Evaluation of Performance, Usability, and Reliability of a Novel Device for Continuous Collection of Physiological Data
A Study to Evaluate the Performance, Usability, and Reliability of a Novel Device for Continuous Collection of Physiological Data in Healthcare and Remote Settings
Study objective: The primary objective of the clinical investigation is to evaluate the accuracy of BioStamp nPoint system algorithm measurements.
Study design: A single-site, non-significant risk, open-label, prospective non-randomized clinical investigation designed to validate the accuracy of the various physiological parameters that the Wearable Sensor Patches acquire and the system processes.
Przegląd badań
Status
Warunki
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Ohio
-
Cincinnati, Ohio, Stany Zjednoczone, 45212
- CTI Clinical Research Center
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Male or female volunteers, at least 18 years of age at the time of screening visit;
- Fluent in English;
- The subject is willing to comply with the protocol specified evaluations;
- Subject is willing and cognitively able to sign informed consent
Exclusion Criteria:
- Pregnancy;
- Positive urine drug screen
- History of active (clinically significant) skin disorders;
- History of allergic response to silicones or adhesives;
- Subjects with electronic implants of any kind (e.g. pacemaker)
- History of sleep disorders or self-reported insomnia or other sleep conditions;
- Broken, damaged or irritated skin or rashes near the sensor application sites;
- Subjects that are MC10 employees or shareholders, or a spouse or child of an MC10 employee or shareholder;
- Subjects who are physically or cognitively unable to normally perform activities of daily living, assessed at the discretion of the investigator.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Inny
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Inny: Single Arm
This single arm consists of all subjects which will interact with the device under investigation as well as comparator devices. This includes the Physiological signal monitor intervention, Heart rate and heart rate variability comparison device intervention, Respiration rate comparison device intervention, and Activity classification intervention. |
Wireless remote monitoring system intended for use by researchers and healthcare professionals for continuous collection of physiological data in home and healthcare settings.
FDA cleared reference device that monitors heart rate and heart rate variability in subjects
FDA cleared reference device that monitors respiration rate in subjects
Visual annotation of subject posture and other activities used for reference
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Accuracy of Heart Rate Measured in Beats Per Minute Compared to Reference Device
Ramy czasowe: 2 days after informed consent
|
Heart rate as measured by the subject device in beats per minute will be compared to the reference device.
The Mean Absolute Error (MAE) between measurements from each device is presented.
|
2 days after informed consent
|
|
Accuracy of Heart Rate Variability Measured by Root Mean Square of Successive Differences (HRV RMSSD) Compared to the Reference Device
Ramy czasowe: 2 days after informed consent
|
Heart Rate Variability RMSSD is measured by the subject device determined by root mean square of successive differences in neighboring RR intervals and will be compared to the reference device.
The Mean Absolute Error (MAE) between measurements from each device is presented.
|
2 days after informed consent
|
|
Accuracy of Heart Rate Variability Measured by Low Frequency Content to High Frequency Content Ratio (HRV Ratio) Compared to the Reference Device
Ramy czasowe: 2 days after informed consent
|
HRV Ratio as measured by the subject device determined by low frequency content to high frequency content ratio (HRV Ratio) in beats per minute will be compared to the reference device.
The Mean Absolute Error (MAE) between measurements from each device is presented.
|
2 days after informed consent
|
|
Accuracy of Respiration Rate Measured in Breaths Per Minute Compared to the Reference Device
Ramy czasowe: 2 days after informed consent
|
Respiration rate as measured by the subject device in breaths per minute will be compared to the reference device.
The Mean Absolute Error (MAE) between measurements from each device is presented.
|
2 days after informed consent
|
|
Accuracy of Activity Classification as Compared to Visual Annotation
Ramy czasowe: 2 days after informed consent
|
The device under test will classify a subjects activity into sleeping, standing, sitting, lying, walking and other activities as the subject performs various predefined activities, which are annotated by an observer.
The device's Activity Classification will be compared to the observer's annotation.
The percentage of correct classifications by the device against indicated visual observation is presented.
The percent correct is not a per subject average, but is the percentage of all activity classifications which were correct when compared to ground truth observation.
|
2 days after informed consent
|
|
Accuracy of Step Count Compared to an Observer's Manual Count
Ramy czasowe: 2 days after informed consent
|
The number of steps reported by the device under test during a 6 minute walk test will be compared to an observer's manual count of the number of steps taken.
|
2 days after informed consent
|
|
Accuracy of Sleep Onset Time (Hours, Minutes, and Seconds), Sleep Wake Time (Hours, Minutes, and Seconds) as Compared to an Observer's Visual Annotation
Ramy czasowe: 2 days after informed consent
|
Sleep onset and wake times as reported by the device under test will be compared to an observer's visual annotation of the sleep onset and wake times.
The Mean Absolute Error (MAE) between times as indicated by the device and observed times is presented.
|
2 days after informed consent
|
|
Accuracy of Posture Classification as Compared to Visual Annotation
Ramy czasowe: 2 days after informed consent
|
The device under test will classify a subjects activity into sleep posture, standing posture, and sitting posture as the subject performs various predefined activities, which are annotated by an observer.
The device's Posture Classification will be compared to the observer's annotation.
The percentage of correct classifications by the device against indicated visual observation is presented.
The percent correct is not a per subject average, but is the percentage of all posture classifications which were correct when compared to ground truth observation.
|
2 days after informed consent
|
|
Number of Sensors That Remained Sufficiently Adhered to Subjects for 24 Hours as Assessed by a 5 Point Scale
Ramy czasowe: 2 days after informed consent
|
The level of sensor adhesion will be assessed by a 5 point scale (0- sensor is greater than or equal to 90% of sensor adhered, 4-sensor completely detached from subject).
Sensors receiving scores of 0 and 1 will be determined to have acceptable adhesion, while scores of 2, 3, and 4 will be considered unacceptable adhesion.
The percentage of sensors which had acceptable adhesion at sensor removal is presented.
|
2 days after informed consent
|
Współpracownicy i badacze
Sponsor
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Inne numery identyfikacyjne badania
- MC10-PTL-103
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
produkt wyprodukowany i wyeksportowany z USA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Physiological signal monitor
-
Bio-Signal Group Corp.National Institute of Neurological Disorders and Stroke (NINDS); State University... i inni współpracownicyZakończonyZmieniony stan psychicznyStany Zjednoczone
-
National Institute of Geriatrics, Rheumatology...RekrutacyjnyFibromialgia | Zespół chronicznego zmęczenia (CFS)Polska
-
Cairo UniversityZakończony
-
Weill Medical College of Cornell UniversityWeill Cornell Medical College in QatarWycofane
-
Stryker InstrumentsZakończonyZnieczulenie, generaleStany Zjednoczone
-
Mike O'Callaghan Military HospitalZakończonyCukrzyca typu IIStany Zjednoczone
-
Rush University Medical CenterNational Institute of Nursing Research (NINR); University of Illinois at Chicago i inni współpracownicyZakończonyAktywność fizycznaStany Zjednoczone
-
Malaghan Institute of Medical ResearchRekrutacyjnyChłoniak | Białaczka | Szpiczak | Zmiana Temperatury, Ciało | Nowotwory hematologiczneNowa Zelandia
-
University at BuffaloZakończonyZaburzenia rytmu serca, kołatanie serca, zawroty głowyStany Zjednoczone
-
Joslin Diabetes CenterAktywny, nie rekrutujący