1075-1081.e1. doi: 10.1016/j.ajo.2015.02.018. Epub 2015 Mar 3.
- Hoeh H, Vold SD, Ahmed IK, Anton A, Rau M, Singh K, Chang DF, Shingleton BJ, Ianchulev T. Initial Clinical Experience With the CyPass Micro-Stent: Safety and Surgical Outcomes of a Novel Supraciliary Microstent. J Glaucoma. 2016 Jan;25(1):106-12. doi: 10.1097/IJG.0000000000000134.
- Grisanti S, Margolina E, Hoeh H, Rau M, Erb C, Kersten-Gomez I, Dick HB, Grisanti S. [Supraciliary microstent for open-angle glaucoma: clinical results of a prospective multicenter study]. Ophthalmologe. 2014 Jun;111(6):548-52. doi: 10.1007/s00347-013-2927-6. German.
- Hoh H, Grisanti S, Grisanti S, Rau M, Ianchulev S. Two-year clinical experience with the CyPass micro-stent: safety and surgical outcomes of a novel supraciliary micro-stent. Klin Monbl Augenheilkd. 2014 Apr;231(4):377-81. doi: 10.1055/s-0034-1368214. Epub 2014 Apr 25.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- STI 06/16
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
Periodo di condivisione IPD
Criteri di accesso alla condivisione IPD
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Glaucoma diagnostics
-
Medfield DiagnosticsCompletato
-
Mansoura UniversityCompletatoSoddisfazione del paziente | Risultati clinici | Complicanza protesicaEgitto
-
North Bristol NHS TrustEKF DiagnosticsRitiratoMisurazione del lattato nel sangue fetaleRegno Unito
-
MP Biomedicals, LLCMP Biomedicals Asia Pacific Pte. Ltd.CompletatoInfezioni da HTLV-I | Infezioni da HTLV-II | Virus T-linfotropo umano 1 | Virus T-linfotropo umano 2 | Linfoma leucemico a cellule T associato a HTLV I | Mielopatie associate a HTLV IStati Uniti
-
MP Biomedicals, LLCMP Biomedicals Asia Pacific Pte. Ltd.CompletatoInfezioni da HTLV-I | Infezioni da HTLV-II | Virus T-linfotropo umano 1 | Virus T-linfotropo umano 2 | Linfoma leucemico a cellule T associato a HTLV I | Mielopatie associate a HTLV IStati Uniti
-
Stanford UniversitySanta Clara Valley Medical CenterRitiratoSifilide congenita | Sifilide materna durante la gravidanza - Bambino non ancora partoritoStati Uniti
-
KU LeuvenCompletato
-
Haukeland University HospitalSiemens Corporation, Corporate TechnologyCompletato
-
Polish Society of Disaster MedicineAttivo, non reclutante
-
Center for Eye Research AustraliaNovartis PharmaceuticalsTerminatoDegenerazione maculare | Neovascolarizzazione coroidaleAustralia